Biopsy needle technique and the accuracy of diagnosis of atypical ductal hyperplasia for mammographic abnormalities

被引:0
|
作者
Zhao, L
Freimanis, R
Bergman, S
Shen, P
Perrier, ND
Lesko, N
Pulaski, T
Pulaski, S
Carr, JJ
Levine, EA
机构
[1] Wake Forest Univ, Surg Oncol Serv, Winston Salem, NC 27157 USA
[2] Wake Forest Univ, Breast Imaging Serv, Winston Salem, NC 27157 USA
[3] Wake Forest Univ, Dept Surg, Winston Salem, NC 27157 USA
[4] Wake Forest Univ, Dept Pathol & Radiol, Winston Salem, NC 27157 USA
关键词
D O I
暂无
中图分类号
R61 [外科手术学];
学科分类号
摘要
The evaluation of mammographic abnormalities has become a substantial effort for surgeons and radiologists. The vacuum-assisted core biopsy (VACB) has been touted as a more accurate tool for the evaluation of mammographic lesions. Diagnosis of atypical ductal hyperplasia (ADH) from a percutaneous needle biopsy of the breast is associated with a significant risk of missing a significant breast lesion. We compared 2 methods of sampling with stereotactic-guided breast biopsy, 14-gauge automated gun core biopsy (AGCB) and VACB, on the accuracy of diagnosis of ADH at a single institution. All cases of ADH, without associated malignancy, found via image-guided breast biopsy of nonpalpable lesions between March 1996 and April 2002 were evaluated. VACB biopsy needles were utilized between July 1998 to April 2002 (686 patients) and 14-gauge AGCB from March 1996 to June 1998 (350 patients). The results of these biopsies were reviewed and compared to surgical biopsy and pathological records. ADH alone was found in 53 cases (5.1% of biopsies; mean age 57.9 years). Of these, 39 patients with ADH subsequently underwent wire-localized excisional biopsy. The other 14 patients were observed. VACB biopsy understaged 7 of 29 (24%) patients with ADH (all of which were DCIS), AGCB understaged 4 of 10 cases (40%) with one being invasive. Of the patients in the core biopsy group who were initially followed, 2 developed significant lesions within 3 years of follow-up in the same quadrant of the breast. If these cases are added to the AGCB group, then 50 per cent were understaged and significantly more invasive lesions were understaged than with VACB (17% vs. 0%; P = 0.018). The VACB resulted in less understaging of ADH than AGCB. However, there remains a significant risk of missing DCIS in this setting even with the VACB. Furthermore, the risk of understaging an invasive lesion is significantly lower in this setting with a VACB than an AGCB. Although the risk of understaging ADH is lower with the VACB, we continue to recommend excisional biopsy in a good-risk patient when a diagnosis of ADH is rendered via VACB biopsy.
引用
收藏
页码:757 / 762
页数:6
相关论文
共 50 条
  • [41] Atypical ductal hyperplasia: Improved accuracy with the 11-gauge vacuum-assisted versus the 14-gauge core biopsy needle
    Sohn, V.
    Arthurs, Z.
    Eckert, M.
    Perry, J.
    Keylock, J.
    Brown, T.
    ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (02) : 39 - 39
  • [42] Atypical ductal hyperplasia: Improved accuracy with the 11-gauge vacuum-assisted versus the 14-gauge core biopsy needle
    Sohn, Vance
    Arthurs, Zachary
    Herbert, Garth
    Keylock, Joren
    Perry, Jason
    Eckert, Matthew
    Fellabaum, Dean
    Smith, Donald
    Brown, Tommy
    ANNALS OF SURGICAL ONCOLOGY, 2007, 14 (09) : 2497 - 2501
  • [43] Atypical Ductal Hyperplasia: Improved Accuracy with the 11-Gauge Vacuum-Assisted versus the 14-Gauge Core Biopsy Needle
    Vance Sohn
    Zachary Arthurs
    Garth Herbert
    Joren Keylock
    Jason Perry
    Matthew Eckert
    Dean Fellabaum
    Donald Smith
    Tommy Brown
    Annals of Surgical Oncology, 2007, 14 : 2497 - 2501
  • [44] Atypical ductal hyperplasia and ductal carcinoma in situ as revealed by large-core needle breast biopsy: Results of surgical excision
    Darling, MLR
    Smith, DN
    Lester, SC
    Kaelin, C
    Selland, DLG
    Denison, CM
    DiPiro, PJ
    Rose, DI
    Rhei, E
    Meyer, JE
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 175 (05) : 1341 - 1346
  • [45] Atypical hyperplasia in the era of stereotactic core needle biopsy
    Brown, TA
    Wall, JW
    Christensen, ED
    Smith, DV
    Holt, CA
    Carter, PL
    Patience, TH
    Babu, SS
    Williard, WC
    JOURNAL OF SURGICAL ONCOLOGY, 1998, 67 (03) : 168 - 173
  • [46] A prospective comparison of stereotaxic fine-needle aspiration versus stereotaxic core needle biopsy for the diagnosis of mammographic abnormalities
    Symmans, WF
    Weg, N
    Gross, J
    Cangiarella, JF
    Tata, M
    Mazzo, JA
    Waisman, J
    CANCER, 1999, 85 (05) : 1119 - 1132
  • [47] Tumortype, Nottingham grade, and survival following a diagnosis of atypical ductal hyperplasia on initial breast biopsy
    Sanders, M. E.
    Schuyler, P. A.
    Simpson, J. F.
    Dupont, W. D.
    Page, D. L.
    LABORATORY INVESTIGATION, 2007, 87 : 49A - 50A
  • [48] Risk of Breast Cancer in Women Observed after Core Biopsy Diagnosis of Atypical Ductal Hyperplasia
    Ganesan, N.
    Bevers, T. B.
    Ying, J.
    Coyne, R.
    Lane, D.
    Albarracin, C.
    Bedrosian, I.
    ANNALS OF SURGICAL ONCOLOGY, 2014, 21 : S50 - S50
  • [49] Atypical ductal hyperplasia bordering on DCIS on core biopsy is associated with higher risk of upgrade than conventional atypical ductal hyperplasia
    Pawloski, Kate R.
    Christian, Nicole
    Knezevic, Andrea
    Wen, Hannah Y.
    Van Zee, Kimberly J.
    Morrow, Monica
    Tadros, Audree B.
    BREAST CANCER RESEARCH AND TREATMENT, 2020, 184 (03) : 873 - 880
  • [50] Atypical ductal hyperplasia bordering on DCIS on core biopsy is associated with higher risk of upgrade than conventional atypical ductal hyperplasia
    Kate R. Pawloski
    Nicole Christian
    Andrea Knezevic
    Hannah Y. Wen
    Kimberly J. Van Zee
    Monica Morrow
    Audree B. Tadros
    Breast Cancer Research and Treatment, 2020, 184 : 873 - 880