The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

被引:12
|
作者
Park, Duck-Gun [1 ]
Angani, C. S. [2 ]
Kishore, M. B. [1 ,3 ]
Kim, C. G. [3 ]
Lee, D. H. [1 ]
机构
[1] Korea Atom Energy Res Inst, Nucl Mat Res Div, Taejon 305600, South Korea
[2] Indira Gandhi Ctr Atom Res, Kalpakkam 603102, Tamil Nadu, India
[3] Chungnam Natl Univ, Dept Mat Sci & Engn, Taejon 305764, South Korea
关键词
NDT; pulsed eddy current; lift-off effect; wall thinning; pipeline;
D O I
10.4283/JMAG.2012.17.4.298
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.
引用
收藏
页码:298 / 301
页数:4
相关论文
共 50 条
  • [41] Optimization of Flexible Eddy Current Patterns with Low Sensitivity to Lift-Off
    Decitre, Jean-Marc
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XX), 2017, 42 : 275 - 282
  • [42] Reduction of lift-off effect for pulsed eddy current NDT based on sensor design and frequency spectrum analysis
    Yang, Binfeng
    Li, Bin
    Wang, Yunjiang
    NONDESTRUCTIVE TESTING AND EVALUATION, 2010, 25 (01) : 77 - 89
  • [43] Pulsed eddy current characterization of local wall-thinning
    Cheng, Weiying
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2014, 45 (1-4) : 179 - 184
  • [44] Evaluation of Lift-Off Effect on Metal Testing with Non-Conductive Coating by Using Eddy Current Testing Technique
    Harun, Syafiqa Putri Adlina
    Sulaiman, Fauziah
    JURNAL FIZIK MALAYSIA, 2024, 45 (01): : 10028 - 10038
  • [45] Measurement of wall thinning through insulation with ferromagnetic cladding using pulsed eddy current testing
    Xu, Zhiyuan
    Wu, Xinjun
    Huang, Chen
    Kang, Yihua
    ADVANCED MEASUREMENT AND TEST, PTS 1-3, 2011, 301-303 : 426 - 429
  • [46] Development of a very fast simulator for pulsed eddy current testing signals of local wall thinning
    Xie, Shejuan
    Chen, Zhenmao
    Takagi, Toshiyuki
    Uchimoto, Tetsuya
    NDT & E INTERNATIONAL, 2012, 51 : 45 - 50
  • [47] Evaluation of Coating Thickness Using Lift-Off Insensitivity of Eddy Current Sensor
    Meng, Xiaobai
    Lu, Mingyang
    Yin, Wuliang
    Bennecer, Abdeldjalil
    Kirk, Katherine J.
    SENSORS, 2021, 21 (02) : 1 - 18
  • [48] Lift-off effect in high-frequency eddy current conductivity spectroscopy
    Abu-Nabah, Bassam A.
    Nagy, Peter B.
    NDT & E INTERNATIONAL, 2007, 40 (08) : 555 - 565
  • [49] Lift-Off Effect of Koch and Circular Differential Pickup Eddy Current Probes
    Guolong Chen
    Zheng Cao
    Shuaishuai Zhang
    Ji Wei
    Wei Gao
    Wuyin Jin
    ChineseJournalofMechanicalEngineering, 2024, 37 (02) : 300 - 310
  • [50] Lift-Off Effect of Koch and Circular Differential Pickup Eddy Current Probes
    Chen, Guolong
    Cao, Zheng
    Zhang, Shuaishuai
    Wei, Ji
    Gao, Wei
    Jin, Wuyin
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2024, 37 (01)