Modelling Air Compressibility in OWC Devices with Deformable Air Chambers

被引:5
|
作者
Benreguig, Pierre [1 ]
Murphy, Jimmy [1 ]
机构
[1] Univ Coll Cork, MaREI Ctr, Beaufort Bldg,Haubowline Rd, Ringaskiddy P43 C573, Cork, Ireland
关键词
wave energy; oscillating water column; air compressibility; tank testing; closed-circuit; non-return valves; spring-like effect; deformable chambers; FLOW;
D O I
10.3390/jmse7080268
中图分类号
U6 [水路运输]; P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Air compressibility effects play an important role in large-scale Oscillating Water Column (OWC) wave energy converters. Air compressibility is however not scalable with Froude similarity law. An existing scaling method enables correctly reproducing the air compressibility at the model scale, but its implementation is effortful and becomes cumbersome for floating devices and tests at relatively large scales (1/15(th)-1/2(th)). Air compressibility is therefore commonly ignored in model-scale tank testing of conventional OWC devices, which can lead to substantially unrealistic results on the device performance relative to the full-scale device. In the case of the Tupperwave device, which is a closed circuit OWC device, correctly modelling air compressibility during tank testing is however essential because the device relies on air compressibility to work. In this paper, a new method for modelling air compressibility at the model scale is presented. The method uses variable volume chambers, which mimic air compressibility by storing energy under the form of strain energy. This method reduces the difficulties of implementation and enhances the application of the existing method to larger scales. Various applications to this method are identified and described, including the presentation of a novel OWC concept.
引用
收藏
页数:13
相关论文
共 50 条
  • [31] Air conditioning systems: Testing air cleaning devices
    不详
    FILTRATION + SEPARATION, 2009, 46 (04) : 30 - +
  • [32] Air conditioning systems: Testing air cleaning devices
    Cao, Guoqing
    Zhang, Yizhao
    Filtration and Separation, 2009, 46 (04): : 32 - 33
  • [33] FLUIDIC AIR DEFLECTING DEVICES FOR AIR CONDITIONERS.
    Nawa, M.
    Takahashi, Y.
    Sugawara, N.
    Hanafusa, H.
    Fluidics quarterly, 1981, 13 (01): : 47 - 58
  • [34] Effect of partial blockage of air duct outlet on performance of OWC device
    S.Patel
    K.Ram
    M.Rafiuddin Ahmed
    Journal of Central South University, 2012, 19 (03) : 748 - 754
  • [35] Effect of partial blockage of air duct outlet on performance of OWC device
    S. Patel
    K. Ram
    M. Rafiuddin Ahmed
    Journal of Central South University, 2012, 19 : 748 - 754
  • [36] AIR SPARK CHAMBERS FOR THE REGISTRATION OF PARTICLE SHOWERS
    DAION, MI
    KLIMANOVA, LF
    SOVIET PHYSICS JETP-USSR, 1964, 18 (05): : 1425 - 1426
  • [37] Calibration of ionization chambers in air kerma length
    Bochud, FO
    Grecescu, M
    Valley, JF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (09): : 2477 - 2487
  • [38] AIR TEMPERATURE CONTROL IN NITROGEN VOLATILIZATION CHAMBERS
    HOULT, EH
    BARLOW, EWR
    MCGARITY, JW
    PLANT AND SOIL, 1974, 40 (02) : 413 - 416
  • [39] AIR AND WATER CONSERVATION CHAMBERS OF CHEMICAL LABORATORIES
    不详
    SUOMEN KEMISTILEHTI, 1970, 43 (09): : 194 - &
  • [40] ANIMAL EXPOSURE CHAMBERS IN AIR POLLUTION STUDIES
    HINNERS, RG
    BURKART, JK
    CONTNER, GL
    ARCHIVES OF ENVIRONMENTAL HEALTH, 1966, 13 (05): : 609 - &