Electrochemical Behavior of Hydroquinone and Catechol at a Silsesquioxane-Modified Carbon Paste Electrode

被引:0
|
作者
da Silva, Paulo S. [1 ]
Gasparini, Bianca C. [1 ]
Magosso, Herica A. [1 ]
Spinelli, Almir [1 ]
机构
[1] Univ Fed Santa Catarina, Dept Quim, Grp Estudos Proc Eletroquim & Eletroanalit, BR-88040900 Florianopolis, SC, Brazil
关键词
modified carbon paste electrode; silsesquioxane; dihydroxybenzenes; electroanalysis; ADSORPTION; SIO2/AL2O3; OXIDATION;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A carbon paste electrode modified with 3-n-propyl-4-picolinium chloride silsesquioxane polymer was tested as a sensor for dihydroxybenzene isomers. The sensor showed excellent performance for simultaneous electroanalytical determination of hydroquinone and catechol. The calibration curves obtained were linear in the concentration range of 10.0 to 450.0 mu mol L-1 for hydroquinone = 0.998) and 10.0 to 300.0 mu mol L-1 for catechol = 0.997). The visual limit of detection was 10.0 mu mol L-1 for both isomers.
引用
收藏
页码:695 / 699
页数:5
相关论文
共 50 条
  • [31] Electrochemical behavior and simultaneous determination of catechol, resorcinol, and hydroquinone using thermally reduced carbon nano-fragment modified glassy carbon electrode
    Liu, Lingyu
    Ma, Zhen
    Zhu, Xiaohua
    Zeng, Ronghua
    Tie, Shaolong
    Nan, Junmin
    ANALYTICAL METHODS, 2016, 8 (03) : 605 - 613
  • [32] Simultaneous electrochemical detection of catechol and hydroquinone based on gold nanoparticles@carbon nanocages modified electrode
    Huang, Yi Hong
    Chen, Jian Hua
    Ling, Li Jing
    Su, Zhen Bo
    Sun, Xue
    Hu, Shi Rong
    Weng, Wen
    Huang, Yang
    Wu, Wen Bing
    He, Ya San
    ANALYST, 2015, 140 (23) : 7939 - 7947
  • [33] Direct simultaneous electrochemical determination of hydroquinone and catechol at a poly(glutamic acid) modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Bai, Junyue
    Wang, Hongjing
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (01): : 123 - 132
  • [34] Electrocatalytic response of hydroquinone and catechol at polyglycine modified glassy carbon electrode
    Wang, Liang
    Huang, Pengfei
    Wang, Hongjing
    Bai, Junyue
    Zhang, Liying
    Zhao, Yuqing
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (03): : 216 - 225
  • [35] Electrochemical behaviors of hydroquinone on a carbon paste electrode with ionic liquid as binder
    Key Laboratory of Eco-Chemical Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, China
    Bull. Korean Chem. Soc., 2008, 5 (915-920):
  • [36] Fabrication of voltammetric efficient sensor for catechol, hydroquinone and resorcinol at MgO modified pre-treated carbon paste electrode
    Chetankumar, K.
    Swamy, B. E. Kumara
    Sharma, S. C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 252 (252)
  • [37] Electrochemical behaviors of hydroquinone on a carbon paste electrode with ionic liquid as binder
    Sun, Wei
    Jiang, Qiang
    Yang, Maoxia
    Jiao, Kui
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2008, 29 (05) : 915 - 920
  • [38] Electrochemical behavior and determination of pyridoxine at chemically modified carbon paste electrode by electropolymerization
    K. P. Moulya
    J. G. Manjunatha
    Sameh M. Osman
    Santanu Patra
    Monatshefte für Chemie - Chemical Monthly, 2024, 155 : 551 - 559
  • [39] Electrochemical behavior of nicotinamide using carbon paste electrode modified with macrocyclic compounds
    Rahul M. Kotkar
    Ashwini K. Srivastava
    Journal of Inclusion Phenomena and Macrocyclic Chemistry, 2008, 60 : 271 - 279
  • [40] Electrochemical behavior and determination of pyridoxine at chemically modified carbon paste electrode by electropolymerization
    Moulya, K. P.
    Manjunatha, J. G.
    Osman, Sameh M.
    Patra, Santanu
    MONATSHEFTE FUR CHEMIE, 2024, 155 (06): : 551 - 559