Experimental and Numerical Analyses of Blind Bolted Momentresisting Composite Joints to CFST Columns with RC Slab

被引:3
|
作者
Wang, Jingfeng [1 ,2 ]
Pang, Yue [1 ]
机构
[1] Hefei Univ Technol, Sch Civil Engn, Hefei 230009, Anhui, Peoples R China
[2] Anhui Civil Engn Struct & Mat Lab, Hefei 230009, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
concrete-filled steel tube (CFST); composite joint; finite element analysis (FEA) model; end plate joint; blind bolt; END-PLATE JOINTS; EXPERIMENTAL BEHAVIOR; CFT COLUMN; SEISMIC PERFORMANCE; STEEL BEAM; CONCRETE; CONNECTIONS;
D O I
10.1007/s13296-017-9005-x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, experimental and numerical analyses were conducted to investigate the structural properties and failure modes of the blind bolted flush or extended end plate joints between concrete-filled steel tubular (CFST) columns and composite beams. The experimental program and the main results of the tests were elaborated. Four full-scale subassemblages beam-tocolumn exterior joints to hot-rolled and cold-formed CFST columns were tested. The failure modes and moment-rotation relation curves of the joints were evaluated. The test results showed that all specimens exhibited favorable strength and stiffness, and larger deformation capacities. Meanwhile, finite element analysis (FEA) modeling of the specimens was built and analyzed. The results obtained from the FEA modeling were satisfactory agreement with the experimental tests results. Then, an extensive parametric study was conducted to investigate the influence of various parameters on the moment capacity and rotation stiffness of composite joints under positive or negative moment. The experimental studies and numerical analyses can improve the design of the typed joints to be used in moment-resisting composite frames.
引用
收藏
页码:909 / 938
页数:30
相关论文
共 50 条
  • [31] On numerical modeling and tensile strength of bolted composite joints
    Liu, Xiangdong
    Li, Yazhi
    Li, Biao
    Hu, Bohai
    Xibei Gongye Daxue Xuebao/Journal of Northwestern Polytechnical University, 2013, 31 (06): : 878 - 883
  • [32] Experimental study of flush end plate beam-to-CFST column composite joints with deconstructable bolted shear connectors
    Ataei, Abdolreza
    Bradford, Mark A.
    Valipour, Hamid R.
    ENGINEERING STRUCTURES, 2015, 99 : 616 - 630
  • [33] NUMERICAL AND EXPERIMENTAL FAILURE ANALYSIS OF COMPOSITE LAMINATES WITH BOLTED JOINTS UNDER BENDING LOADS
    CHEN, WH
    LEE, SS
    JOURNAL OF COMPOSITE MATERIALS, 1995, 29 (01) : 15 - 36
  • [34] Fire performance of blind bolted composite beam to column joints
    Song, Tian-Yi
    Tao, Zhong
    Razzazzadeh, Ali
    Han, Lin-Hai
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2017, 132 : 29 - 42
  • [35] Experimental and numerical study on seismic behaviors of SRC column-RC slab joints in NPP
    Wang, Dayang
    Liu, Qiang
    Song, Yuanqi
    Zhu, Yong
    Zhang, Yongshan
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2025, 57 (02)
  • [36] Fire resistance of steel beam to square CFST column composite joints using RC slabs: Experiments and numerical studies
    Yang, You-Fu
    Fu, Feng
    FIRE SAFETY JOURNAL, 2019, 104 : 90 - 108
  • [37] A detailed experimental parametric analysis of bolted and hybrid bolted/bonded composite joints
    Li, Xin
    Xu, Bo
    Hong, Yang
    Luo, Haibo
    JOURNAL OF APPLIED POLYMER SCIENCE, 2023, 140 (05)
  • [38] Numerical model to simulate shear behaviour of RC joints and columns
    Shayanfar, J.
    Bengar, H. Akbarzadeh
    COMPUTERS AND CONCRETE, 2016, 18 (04): : 877 - 901
  • [39] Experimental and numerical analysis of the mechanical behavior of composite-to-titanium bolted joints with liquid shim
    Liu, L.
    Zhang, J.
    Chen, K.
    Wang, H.
    Liu, M.
    AEROSPACE SCIENCE AND TECHNOLOGY, 2016, 49 : 167 - 172
  • [40] Failure analysis of single lap composite laminate bolted joints: Comparison of experimental and numerical tests
    Montagne, Benoit
    Lachaud, Frederic
    Paroissien, Eric
    Martini, Dominique
    Congourdeau, Fabrice
    COMPOSITE STRUCTURES, 2020, 238