Steam flow measurement using alcohol tracers

被引:9
|
作者
Lovelock, BG [1 ]
机构
[1] Sinclair Knight Merz, Auckland, New Zealand
关键词
tracers alcohol; isopropanol; mass flow; chemistry;
D O I
10.1016/S0375-6505(01)00020-7
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Tracer flow testing procedures are increasingly being used for routine measurement of well output in operating geothermal fields. A new procedure developed in New Zealand uses low boiling-point, liquid alcohol (isopropanol or butan-2-ol) as the steam-phase tracer. The use of alcohol tracers allows major simplifications to field procedures, including injection with conventional liquid-dosing pumps, sampling into open sample bottles and preparation of composite steam/water tracers. These practical benefits far outweigh the only drawback of alcohol tracers, which is the need to correct for alcohol gas dissolved in the liquid phase. This paper reviews development work with alcohol tracers over the past five years and discusses the properties of alcohols and the practical aspects of their use in tracer-dilution testing. (C) 2001 Published by Elsevier Science Ltd on behalf of CNR.
引用
收藏
页码:641 / 654
页数:14
相关论文
共 50 条
  • [21] Using meters to measure steam flow
    Yoder, Jesse L.
    Plant Engineering (Barrington, Illinois), 1998, 52 (04):
  • [22] Measurement of steam flow rates using a clamp-on ultrasonic flowmeter with various wetness fractions
    Murakawa, Hideki
    Ichimura, Shuhei
    Sugimoto, Katsumi
    Asano, Hitoshi
    Umezawa, Shuichi
    Taira, Hirotoshi
    Ibi, Masayuki
    Akahane, Hajime
    FLOW MEASUREMENT AND INSTRUMENTATION, 2021, 80
  • [23] Measurement of tyre dust particles in the atmosphere using chemical tracers
    Harrison, Roy M.
    Alghamdi, Mansour A.
    ATMOSPHERIC ENVIRONMENT, 2023, 298
  • [24] DIRECT MEASUREMENT OF FRACTIONAL ABSORPTION USING STABLE ISOTOPIC TRACERS
    YERGEY, A
    VIEIRA, N
    COVELL, D
    FEDERATION PROCEEDINGS, 1987, 46 (03) : 880 - 880
  • [25] DIRECT MEASUREMENT OF FRACTIONAL ABSORPTION USING STABLE ISOTOPIC TRACERS
    YERGEY, AL
    COVELL, DG
    MUENZER, J
    VIEIRA, NE
    BONE, 1986, 7 (05) : 403 - 403
  • [26] Precise measurement of low diffusion coefficients using radioactive tracers
    Iijima, Y
    Nitta, H
    Nakamura, R
    Takasawa, K
    Inoue, A
    Takemoto, S
    Yamazaki, Y
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2005, 69 (04) : 321 - 331
  • [27] SIZE STEAM TRACERS QUICKLY .1.
    FOO, KW
    HYDROCARBON PROCESSING, 1994, 73 (01): : 93 - &
  • [28] SIZE STEAM TRACERS QUICKLY .2.
    FOO, KW
    HYDROCARBON PROCESSING, 1994, 73 (02): : 91 - 95
  • [29] Measurement of steam quality using a vortex flowmeter
    Dattarajan, Srinivasan
    Pali, Shishir
    Fernandes, Neville
    Gadwal, Narendra
    Hulwan, Dattatray
    FLOW MEASUREMENT AND INSTRUMENTATION, 2019, 65 : 227 - 232
  • [30] MEASUREMENT OF STEAM QUALITY USING A NEUTRON DENSITOMETER
    WAN, PT
    JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 1991, 30 (06): : 29 - 33