Highly sensitive electrochemical luminescence determination of thiamine

被引:28
|
作者
Zhang, CX [1 ]
Zhou, GJ
Zhang, ZJ
Aizawa, M
机构
[1] Shaanxi Normal Univ, Dept Chem, Xian 710062, Peoples R China
[2] Tokyo Inst Technol, Dept Bioengn, Yokohama, Kanagawa 2265801, Japan
基金
中国国家自然科学基金;
关键词
electrochemical luminescence; thiamine; rhodamine B; energy transfer;
D O I
10.1016/S0003-2670(99)00293-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive electrochemical luminescence (ECL) method has been developed for the determination of thiamine based on electrochemically oxidizing thiamine with rhodamine B as a sensitizer. A weak ECL signal of thiamine was electrochemically generated on a platinum electrode in an alkaline solution and strongly enhanced in the presence of rhodamine B. Under the condition of 0.10 mM rhodamine B, 6 mM CTMAB and 0.36 M sodium hydroxide, the response to the concentration of thiamine is linear range from 0.1 mu g ml(-1) to 2 mu g ml(-1) and a detection limit of 0.08 mu g ml(-1) can be achieved. This method has been successfully applied to the determination of thiamine in pharmaceutical preparations. The energy transfer ECL scheme is also postulated. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:165 / 170
页数:6
相关论文
共 50 条
  • [41] Highly sensitive electrochemical determination of neutrophil gelatinase-associated lipocalin for acute kidney injury
    Kannan, Palanisamy
    Tiong, Ho Yee
    Kim, Dong-Hwan
    BIOSENSORS & BIOELECTRONICS, 2012, 31 (01): : 32 - 36
  • [42] An epitope imprinted electrochemical sensor for highly sensitive and selective determination of prostate-specific antigen
    Shao, Huikai
    Zhao, Lingguo
    Liu, Zhenping
    Li, Jinqi
    MICROCHIMICA ACTA, 2024, 191 (11)
  • [43] Highly sensitive 3D gold nanotube ensembles: Application to electrochemical determination of metronidazole
    Mollamahale, Y. Bahari
    Ghorbani, Mohammad
    Ghalkhani, Masoumeh
    Vossoughi, Manouchehr
    Dolati, Abolghasem
    ELECTROCHIMICA ACTA, 2013, 106 : 288 - 292
  • [44] Disposable electrochemical sensor: Highly sensitive determination of nitrofurazone antibiotic in environmental samples and pharmaceutical formulations
    Silva F.W.L.
    Bernardino C.A.R.
    Ferreira J.H.A.
    Mahler C.F.
    Santelli R.E.
    Canevari T.C.
    Cincotto F.H.
    Chemosphere, 2024, 361
  • [45] Highly Sensitive Electrochemical Methyltransferase Activity Assay
    Deng, Huimin
    Yang, Xinjian
    Yeo, Stephanie Pei Xing
    Gao, Zhiqiang
    ANALYTICAL CHEMISTRY, 2014, 86 (04) : 2117 - 2123
  • [46] Highly sensitive electrochemical detection of alkaline phosphatase
    Ito, S
    Yamazaki, S
    Kano, K
    Ikeda, T
    ANALYTICA CHIMICA ACTA, 2000, 424 (01) : 57 - 63
  • [47] Highly sensitive electrochemical biosensors for water monitoring
    Chemnitius, G
    Meusel, M
    Zaborosch, C
    Knoll, M
    Spener, F
    Cammann, K
    FOOD TECHNOLOGY AND BIOTECHNOLOGY, 1996, 34 (01) : 23 - 29
  • [48] Highly sensitive, reusable electrochemical aptasensor for adenosine
    Liu, Zhongyuan
    Yuan, Ruo
    Chai, Yaqin
    Zhuo, Ying
    Hong, Chenglin
    Yang, Xia
    Su, Huilan
    Qian, Xiaoqing
    ELECTROCHIMICA ACTA, 2009, 54 (26) : 6207 - 6211
  • [49] A highly sensitive and stable electrochemical nitrate biosensor
    Kalimuthu, Palraj
    Kruse, Tobias
    Bernhardt, Paul V.
    ELECTROCHIMICA ACTA, 2021, 386 (386)
  • [50] Highly sensitive catalytic determination of molybdenum
    Mubarak, Ahmed T.
    Mohamed, Ashraf A.
    Fawy, Khaled F.
    Al-Shihry, Ayed S.
    TALANTA, 2007, 71 (02) : 632 - 638