High-Resolution Magnetic Resonance Imaging Using Compressed Sensing for Intracranial and Extracranial Arteries: Comparison with Conventional Parallel Imaging

被引:29
|
作者
Suh, Chong Hyun [1 ,2 ]
Jung, Seung Chai [1 ,2 ]
Lee, Ho Beom [1 ,2 ]
Cho, Se Jin [1 ,2 ]
机构
[1] Univ Ulsan, Asan Med Ctr, Dept Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
[2] Univ Ulsan, Asan Med Ctr, Res Inst Radiol, Coll Med, 88 Olymp Ro 43 Gil, Seoul 05505, South Korea
关键词
Intracranial artery disease; Image quality; Undersampling; Reconstruction method; Signal-to-noise ratio; Contrast-to-noise ratio; Compressed sensing; DIGITAL-SUBTRACTION-ANGIOGRAPHY; VESSEL WALL; BLACK; MRI; DIAGNOSIS;
D O I
10.3348/kjr.2018.0424
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To compare conventional sensitivity encoding (SENSE) to compressed sensing plus SENSE (CS) for high-resolution magnetic resonance imaging (HR-MRI) of intracranial and extracranial arteries. Materials and Methods: HR-MRI was performed in 14 healthy volunteers. Three-dimensional T1-weighted imaging (T1WI) and proton density-weighted imaging (PD) were acquired using CS or SENSE under the same total acceleration factors (AF(t))-5.5, 6.8, and 9.7 for T1WI and 3.2, 4.0, and 5.8 for PD-to achieve reduced scanning times in comparison with the original imaging sequence (SENSE T1WI, AF(t) 3.5; SENSE PD, AF(t) 2.0) using the 3-tesla system. Two neuroradiologists measured signalto-noise ratio (SNR) and contrast-to-noise ratio (CNR), and used visual scoring systems to assess image quality. Acceptable imaging was defined as a visual score >= 2. Repeated measures analysis of variance and Cochran's Q test were performed. Results: CS yielded better image quality and vessel delineation than SENSE in T1WI with AF(t) of 5.5, 6.8, and 9.7, and in PD with AF(t) of 5.8 (p < 0.05). CS T1WI with AF(t) of 5.5 and CS PD with AF(t) of 3.2 and 4.0 did not differ significantly from original imaging (p > 0.05). SNR and CNR in CS were higher than they were in SENSE, but lower than they were in the original images (p < 0.05). CS yielded higher proportions of acceptable imaging than SENSE (CS T1WI with AF(t) of 6.8 and PD with AF(t) of 5.8; p < 0.0167). Conclusion: CS is superior to SENSE, and may be a reliable acceleration method for vessel HR-MRI using AF(t) of 5.5 for T1WI, and 3.2 and 4.0 for PD.
引用
收藏
页码:487 / 497
页数:11
相关论文
共 50 条
  • [41] Magnetic resonance cholangiopancreatography using optimized integrated combination with parallel imaging and compressed sensing technique
    Nagata, Shoma
    Goshima, Satoshi
    Noda, Yoshifumi
    Kawai, Nobuyuki
    Kajita, Kimihiro
    Kawada, Hiroshi
    Tanahashi, Yukichi
    Matsuo, Masayuki
    ABDOMINAL RADIOLOGY, 2019, 44 (05) : 1766 - 1772
  • [42] Compressed sensing trends in magnetic resonance imaging
    Sandilya, Mrinmoy
    Nirmala, S. R.
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2017, 20 (04): : 1342 - 1352
  • [43] High-Resolution Radar Imaging of Moving Humans Using Doppler Processing and Compressed Sensing
    Ram, Shobha Sundar
    Majumdar, Angshul
    IEEE TRANSACTIONS ON AEROSPACE AND ELECTRONIC SYSTEMS, 2015, 51 (02) : 1279 - 1287
  • [44] High Resolution Magnetic Resonance Imaging (HRMRI) in Intracranial Atherosclerosis
    Turan, Tanya N.
    Brown, Truman R.
    Rumboldt, Zoran
    Adams, Robert J.
    ANNALS OF NEUROLOGY, 2012, 72 : S133 - S134
  • [45] High Resolution Magnetic Resonance Imaging (HRMRI) in Intracranial Atherosclerosis
    Turan, Tanya N.
    Brown, Truman R.
    Rumboldt, Zoran
    Adams, Robert J.
    ANNALS OF NEUROLOGY, 2012, 72 : S7 - S7
  • [46] Comparison of compressed sensing and controlled aliasing in parallel imaging acceleration for 3D magnetic resonance imaging for radiotherapy preparation
    Crop, Frederik
    Guillaud, Ophelie
    Amor, Mariem Ben Haj
    Gaignierre, Alexandre
    Barre, Carole
    Fayard, Cindy
    Vandendorpe, Benjamin
    Lodyga, Kaoutar
    Mouttet-Audouard, Raphaelle
    Mirabel, Xavier
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2022, 23 : 44 - 47
  • [47] High-resolution magnetic resonance imaging of recurrent pneumoparotitis
    Sittel, C
    Jungehülsing, M
    Fischbach, R
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1999, 108 (08): : 816 - 818
  • [48] High-resolution Magnetic Resonance Imaging of Moyamoya Disease
    Yu Le-Bao
    Zhang Qian
    Shi Zhi-Yong
    Wang Ming-Qiu
    Zhang Dong
    中华医学杂志英文版, 2015, 128 (23) : 3231 - 3237
  • [49] High-resolution magnetic resonance spectroscopic imaging in MS
    Bogner, W.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 82 - 82
  • [50] High-resolution Magnetic Resonance Imaging of Moyamoya Disease
    Yu, Le-Bao
    Zhang, Qian
    Shi, Zhi-Yong
    Wang, Ming-Qiu
    Zhang, Dong
    CHINESE MEDICAL JOURNAL, 2015, 128 (23) : 3231 - 3237