A Novel Chitosan Nanoparticle-Schiff Base Modified Carbon Paste Electrode as a Sensor for the Determination of Pb(II) in Waste Water

被引:0
|
作者
Kucukkolbasi, Semahat [1 ]
Erdogan, Zehra Ozden [1 ]
Barek, Jiri [3 ]
Sahin, Mustafa [1 ]
Kocak, Nuriye [2 ]
机构
[1] Selcuk Univ, Dept Chem, Fac Sci, TR-42075 Konya, Turkey
[2] Necmettin Erbakan Univ, Dept Sci Educ, Fac Educ, TR-42090 Konya, Turkey
[3] Charles Univ Prague, Univ Ctr Excellence UNCE Supramol Chem, Dept Analyt Chem, UNESCO Lab Environm Electrochem,Fac Sci, Praguze 12843 2, Czech Republic
来源
关键词
Chitosan nanoparticles; Schiff base; Carbon paste electrode; Lead (II) sensor; Voltammetry; ANODIC-STRIPPING VOLTAMMETRY; LEAD IONS; CADMIUM; MERCURY; COPPER; REMOVAL; SAMPLES;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This paper describes the preparation and electrochemical application of a modified carbon paste electrode with a new kind of chitosan nanoparticle-Schiff base for the determination of Pb(II) ions in waste water using differential pulse anodic stripping voltammetry (DPASV). Firstly a new kind of chitosan nanoparticle-Schiff base (CNSB) was synthesized by chitosan nanoparticle reaction with 2,4-dihydroxybenzaldehyde. CNSB structure was characterized by FT-IR spectroscopy, elemental analysis, particle size and zeta potential. Afterwards, a novel, simple and effective chemically modified carbon paste electrode with CNSB was prepared and characterized using scanning electronic microscopy (SEM-EDX) and anodic stripping voltammetry. The modified electrode showed only one oxidation peak in the anodic scan at -0.35 V (vs. Ag/AgCl) for the oxidation of Pb(II). The electrochemical properties and applications of the modified electrode, including the pH, supporting electrolyte, preconcentration time, reduction potential and time, and percentage of modifier were investigated. The best voltammetric response was observed for a paste composition of 73.7% (w/w) of graphite powder, 5.3% (w/w) of chitosan and 21% (w/w) of paraffin oil, with 0.2 mol L-1 NaAc solution at pH 6.0 as supporting electrolyte, preconcentration time of 600 s, a reduction potential of -0.1 V and reduction time of 10 s. The new electrode displays excellent response to Pb(II) which is linear in the range from 1x10(-6) to 1x10(-4) mol L-1, with a correlation coefficient of 0.998 and a detection limit of 7.24x10(-7) mol L-1.
引用
收藏
页码:2164 / 2181
页数:18
相关论文
共 50 条
  • [21] Development of a carbon nanotubes paste electrode modified with crosslinked chitosan for cadmium(II) and mercury(II) determination
    Janegitz, Bruno C.
    Figueiredo-Filho, Luiz Carlos S.
    Marcolino-Junior, Luiz H.
    Souza, Silveria P. N.
    Pereira-Filho, Edenir R.
    Fatibello-Filho, Orlando
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 660 (01) : 209 - 216
  • [22] Cyclam modified carbon paste electrode as a potentiometric sensor for determination of cobalt(II) ions
    Pouretedal, HR
    Keshavarz, MH
    CHEMICAL RESEARCH IN CHINESE UNIVERSITIES, 2005, 21 (01) : 28 - 31
  • [23] Voltammetric determination of Pb (II) ions by Carbon Paste Electrode modified with Lemon grass powder
    Rajawat, D. S.
    Satsangee, S. P.
    RESEARCH JOURNAL OF CHEMISTRY AND ENVIRONMENT, 2011, 15 (03): : 55 - 59
  • [24] Sensitive voltammetric determination of tryptophan using an acetylene black paste electrode modified with a Schiff's base derivative of chitosan
    Deng, Peihong
    Fei, Junjie
    Feng, Yonglan
    ANALYST, 2011, 136 (24) : 5211 - 5217
  • [25] A glassy carbon electrode modified with bismuth oxide nanoparticles and chitosan as a sensor for Pb(II) and Cd(II)
    Hao, Chen
    Shen, Yuru
    Shen, Junxi
    Xu, Kaiyang
    Wang, Xiaohong
    Zhao, Yutao
    Ge, Cunwang
    MICROCHIMICA ACTA, 2016, 183 (06) : 1823 - 1830
  • [26] A glassy carbon electrode modified with bismuth oxide nanoparticles and chitosan as a sensor for Pb(II) and Cd(II)
    Chen Hao
    Yuru Shen
    Junxi Shen
    Kaiyang Xu
    Xiaohong Wang
    Yutao Zhao
    Cunwang Ge
    Microchimica Acta, 2016, 183 : 1823 - 1830
  • [27] Highly sensitive simultaneous electrochemical determination of trace amounts of Pb(II) and Cd(II) using a carbon paste electrode modified with multi-walled carbon nanotubes and a newly synthesized Schiff base
    Afkhami, Abbas
    Ghaedi, Hamed
    Madrakian, Tayyebeh
    Rezaeivala, Majid
    ELECTROCHIMICA ACTA, 2013, 89 : 377 - 386
  • [28] A sensitive electrochemical sensor for rapid and selective determination of nitrite ion in water samples using modified carbon paste electrode with a newly synthesized cobalt(II)-Schiff base complex and magnetite nanospheres
    Parsaei, Mozhgan
    Asadi, Zahra
    Khodadoust, Saeid
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 1131 - 1138
  • [29] Determination of Pb(II) Based on Dehydroabietylamine Schiff Base-Multi-walled Carbon Nano-tubes Modified Glassy Carbon Electrode
    Pan Tao
    Zhang Xia
    Fu Chang-E
    Yang Xiao-Di
    Xu Li
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (10) : 1501 - 1506
  • [30] Naphthazarin modified carbon paste electrode for determination of copper(II)
    Chaisuksant, Rasamee
    Pattanarat, Lertnapa
    Grudpan, Kate
    MICROCHIMICA ACTA, 2008, 162 (1-2) : 181 - 188