Interference free detection of dihydroxybenzene isomers at pyrogallol film coated electrode: A voltammetric method

被引:20
|
作者
Ganesh, Pattan S. [1 ,2 ]
Swamy, Bahaddurghatta E. Kumara [1 ]
Feyami, Omolola E. [2 ]
Ebenso, Eno E. [2 ]
机构
[1] Kuvempu Univ, Dept PG Studies & Res Ind Chem, Shimoga 577451, Karnataka, India
[2] North West Univ, Fac Nat & Agr Sci, Sch Chem & Phys Sci, Dept Chem, Mafikeng Campus,Private Bag X2046, ZA-2735 Mmabatho, South Africa
关键词
Catechol; Hydroquinone; Pyrogallol film modified carbon paste electrode voltammetry; CARBON-PASTE ELECTRODE; SIMULTANEOUS ELECTROCHEMICAL DETERMINATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; REDUCED GRAPHENE OXIDE; SIMULTANEOUS ELECTROANALYSIS; AMPEROMETRIC DETECTION; CATECHOL DERIVATIVES; BIOLOGICAL SAMPLES; PHENOLIC-COMPOUNDS; MESOPOROUS SILICA;
D O I
10.1016/j.jelechem.2018.02.018
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A carbon paste electrode was modified with pyrogallol red film using a cyclic voltammetric method (CV) and the influence of number of sweep segments on the surface area of was examined. The fabricated film coated electrode exhibited excellent electrocatalytic performance for the electro-oxidation of 1, 2- dihydroxybenzene and 1, 4-dihydroxybenzene. To know the kinetics of electrode process, scan rate study was conducted and it confirms the adsorption controlled electrode kinetics. The redox potentials were dependents on pH and witnessed an identical number transfer of protons and electrons. Also a linearity was observed for the peak current and concentration of both HQ and CC by using differential pulse voltammetric technique (DPV) and gave a detection limit of 0.018 and 0.021 mu M respectively. Furthermore, successful selective separation of phenolic isomers was achieved in a binary mixture. A good analytical results were observed towards the quantification of CC and HQ in a tap water sample.
引用
收藏
页码:193 / 199
页数:7
相关论文
共 50 条
  • [31] Sensitive voltammetric method for the fast analysis of the antioxidant pyrogallol using a boron-doped diamond electrode in biofuels
    Chylkova, Jaromira
    Tomaskova, Marketa
    Janikova, Lenka
    Selesovska, Renata
    Navratil, Tomas
    Chudobova, Petra
    CHEMICAL PAPERS, 2017, 71 (06): : 1047 - 1054
  • [32] Simultaneous detection of dihydroxybenzene isomers in the environment by a free-standing flexible ZnCo2O4 nanoplate arrays/carbon fiber cloth electrode
    Dong, Jiangbo
    Wen, Li
    Liu, Huan
    Yang, Huisi
    Zhao, Jiaying
    Luo, Xiaogang
    Hou, Changjun
    Huo, Danqun
    SCIENCE OF THE TOTAL ENVIRONMENT, 2023, 855
  • [33] Electrochemical reduction and voltammetric determination of metronidazole at a nanomaterial thin film coated glassy carbon electrode
    Lu, SF
    Wu, KB
    Dang, XP
    Hu, SS
    TALANTA, 2004, 63 (03) : 653 - 657
  • [34] Voltammetric Detection of Dopamine in Presence of Ascorbic Acid and Uric Acid at Poly (Xylenol Orange) Film-Coated Graphite Pencil Electrode
    Chandra, Umesh
    Swamy, B. E. Kumara
    Gilbert, Ongera
    Sherigara, B. S.
    INTERNATIONAL JOURNAL OF ELECTROCHEMISTRY, 2011, 2011
  • [35] Fast and Sensitive Voltammetric Method for the Determination of Rifampicin on Renewable Amalgam Film Electrode
    Szlosarczyk, Marek
    Piech, Robert
    Milc, Anna
    Hubicka, Urszula
    SENSORS, 2021, 21 (17)
  • [36] Anodic stripping voltammetric determination of cadmium using a "mercury free" indium film electrode
    Anandhakumar, Sukeri
    Mathiyarasu, Jayaraman
    Phani, Kanala Lakshimi Narasimha
    ANALYST, 2013, 138 (19) : 5674 - 5678
  • [37] Simultaneous determination of dihydroxybenzene isomers using a three-dimensional over-oxidized polypyrrole-reduced graphene oxide composite film electrode prepared by an electrochemical method
    Song, Kai-li
    Li, Rui
    Li, Kun
    Yu, Hao
    NEW JOURNAL OF CHEMISTRY, 2020, 44 (46) : 20294 - 20302
  • [38] Effects of capacitance and resistance of MWNT-film coated electrodes on voltammetric detection of acetaminophen
    Qijin Wan
    Xiuwen Wang
    Fen Yu
    Xiaoxia Wang
    Nianjun Yang
    Journal of Applied Electrochemistry, 2009, 39 : 1145 - 1151
  • [39] Effects of capacitance and resistance of MWNT-film coated electrodes on voltammetric detection of acetaminophen
    Wan, Qijin
    Wang, Xiuwen
    Yu, Fen
    Wang, Xiaoxia
    Yang, Nianjun
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2009, 39 (07) : 1145 - 1151
  • [40] Simple Voltammetric Determination of Iron in Ethanol and Biodiesel Using a Bismuth Film Coated Glassy Carbon Electrode
    Almeida, Joseany M. S.
    Ribeiro, Ana Beatriz P.
    Toloza, Carlos A. T.
    Alves, Ismael C. B.
    Santos, Jose Ribamar N.
    De Azevedo, Lorena C. M.
    Aucelio, Ricardo Q.
    Marques, Aldalea L. B.
    ANALYTICAL LETTERS, 2022, 55 (15) : 2325 - 2346