Control charts to evaluate long-term performance in proficiency tests

被引:8
|
作者
Sorbo, Angela [1 ]
Colabucci, Andrea [1 ]
Ciaralli, Laura [1 ]
机构
[1] Ist Super Sanita, Dept Food Safety & Vet Publ Hlth, European Union Reference Lab Chem Elements Food A, I-00161 Rome, Italy
关键词
European Union Reference Laboratory; Chemical elements; Proficiency test; Shewhart control charts; Cusum control charts; Long-term performance;
D O I
10.1007/s00769-013-0956-0
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
As proficiency tests (PTs) provider, the European Union Reference Laboratory for Chemical Elements in Food of Animal Origin (EURL-CEFAO) yearly organizes exercises on the determination of chemical elements within the area of its mandate. The scheme is addressed to the National Reference Laboratories (NRLs) of the European Union Member States. Each PT is planned giving priority to the matrices and elements for which maximum levels are set in Commission Regulation No. 1881/2006 and following amendments as well as to those mainly considered in National Residues Control Plans. Samples to be distributed are prepared in the Laboratory's facilities using materials purchased on the market and often adjusting the concentration levels of the analytes around their maximum levels. In the 2006-2011 period, PTs were planned as a long-term programme pursuing the general objective of providing the NRLs with a scheme that can give them the opportunity to check and improve the performance of their analytical methods and to verify the effectiveness of any corrective actions through the repetition of the same matrix. Control charts give participants the possibility of a long-term follow-up of their performance promoting the improvement of Quality Control. To this aim, Shewhart and Cusum control charts for z-scores are prepared according to ISO 13528:2005 and updated after each PT for each laboratory. z-scores are assigned using values of sigma (pEURL-CEFAO) that correspond to the level of performance appropriate to the demand. Cusum charts are also evaluated by EURL-CEFAO in order to identify problems that may cause a bias in the measurement method.
引用
收藏
页码:291 / 298
页数:8
相关论文
共 50 条
  • [31] LONG-TERM CLIMATIC TESTS OF COMPONENTS FOR ELECTRONICS
    Tucan, Marek
    Zak, Pavel
    Urbanek, Jan
    ELECTRONIC DEVICES AND SYSTEMS: IMAPS CS INTERNATIONAL CONFERENCE 2011, 2011, : 91 - 94
  • [32] DETERMINING OF EXTENT OF LONG-TERM RELIABILITY TESTS
    TOMASEK, KF
    MICROELECTRONICS AND RELIABILITY, 1971, 10 (04): : 285 - &
  • [33] Long-term field tests of vacuum glazing
    Lenzen, M
    Collins, RE
    SOLAR ENERGY, 1997, 61 (01) : 11 - 15
  • [34] Long-term corrosion tests with Hanford glasses
    Ebert, WL
    Lewis, MA
    Dietz, NL
    ENVIRONMENTAL ISSUES AND WASTE MANAGEMENT TECHNOLOGIES IN THE CERAMIC AND NUCLEAR INDUSTRIES VII, 2002, 132 : 279 - 285
  • [35] LONG-TERM TESTS OF LIMITED STREAMER TUBES
    LAU, K
    PARKS, D
    PYRLIK, J
    WEINSTEIN, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 320 (1-2): : 243 - 248
  • [36] Long-term tests of compact excimer lasers
    Goertler, Andreas
    Matern, Ansgar
    Strowitzki, Claus
    XVI International Symposium on Gas Flow, Chemical Lasers, and High-Power Lasers, Pts 1 and 2, 2007, 6346 : P3460 - P3460
  • [37] Test rigs for long-term tension tests
    Scott, RH
    Beeby, AW
    STRAIN, 2005, 41 (04) : 151 - 155
  • [38] TESTS OF LONG-TERM RESIDUES OF PHOSPHORUS FERTILIZER
    SPARROW, PE
    RUSSELL, RD
    JOURNAL OF THE SCIENCE OF FOOD AND AGRICULTURE, 1977, 28 (08) : 687 - 693
  • [39] APPARATUS FOR LONG-TERM CYCLIC STRENGTH TESTS
    MEDEKSHA, GG
    ZHITKYAVICHENE, VP
    INDUSTRIAL LABORATORY, 1978, 44 (02): : 279 - 281
  • [40] LONG-TERM AND SHORT-TERM TESTS OF CARCINOGENICITY OF CHEMICALS
    SULA, J
    CHEMICKE LISTY, 1984, 78 (10): : 1050 - 1064