Performance of the GeneXpert CT/NG Assay Compared to That of the Aptima AC2 Assay for Detection of Rectal Chlamydia trachomatis and Neisseria gonorrhoeae by Use of Residual Aptima Samples

被引:38
|
作者
Goldenberg, S. D. [1 ,2 ]
Finn, J.
Sedudzi, E. [3 ]
White, J. A. [4 ]
Tong, C. Y. W. [1 ,2 ]
机构
[1] Guys & St Thomas NHS Fdn Trust, Ctr Clin Infect & Diagnost Res, London, England
[2] Kings Coll London, London WC2R 2LS, England
[3] GSTS Pathol, London, England
[4] Guys & St Thomas NHS Fdn Trust, Dept Genitourinary Med, London, England
关键词
DIAGNOSIS; SWABS; MEN; SEX;
D O I
10.1128/JCM.01930-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
There are currently no commercially available molecular assays for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in rectal swabs with regulatory approval. We compared the Cepheid GeneXpert CT/NG assay with the GenProbe Aptima Combo2 assay, using 409 rectal swabs. Using Aptima as the gold standard, the sensitivity, specificity, and positive and negative predictive values of GeneXpert for the detection of C. trachomatis and N. gonorrhoeae were 86%, 99.2%, 92.5%, and 98.4% and 91.1%, 100%, 100%, and 98.6%, respectively. Despite significant dilution of samples prior to GeneXpert testing, the assay performed well with excellent specificity.
引用
收藏
页码:3867 / 3869
页数:3
相关论文
共 50 条
  • [1] Performance of the cobas CT/NG Test Compared to the Aptima AC2 and Viper CTQ/GCQ Assays for Detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Van Der Pol, Barbara
    Liesenfeld, Oliver
    Williams, James A.
    Taylor, Stephanie N.
    Lillis, Rebecca A.
    Body, Barbara A.
    Nye, Mindy
    Eisenhut, Carol
    Hook, Edward W., III
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (07) : 2244 - 2249
  • [2] Evaluation of pooled ocular and vaginal swabs by the Cepheid GeneXpert CT/NG assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae compared to the GenProbe Aptima Combo 2 Assay
    Dize, L.
    West, S. K.
    Mkocha, H.
    Quinn, T. C.
    Gaydos, C. A.
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2015, 81 (02) : 102 - 104
  • [3] Comparison of the Cepheid GeneXpert CT/NG assay to the Hologic Aptima Combo2 assay for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae in self-collected rectal swabs
    Dize, Laura
    Silver, Barbara
    Gaydos, Charlotte
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2018, 90 (02) : 83 - 84
  • [4] Evaluation of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae.
    Boyadzhyan, B
    Yashina, T
    Yatabe, JAH
    Patnaik, M
    CLINICAL CHEMISTRY, 2001, 47 (11) : 2082 - 2082
  • [5] Confirmation of Aptima-Positive Chlamydia trachomatis and/or Neisseria gonorrhoeae Samples Using Extracted Nucleic Acid in the Xpert CT/NG Assay
    Rahman, A.
    Cuevas, D.
    Ha, M.
    Luong, T.
    Rector, A.
    Garcia, A.
    Ton, T.
    Dunn, J.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2022, 24 (10): : S51 - S51
  • [6] Comparison of the gen-probe APTIMA Combo 2 assay to the AMPLICOR CT/NG assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in urine samples from Australian men and women
    Lowe, Peter
    O'Loughlin, Peter
    Evans, Kathryn
    White, Michael
    Bartley, Paul B.
    Vohra, Renu
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (07) : 2619 - 2621
  • [7] Performance of the APTIMA Combo 2 assay for detection of Chlamydia trachomatis and Neisseria gonorrhoeae in female urine and endocervical swab specimens
    Gaydos, CA
    Quinn, TC
    Willis, D
    Weissfeld, A
    Hook, EW
    Martin, DH
    Ferrero, DV
    Schachter, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (01) : 304 - 309
  • [8] Detection of Chlamydia trachomatis and Neisseria gonorrhoeae with the cobas CT/NG v2.0 test: performance compared with the BD ProbeTec CT Qx and GC Qx amplified DNA and Aptima AC2 assays
    Nye, Melinda B.
    Osiecki, John
    Lewinski, Michael
    Liesenfeld, Oliver
    Young, Stephen
    Taylor, Stephanie N.
    Lillis, Rebecca A.
    Body, Barbara A.
    Eisenhut, Carol
    Hook, Edward W., III
    Van Der Pol, Barbara
    SEXUALLY TRANSMITTED INFECTIONS, 2019, 95 (02) : 87 - 93
  • [9] A VALIDATION STUDY OF THE GEN-PROBE APTIMA COMBO2 (AC2) ASSAY FOR DETECTING CHLAMYDIA TRACHOMATIS AND NEISSERIA GONORRHOEAE IN DRY SWABS
    Cosentino, L.
    Schwebke, J. R.
    Hobbs, M. M.
    Hillier, S. L.
    SEXUALLY TRANSMITTED INFECTIONS, 2011, 87 : A278 - A278
  • [10] Comparison of the APTIMA CT and GC assays with the APTIMA combo 2 assay, the Abbott LCx assay, and direct fluorescent-antibody and culture assays for detection of Chlamydia trachomatis and Neisseria gonorrhoeae
    Boyadzhyan, B
    Yashina, T
    Yatabe, JH
    Patnaik, M
    Hill, CS
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (07) : 3089 - 3093