摘要
The behavior of steel columns subjected to fire depends on their interaction with the surrounding building structure. To improve knowledge of the phenomenon a great many fire resistance tests have been carried out on steel columns with restrained thermal elongation. A new experimental system was designed and constructed to carry out the tests. The columns tested had slenderness of 50.6 and 63.3, an initial applied load of 30% and 70% of the column's design value of the buckling load at room temperature and an axial stiffness of the surrounding structure of 13,45 and 63.3 kN/mm. Also tested were columns with initial applied loading eccentricity equal to the width of the cross-section in the direction of the weak inertia axis or both principal inertia axes. The results showed that increasing the stiffness of the surrounding structure may not lead to a reduction of the column's critical temperature. This is because, associated with an increase of the axial stiffness is an increase of the rotational stiffness, which has an opposite effect to the first one. It was also noted that the higher initial applied load levels resulted in shorter critical temperatures of the columns. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1 / 11
页数:11
相关论文
共 50 条
  • [31] Comparing fire behaviour of restrained hollow stainless steel with carbon steel columns
    Rodrigues, Joao Paulo C.
    Laim, Luis
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 153 : 449 - 458
  • [32] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (03): : 82 - 94
  • [33] FIRE RESISTANCE OF PROTECTED STEEL COLUMNS
    STETINA, HJ
    LIE, TT
    STANZAK, WW
    ENGINEERING JOURNAL-AMERICAN INSTITUTE OF STEEL CONSTRUCTION INC, 1973, 10 (04): : 134 - 136
  • [34] FIRE RESISTANCE OF UNPROTECTED STEEL COLUMNS
    KAMATH, CM
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1974, 100 (NST4): : 821 - 821
  • [35] FIRE RESISTANCE OF COLUMNS IN STEEL FRAMES
    FRANSSEN, JM
    DOTREPPE, JC
    FIRE SAFETY JOURNAL, 1992, 19 (2-3) : 159 - 175
  • [36] FIRE RESISTANCE OF SOLID STEEL COLUMNS
    KLINGSCH, W
    FIRE SAFETY JOURNAL, 1982, 4 (04) : 237 - 241
  • [37] Experimental study on fire resistance of axially restrained high strength Q460 steel columns
    Wang, Weiyong
    Ge, Yong
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2015, 36 (08): : 116 - 122
  • [38] Fire resistance of restrained circular concrete-filled double-skin steel tubular columns
    Zheng, Yong-Qian
    Liang, Wang-Geng
    Zhang, Xue-Li
    MAGAZINE OF CONCRETE RESEARCH, 2022, 74 (11) : 557 - 571
  • [39] FIRE RESISTANCE OF FIRE-RESISTANT STEEL COLUMNS
    SAKUMOTO, Y
    YAMAGUCHI, T
    OKADA, T
    YOSHIDA, M
    TASAKA, S
    SAITO, H
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (04): : 1103 - 1121
  • [40] Thermal restraint and fire resistance of columns
    Neves, IC
    Valente, JC
    Rodrigues, JPC
    FIRE SAFETY JOURNAL, 2002, 37 (08) : 753 - 771