A Laboratory Insole for Analysis of Sensor Placement to Determine Ground Reaction Force and Ankle Moment in Patients with Stroke

被引:0
|
作者
Howell, Adam M. [1 ]
Kobayashi, Toshiki
Chou, Teri Rosenbaum
Daly, Wayne
Orendurff, Michael
Bamberg, Stacy J. Morris [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84121 USA
关键词
SYSTEM; GAIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An insole system was constructed with 32 sensors inside a size 10 men's shoe. This system allows evaluation of the contributions of individual sensors spread throughout the surface area of the insole. The kinetic variables of interest in this initial study are ground reaction force and anterior-posterior ankle moment. Use of all 32 sensors are able to replicate the shape of the ground reaction force and ankle moment in a stroke patient who has regained a more normal gait, but less so in a stroke patient with impaired gait. Subsets of sensors can now be evaluated in order to ultimately identify an optimum set of sensors for determining kinetic variables necessary to classify presence or absence of a particular gait abnormality or other pathology.
引用
收藏
页码:6394 / 6397
页数:4
相关论文
共 28 条
  • [21] Does Vertical Ground Reaction Force of the Hip, Knee, and Ankle Joints Change in Patients with Adolescent Idiopathic Scoliosis after Spinal Fusion?
    Yusof, Mohd Imran
    Shaharudin, Shazlin
    Sivalingarajah, Prema
    ASIAN SPINE JOURNAL, 2018, 12 (02) : 349 - 355
  • [22] Associations among knee adduction moment, frontal plane ground reaction force, and lever arm during walking in patients with knee osteoarthritis
    Hunt, Michael A.
    Birmingham, Trevor B.
    Giffin, J. Robert
    Jenkyn, Thomas R.
    JOURNAL OF BIOMECHANICS, 2006, 39 (12) : 2213 - 2220
  • [23] Development of a Three-Axis Monolithic Flexure-Based Ground Reaction Force Sensor for Various Gait Analysis
    Jang, Seung-Yeon
    Youn, Jung-Hwan
    Lim, Su Hyun
    Kim, Seong Su
    Kim, Uikyum
    Kyung, Ki-Uk
    IEEE ROBOTICS AND AUTOMATION LETTERS, 2022, 7 (02): : 4118 - 4125
  • [24] VERTICAL GROUND REACTION FORCE FEEDBACK TO ENHANCE STROKE PATIENTS SYMMETRICAL BODY-WEIGHT DISTRIBUTION WHILE RISING SITTING DOWN
    ENGARDT, M
    RIBBE, T
    OLSSON, E
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1993, 25 (01): : 41 - 48
  • [25] Importance of femoral tunnel placement in double-bundle posterior cruciate ligament reconstruction - Biomechanical analysis using a robotic/universal force-moment sensor testing system
    Petersen, W
    Lenschow, S
    Weimann, A
    Strobel, MJ
    Raschke, MJ
    Zantop, T
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (03): : 456 - 463
  • [26] A Preliminary Study on Kinetic Analysis of Ground Reaction Force and Impulse During Gait in Patients With Total Hip Replacement and Implication for Rehabilitation
    Zhao, Yuting
    Raza, Wasim
    Arnold, Graham
    Li, Penghai
    Wang, Weijie
    ORTHOPAEDIC SURGERY, 2024, 16 (12) : 3162 - 3178
  • [27] One-Step Gait Pattern Analysis of Hip Osteoarthritis Patients Based on Dynamic Time Warping through Ground Reaction Force
    Ahn, Sohyun
    Choi, Wiha
    Jeong, Hieyong
    Oh, Sehoon
    Jung, Tae-Du
    APPLIED SCIENCES-BASEL, 2023, 13 (08):
  • [28] Patients with Patellofemoral Pain Exhibiting Decrease Vertical Ground Reaction Force Compared to Healthy Individuals during Weight Bearing Tasks: A Systematic Reviews and Meta-Analysis
    Yalfani, Ali
    Ahmadi, Mohamadreza
    IRANIAN JOURNAL OF PUBLIC HEALTH, 2023, 52 (02) : 254 - 264