A Laboratory Insole for Analysis of Sensor Placement to Determine Ground Reaction Force and Ankle Moment in Patients with Stroke

被引:0
|
作者
Howell, Adam M. [1 ]
Kobayashi, Toshiki
Chou, Teri Rosenbaum
Daly, Wayne
Orendurff, Michael
Bamberg, Stacy J. Morris [1 ]
机构
[1] Univ Utah, Dept Mech Engn, Salt Lake City, UT 84121 USA
关键词
SYSTEM; GAIT;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An insole system was constructed with 32 sensors inside a size 10 men's shoe. This system allows evaluation of the contributions of individual sensors spread throughout the surface area of the insole. The kinetic variables of interest in this initial study are ground reaction force and anterior-posterior ankle moment. Use of all 32 sensors are able to replicate the shape of the ground reaction force and ankle moment in a stroke patient who has regained a more normal gait, but less so in a stroke patient with impaired gait. Subsets of sensors can now be evaluated in order to ultimately identify an optimum set of sensors for determining kinetic variables necessary to classify presence or absence of a particular gait abnormality or other pathology.
引用
收藏
页码:6394 / 6397
页数:4
相关论文
共 28 条
  • [1] Estimation of ankle moment using ambulatory measurement of ground reaction force and movement of foot and ankle
    Schepers, H. Martin
    Veltink, Peter H.
    2006 1ST IEEE RAS-EMBS INTERNATIONAL CONFERENCE ON BIOMEDICAL ROBOTICS AND BIOMECHATRONICS, VOLS 1-3, 2006, : 739 - +
  • [2] Prediction model and analysis of foot-ground reaction force based on pressure insole
    Wang H.
    Lang R.
    Wang F.
    Xu F.
    Shen J.
    Fangzhi Xuebao/Journal of Textile Research, 2019, 40 (11): : 175 - 181
  • [3] Estimation of ground reaction force and zero moment point on a powered ankle-foot prosthesis
    Martinez-Villalpando, Emesto C.
    Herr, Hugh
    Farrell, Mafthew
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 4687 - 4692
  • [4] A Systematic Approach to the Design and Characterization of a Smart Insole for Detecting Vertical Ground Reaction Force (vGRF) in Gait Analysis
    Tahir, Anas M.
    Chowdhury, Muhammad E. H.
    Khandakar, Amith
    Al-Hamouz, Sara
    Abdalla, Merna
    Awadallah, Sara
    Reaz, Mamun Bin Ibne
    Al-Emadi, Nasser
    SENSORS, 2020, 20 (04)
  • [5] Ground reaction force analysed with correlation coefficient matrix in group of stroke patients
    Szczerbik, Ewa
    Krawczyk, Maciej
    Syczewska, Malgorzata
    ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (02) : 3 - 9
  • [6] Estimating GRF(Ground Reaction Force) and Calibrating CoP(Center of Pressure) of an Insole Measured by an Low-Cost Sensor with Neural Network
    Choi, Ho Seon
    Shim, Myounghoon
    Lee, Chang Hee
    Baek, Yoon Su
    PROCEEDINGS 2018 IEEE 18TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2018, : 185 - 188
  • [7] GAIT ANALYSIS OF HEMIPLEGIC PATIENTS BY MEASUREMENT OF GROUND REACTION FORCE
    MORITA, S
    YAMAMOTO, H
    FURUYA, K
    SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE, 1995, 27 (01): : 37 - 42
  • [8] A mathematical model for the validation of the ground reaction force sensor in human gait analysis
    Garza-Ulloa, Jorge
    Yu, Huiying
    Sarkodie-Gyan, Thompson
    MEASUREMENT, 2012, 45 (04) : 755 - 762
  • [9] Leaf-Inspired FSR Array and Insole-Type Sensor Module for Mobile Three-Dimensional Ground Reaction Force Estimation
    Kim, Taeyeon
    Song, Eunseok
    Ant, Seongbin
    Choi, Hyunjin
    Kong, Kyoungchul
    2024 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA 2024), 2024, : 17459 - 17464
  • [10] Changes in Muscle Activation and Ground Reaction Force of the Lower Limbs According to Foot Placement During Sit-to-Stand Training in Stroke Patients
    Noh, Hyeon-Je
    Kim, Chang-Yong
    Kim, Hyeong-Dong
    Kim, Suhng-Wook
    AMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, 2020, 99 (04) : 330 - 337