Non-invasive assessment of cardiac output at rest and during exercise by finger plethysmography

被引:9
|
作者
Critoph, Christopher H. [1 ]
Patel, Vimal [1 ]
Mist, Bryan [1 ]
Thomas, Martin D. [1 ]
Elliott, Perry M. [1 ]
机构
[1] UCL, Inst Cardiovasc Sci, Heart Hosp, London W1G 8PH, England
关键词
acetylene uptake; cycle ergometer; haemodynamics; Modelflow; pulse waveform analysis; BRACHIAL-ARTERY PRESSURE; MAXIMAL AEROBIC EXERCISE; AORTIC INPUT IMPEDANCE; DIRECT FICK METHOD; PHASE-CONTRAST MR; HEART-FAILURE; STROKE VOLUME; DOPPLER-ECHOCARDIOGRAPHY; OXYGEN-CONSUMPTION; REBREATHING METHOD;
D O I
10.1111/cpf.12032
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: We sought to determine the accuracy of finger plethysmography using pulse waveform analysis with brachial calibration for measurement of cardiac output during submaximal exercise by comparing it against an acetylene (C2H2) uptake technique. Methods: The study included 24 healthy volunteers (12 males, age 35 +/- 8 years). Testing was performed on an upright cycle ergometer using an incremental protocol. Cardiac output measurements were performed at rest and during sub-maximal exercise using a single breath C2H2 uptake technique and continuously using finger plethysmography with brachial calibration. Results: Valid results at rest and during sub-maximal exercise were achieved in 20 of 24 participants. Cardiac output at rest was 5.3 +/- 1.1 and 5.2 +/- 1.2 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.712. Mean difference between techniques was -0.1 +/- 0.5 l min(-1). Cardiac output during submaximal exercise was 10.2 +/- 2.3 and 10.3 +/- 2.1 l min(-1) for finger plethysmography and C2H2, respectively, P = 0.898. Mean difference between techniques was 0.1 +/- 1.5 l min(-1). The overall correlation between finger plethysmography and C2H2 data obtained during rest and exercise was r(2) = 0.872, P<0.0001. Mean rise in cardiac output during exercise was 4.9 +/- 1.5 (finger plethysmography) and 5.1 +/- 1.5 l min(-1) (C2H2), P = 0.64. Conclusion: Finger plethysmography determined cardiac output values both at rest and during sub-maximal exercise are comparable with those obtained using a single breath C2H2 uptake technique.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [21] Non-invasive Assessment of Blood Glucose by Photo Plethysmography
    Jindal, G. D.
    Ananthakrishnan, T. S.
    Jain, Rajesh Kumar
    Sinha, Vineet
    Kini, A. R.
    Deshpande, Alakak
    IETE JOURNAL OF RESEARCH, 2008, 54 (03) : 217 - 222
  • [22] The predictive value of non-invasive cardiac output at rest in discharged heart failure patients
    Feola, Mauro
    Testa, Marzia
    Leto, Laura
    Rosso, Gian Luca
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 188 : 50 - 51
  • [23] Optimization of the atrioventricular delay during cardiac resynchronization therapy using a device for non-invasive measurement of cardiac index at rest and during exercise
    Prochnau, Dirk
    Forberg, Thomas
    Kuehnert, Helmut
    Heinke, Matthias
    Figulla, Hans R.
    Surber, Ralf
    EUROPACE, 2012, 14 (02): : 249 - 253
  • [24] A NON-INVASIVE ASSESSMENT OF CARDIAC-OUTPUT BY A SINGLE BREATH TECHNIQUE
    ELKAYAM, U
    WILSON, A
    MORRISON, J
    DAVIS, J
    KLOSTERMAN, P
    SALNESS, K
    LOUVIER, J
    HENRY, WL
    CIRCULATION, 1981, 64 (04) : 300 - 300
  • [25] Non-invasive cardiac output assessment in critically ill paediatric patients
    Wongsirimetheekul, Theeranan
    Khositseth, Anant
    Lertbunrian, Rojjanee
    ACTA CARDIOLOGICA, 2014, 69 (02) : 167 - 173
  • [26] Non-invasive cardiac output trending during exercise recovery on a bathroom-scale-based ballistocardiograph
    Inan, O. T.
    Etemadi, M.
    Paloma, A.
    Giovangrandi, L.
    Kovacs, G. T. A.
    PHYSIOLOGICAL MEASUREMENT, 2009, 30 (03) : 261 - 274
  • [27] A Non-Invasive Assessment of Cardiac Output in Pediatric Heart Transplant Patients
    Likes, M. L.
    Alejos, J. C.
    JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2010, 29 (02): : S172 - S172
  • [28] Measurement of non-invasive cardiac output during cycling exercise in ischemic stroke inpatients: A pilot study
    Yang, Ying
    Qian, Qiu-Yang
    Yang, Xiao-Yan
    Li, De-Sheng
    Chen, De-Sheng
    Shen, Mei
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (01) : 215 - 228
  • [29] Non-invasive estimate of cardiac output during exercise based on impedance cardiography and oxygen uptake in the elderly
    Rodrigues, Mauricio Nunes
    Vanfraechem, Jacques Henri-Paul
    Farinatti, Paulo de Tarso Veras
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (01) : 79 - 84
  • [30] CORRELATION BETWEEN INVASIVE AND NON-INVASIVE CARDIAC OUTPUT ASSESSMENT IN HEART TRANSPLANT PATIENTS
    Al-Subu, Awni
    Cheifetz, Ira
    Lodge, Andrew
    Hornik, Christoph
    Ofori-Amanfo, George
    CRITICAL CARE MEDICINE, 2014, 42 (12)