Risk factors for insufficient fixation of microkeratome during laser in situ keratomileusis

被引:0
|
作者
Asano-Kato, N
Toda, I
Hori-Komai, Y
Takano, Y
Tsubota, K
机构
[1] Minamiaoyama Eye Clin, Minato Ku, Tokyo 1070062, Japan
[2] Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the potential risk factors leading to insufficient fixation of a microkeratome during laser in situ keratomileusis (LASIK), especially in Asian eyes. METHODS: We performed a retrospective analysis of 1809 eyes of 972 patients that underwent LASIK. Profiles of patients (age, sex, past medical history, width of palpebral fissure, corneal power, and postoperative clinical course) whose operations were discontinued due to insufficient fixation were compared to all LASIK patients. RESULTS: Insufficient fixation was observed in 18 eyes of 16 patients. Those patients were significantly younger (26.1 +/- 5.5 yr) compared to all patients (32.3 +/- 8.6 yr). Mean keratometric power was 42.40 +/- 1.37 D in patients with insufficient fixation and 43.60 +/- 1.40 D in all patients (P<.001). Maximum width of palpebral fissure with eyes wide open was 0.96 +/- 0.20 mm in patients with insufficient fixation, and 1.10 +/- 0.19 mm in all patients (P=.0015). These patients subsequently underwent LASIK utilizing combinations of cooling, frequent corticosteroid instillation for several hours, and lateral canthotomy. CONCLUSION: Narrow palpebral fissures commonly found in Asian populations might be a risk factor for insufficient fixation of a microkeratome in LASIK, especially in young patients with flat corneas.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 50 条
  • [31] Intraoperative microkeratome complications in 47,094 laser in situ keratomileusis surgeries
    Nakano, K
    Nakano, E
    Oliveira, M
    Portellinha, W
    Alvarenga, L
    JOURNAL OF REFRACTIVE SURGERY, 2004, 20 (05) : S723 - S726
  • [32] Measurement of corneal flop thickness in Laser in situ Keratomileusis using the Hansatome microkeratome
    Lancione, RR
    Huang, D
    Rymers, A
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S897 - S897
  • [33] Risk factors for intraoperative epithelial defect in laser in situ keratomileusis
    Sharma, N
    Pangtey, MS
    Vajpayee, RB
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (02) : 393 - 394
  • [34] Comparison of laser in situ keratomileusis flaps created by 3 femtosecond lasers and a microkeratome
    Ahn, Hyunseok
    Kim, Jin-Kook
    Kim, Chang Kook
    Han, Gyu Heon
    Seo, Kyoung Yul
    Kim, Eung Kweon
    Kim, Tae-im
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (02): : 349 - 357
  • [35] Reproducibility of corneal flap thickness in laser in situ keratomileusis using the Hansatome microkeratome
    Yildirim, R
    Aras, C
    Ozdamar, A
    Bahcecioglu, H
    Ozkan, S
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (12): : 1729 - 1732
  • [36] Corneal flap thickness in laser in situ keratomileusis using an SCMD manual microkeratome
    Yi, WM
    Joo, CK
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08): : 1087 - 1092
  • [37] Femtosecond-Assisted Laser in situ Keratomileusis with de novo Flap Creation Following Previous Microkeratome Laser in situ Keratomileusis [Response to Letter]
    Rush, Sloan W.
    Rush, Ryan B.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 2945 - 2946
  • [38] Flap Thickness and the Risk of Complications in Mechanical Microkeratome and Femtosecond Laser In Situ Keratomileusis: A Literature Review and Statistical Analysis
    Kanclerz, Piotr
    Khoramnia, Ramin
    DIAGNOSTICS, 2021, 11 (09)
  • [39] Blade source effect on laser in situ keratomileusis flap thickness with the Amadeus I microkeratome
    Ruth, Adrienne L.
    Lynn, Michael J.
    Randleman, J. Bradley
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03): : 407 - 410
  • [40] Flap complications in our learning curve of laser in situ keratomileusis using the Hansatome microkeratome
    Yildirim, R
    Devranoglu, K
    Ozdamar, A
    Aras, C
    Ozkiris, A
    Ozkan, S
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2001, 11 (04) : 328 - 332