Risk factors for insufficient fixation of microkeratome during laser in situ keratomileusis

被引:0
|
作者
Asano-Kato, N
Toda, I
Hori-Komai, Y
Takano, Y
Tsubota, K
机构
[1] Minamiaoyama Eye Clin, Minato Ku, Tokyo 1070062, Japan
[2] Tokyo Dent Coll, Dept Ophthalmol, Chiba, Japan
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To investigate the potential risk factors leading to insufficient fixation of a microkeratome during laser in situ keratomileusis (LASIK), especially in Asian eyes. METHODS: We performed a retrospective analysis of 1809 eyes of 972 patients that underwent LASIK. Profiles of patients (age, sex, past medical history, width of palpebral fissure, corneal power, and postoperative clinical course) whose operations were discontinued due to insufficient fixation were compared to all LASIK patients. RESULTS: Insufficient fixation was observed in 18 eyes of 16 patients. Those patients were significantly younger (26.1 +/- 5.5 yr) compared to all patients (32.3 +/- 8.6 yr). Mean keratometric power was 42.40 +/- 1.37 D in patients with insufficient fixation and 43.60 +/- 1.40 D in all patients (P<.001). Maximum width of palpebral fissure with eyes wide open was 0.96 +/- 0.20 mm in patients with insufficient fixation, and 1.10 +/- 0.19 mm in all patients (P=.0015). These patients subsequently underwent LASIK utilizing combinations of cooling, frequent corticosteroid instillation for several hours, and lateral canthotomy. CONCLUSION: Narrow palpebral fissures commonly found in Asian populations might be a risk factor for insufficient fixation of a microkeratome in LASIK, especially in young patients with flat corneas.
引用
收藏
页码:47 / 50
页数:4
相关论文
共 50 条
  • [1] Anatomic factors affecting microkeratome placement in laser in situ keratomileusis
    Booranapong, W
    Malathum, P
    Slade, SG
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (09): : 1319 - 1325
  • [2] Microkeratome complications of laser in situ keratomileusis
    Tham, VMB
    Maloney, RK
    OPHTHALMOLOGY, 2000, 107 (05) : 920 - 924
  • [3] Laser in situ keratomileusis with microkeratome or femtosecond laser
    Kohnen, T.
    Steinwender, G.
    OPHTHALMOLOGE, 2017, 114 (07): : 661 - 665
  • [4] Factors affecting laser in situ keratomileusis flap thickness: Comparison of 2 microkeratome heads
    Mimouni, Michael
    Nemet, Arie Y.
    Levartovsky, Shmuel
    Sela, Tzahi
    Munzer, Gur
    Kaiserman, Igor
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (02): : 348 - 353
  • [5] Femtosecond Laser vs Mechanical Microkeratome for Hyperopic Laser In Situ Keratomileusis
    Gil-Cazorla, Raquel
    Teus, Miguel A.
    de Benito-Llopis, Laura
    Mikropoulos, Dimitrios G.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (01) : 16 - 21
  • [6] Risk factors for epithelial defect formation during laser in situ keratomileusis
    Randleman, J. Bradley
    Lynn, Michael J.
    Banning, Christopher S.
    Stulting, R. Doyle
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (10): : 1738 - 1743
  • [7] Comparison of the IntraLase femtosecond laser and mechanical microkeratome for laser in situ keratomileusis
    Lim, Taehyung
    Yang, Sungjae
    Kim, Myoung Joon
    Tchah, Hungwon
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) : 833 - 839
  • [8] Corneal flap assessment with Rondo microkeratome in laser in situ keratomileusis
    Paschalis, Eleftherios I.
    Aristeidou, Antonis P.
    Foudoulakis, Nikitas C.
    Razis, Lambros A.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (02) : 289 - 295
  • [9] Experimental observation of intraocular pressure changes during microkeratome suctioning in laser in situ keratomileusis
    Bissen-Miyajima, H
    Suzuki, S
    Ohashi, Y
    Minami, K
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (03): : 590 - 594
  • [10] Corneal flap assessment with Rondo microkeratome in laser in situ keratomileusis
    Eleftherios I. Paschalis
    Antonis P. Aristeidou
    Nikitas C. Foudoulakis
    Lambros A. Razis
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2011, 249 : 289 - 295