Effects of Screw Configuration on the Preload Force of Implant-Abutment Screws

被引:19
|
作者
Zipprich, Holger [1 ]
Rathe, Florian [2 ]
Pinz, Soeren [3 ]
Schlotmann, Luca [3 ]
Lauer, Hans-Christoph [3 ]
Ratka, Christoph [3 ]
机构
[1] Goethe Univ Frankfurt, Dept Prosthodont, Mat Sci Unit, Frankfurt, Germany
[2] DANUBE Private Univ, Dept Prosthodont, Krems An Der Donau, Austria
[3] Goethe Univ Frankfurt, Dept Prosthodont, Theodor Stern Kai 7,House 29, DE-60596 Frankfurt, Germany
关键词
abutment; abutment screw; abutment screw configuration; dental implant; preload force; thread pitch; FINITE-ELEMENT-ANALYSIS; BONE;
D O I
10.11607/jomi.5837
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to investigate the effects of tightening torque, screw head angle, and thread number on the preload force of abutment screws. Materials and Methods: The test specimens consisted of three self-manufactured components (ie, a thread sleeve serving as an implant analog, an abutment analog, and an abutment screw). The abutment screws were fabricated with metric M1.6 external threads. The thread number varied between one and seven threads. The screw head angles were produced in eight varying angles (30 to 180 degrees). A sensor unit simultaneously measured the preload force of the screw and the torsion moment inside the screw shank. The tightening of the screw with the torque wrench was performed in five steps (15 to 35 Ncm). The torque wrench was calibrated before each step. Results: Only the tightening torque and screw head angle affected the resulting preload force of the implant-abutment connection. The thread number had no effect. There was an approximately linear correlation between tightening torque and preload force. Conclusion: The tightening torque and screw head angle were the only study parameters that affected the resulting preload force of the abutment screw. The results obtained from this experiment are valid only for a single torque condition. Further investigations are needed that analyze other parameters that affect preload force. Once these parameters are known, it will add value for a strong, but detachable connection between the implant and abutment. Short implants and flat-to-flat connections especially will benefit significantly from this knowledge.
引用
收藏
页码:E25 / E32
页数:8
相关论文
共 50 条
  • [41] The implant-abutment interface of alumina and zirconia abutments
    Yuezueguellue, Bulem
    Avci, Mehmet
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2008, 10 (02) : 113 - 121
  • [42] Persistent acute inflammation at the implant-abutment interface
    Broggini, N
    McManus, LM
    Hermann, JS
    Medina, RU
    Oates, TW
    Schenk, RK
    Buser, D
    Mellonig, JT
    Cochran, DL
    JOURNAL OF DENTAL RESEARCH, 2003, 82 (03) : 232 - 237
  • [43] IMPLANT-ABUTMENT INTERFACE: A COMPARISON OF THE ULTIMATE FORCE TO FAILURE AMONG NARROW-DIAMETER IMPLANT SYSTEMS
    Imam, Ahmad Y.
    Moshaverinia, Alireza
    McGlumphy, Edwin A.
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (02): : 136 - 142
  • [44] Influence of design and clinical factors on the removal force ratio in tapered implant-abutment interfaces
    Aguirrebeitia, Josu
    Abasolo, Mikel
    Mueftue, Sinan
    Vallejo, Javier
    JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (04): : 493 - 498
  • [45] Preventing loosening of implant abutment screws
    Cavazos, E
    Bell, FA
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05): : 566 - 569
  • [46] Molecular leakage at implant-abutment connection—in vitro investigation of tightness of internal conical implant-abutment connections against endotoxin penetration
    Sönke Harder
    Birka Dimaczek
    Yaha Açil
    Hendrik Terheyden
    Sandra Freitag-Wolf
    Matthias Kern
    Clinical Oral Investigations, 2010, 14 : 427 - 432
  • [47] Stability and aging resistance of a zirconia oral implant using a carbon fiber-reinforced screw for implant-abutment connection
    Spies, Benedikt C.
    Fross, Alexander
    Adolfsson, Erik
    Bagegni, Aimen
    Doerken, Sam
    Kohal, Ralf-Joachim
    DENTAL MATERIALS, 2018, 34 (10) : 1585 - 1595
  • [48] The effect of the digital manufacturing technique of cantilevered implant-supported frameworks on abutment screw preload
    Altuwaijri, Shahad Mohammmed
    Alotaibi, Hanan Nejer
    Alnassar, Talal Mughaileth
    JOURNAL OF ADVANCED PROSTHODONTICS, 2022, 14 (01): : 22 - 31
  • [49] Histology of a dental implant with a platform switched implant-abutment connection
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF OSSEOINTEGRATION, 2011, 3 (03) : 56 - 60
  • [50] A classification system to measure the implant-abutment microgap
    Kano, Stefania C.
    Binon, Paul P.
    Curtis, Donald A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2007, 22 (06) : 879 - 885