Head-to-head comparison between flash and continuous glucose monitoring systems in outpatients with type 1 diabetes

被引:80
|
作者
Bonora, B. [1 ]
Maran, A. [1 ]
Ciciliot, S. [1 ]
Avogaro, A. [1 ]
Fadini, G. P. [1 ]
机构
[1] Univ Padua, Div Metab Dis, Dept Med, Via Giustiniani 2, I-35128 Padua, Italy
来源
关键词
Sensors; Continuous glucose monitoring; Hypoglycaemia; Variability; Calibration; BLOOD-GLUCOSE; VARIABILITY; INSTABILITY; ADOLESCENTS; FREQUENCY; ACCURACY; CHILDREN; INDEX;
D O I
10.1007/s40618-016-0495-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Continuous glucose monitoring (CGM) is being increasingly used in clinical practice. The flash glucose monitoring (FGM) and CGM are different systems of interstitial glucose recording. We aimed to determine the agreement between the factory-calibrated FGM FreeStyle Libre (FSL) and the gold-standard CGM Dexcom G4 Platinum (DG4P). We analyzed data from n = 8 outpatients with type 1 diabetes, who wore the FSL and DG4P for up to 14 days during their habitual life. We aligned FSL and DG4P recordings to obtain paired glucose measures. We calculated correlation coefficients, mean absolute relative difference (MARD), percentages in Clarke error grid areas, time spent in hyperglycaemia, target glycaemia, or hypoglycaemia, as well as glucose variability with both sensors. Comparison with self-monitoring of blood glucose (SMBG) was also performed. Patients varied in terms of age, diabetes duration, and HbA1c (from 5.9 to 9.6 %). In the pooled analysis of 10,020 paired values, there was a good correlation between FSL and DG4P (r (2) = 0.76; MARD = 18.1 +/- 14.8 %) with wide variability among patients. The MARD was significantly higher during days 11-14 than in days 1-10, and during hypoglycaemia (19 %), than in normoglycaemia (16 %) or hyperglycaemia (13 %). Average glucose profiles and MARD versus SMBG were similar between the two sensors. Time spent in normo-, hyper-, or hypoglycaemia, and indexes of glucose variability was similarly estimated by the two sensors. In outpatients with type 1 diabetes, we found good agreement between the FSL and DG4P. No significant difference was detected in the estimation of clinical diagnostic parameters.
引用
收藏
页码:1391 / 1399
页数:9
相关论文
共 50 条
  • [21] Comparison of continuous glucose monitoring and SMBG in unstable type 1 diabetes
    Papastathi, C.
    Reffet, S.
    Thivolet, C.
    DIABETES & METABOLISM, 2011, 37 : A107 - A107
  • [22] A Head-To-Head Comparison of Benzbromarone and Allopurinol on the Risk of Type 2 Diabetes Mellitus in People With Asymptomatic Hyperuricemia
    Lai, Shih-Wei
    Liao, Kuan-Fu
    Kuo, Yu-Hung
    Lin, Cheng-Li
    Liu, Chiu-Shong
    Hwang, Bing-Fang
    FRONTIERS IN PHARMACOLOGY, 2021, 12
  • [23] Use of Continuous Glucose Monitoring Systems in Children with Type 1 Diabetes
    Minnock, Pantea P.
    Howe, Carol J.
    CRITICAL CARE NURSING CLINICS OF NORTH AMERICA, 2011, 23 (02) : 273 - +
  • [24] Head-to-head comparison of quantitative measurements between intravascular imaging systems: An in vitro phantom study
    Nishi, Takeshi
    Imura, Shinji
    Kitahara, Hideki
    Kobayashi, Yoshio
    Yock, Paul G.
    Fitzgerald, Peter J.
    Honda, Yasuhiro
    IJC HEART & VASCULATURE, 2021, 36
  • [25] Continuous Glucose Monitoring and Type 1 Diabetes
    Montagnana, Martina
    Lippi, Giuseppe
    Guidi, Gian Cesare
    NEW ENGLAND JOURNAL OF MEDICINE, 2009, 360 (02): : 190 - 191
  • [26] Continuous glucose monitoring in type 1 diabetes
    Weinzimer S.A.
    Tamborlane W.V.
    Chase P.
    Garg S.K.
    Current Diabetes Reports, 2004, 4 (2) : 95 - 100
  • [27] Continuous glucose monitoring in type 1 diabetes
    Nelly Mauras
    Larry Fox
    Kimberly Englert
    Roy W. Beck
    Endocrine, 2013, 43 : 41 - 50
  • [28] Continuous glucose monitoring in type 1 diabetes
    Mauras, Nelly
    Fox, Larry
    Englert, Kimberly
    Beck, Roy W.
    ENDOCRINE, 2013, 43 (01) : 41 - 50
  • [29] Clinical Performance of Three Bolus Calculators in Twenty-Four Subjects with Type 1 Diabetes Mellitus: A Head-to-Head Comparison
    Freckmann, Guido
    Zisser, Howard
    Pleus, Stefan
    Haug, Cornelia
    Jendrike, Nina
    Parkin, Christopher
    Schweitzer, Matthias
    Wagner, Robin
    DIABETES, 2010, 59 : A145 - A145
  • [30] Caregiver satisfaction with the use of continuous glucose monitoring and flash glucose monitoring in very young children with type 1 diabetes
    Aouchiche, Karine
    Bernoux, Delphine
    Sadoul, Elisabeth Baechler
    Haine, Elsa
    Joubert, Florence
    Epstein, Sophie
    Galon, Noemie Faure
    Dalla-Vale, Fabienne
    Combe, Jean-Charles
    Samper, Martine
    Simonin, Gilbert
    Castets, Sarah
    Marquant, Emeline
    Vergier, Julia
    Reynaud, Rachel
    ARCHIVES DE PEDIATRIE, 2025, 32 (01): : 36 - 40