Videoassisted thrombectomy of mechanical prosthetic heart valves

被引:0
|
作者
Carrier, M
Pellerin, M
Dagenais, F
Perrault, LP
Petitclerc, R
Pelletier, LC
机构
[1] Montreal Heart Inst, Dept Surg, Quebec City, PQ, Canada
[2] Montreal Heart Inst, Dept Radiol, Quebec City, PQ, Canada
[3] Univ Montreal, Montreal, PQ H3C 3J7, Canada
来源
JOURNAL OF HEART VALVE DISEASE | 1999年 / 8卷 / 04期
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim of the study: Thrombosis of a bileaflet mechanical heart valve is a life-threatening clinical event. Surgical thrombectomy of bileaflet mechanical prostheses remains an appropriate treatment in selected patients. Methods: Between 1996 and 1998, five patients (three men, two women; average age 56 +/- 1 years; range: 56 to 66 years) with thrombosis of left-sided bileaflet mechanical valves were treated with videoassisted thrombectomy of the prosthesis. Four patients had thrombosis of a bileaflet mitral mechanical valve, and one patient had thrombosis of an aortic valve prosthesis. Preoperatively, patients were in either NYHA functional class IV (n = 4) or class I (n = 1). Surgery was performed through a right anterior thoracotomy or a median sternotomy. A rigid 30 degrees thoracoscope was inserted into the left atrium or aorta to visualize the thrombosed valve. The thrombus was extracted and the prosthesis under-surface examined and cleaned. Leaflet mobility, assessed with transesophageal echocardiography, was normal-following surgical thrombectomy. Results: Mean cardiopulmonary bypass time was 102 +/- 30 min; mean aortic cross-clamping time was 47 +/- 25 min. There was no hospital mortality; mean hospital stay was 9 +/- 1 days (range: 6 to 11 days). Anticoagulation with intravenous heparin was resumed 24 h after surgery. Three patients were discharged on coumarin treatment alone; two patients received aspirin plus coumarin. Mean postoperative follow up was 7 +/- 8 months (range: 1 to 21 months). One patient died 21 months after thrombectomy of a mitral prosthesis, with an unconfirmed diagnosis of recurrent mitral valve dysfunction. At 1-15 months after surgery, four patients are in NYHA class I, without evidence of prosthesis dysfunction. Conclusion: Videoassisted thrombectomy of bileaflet mechanical heart valve is a treatment option in patients with acute thrombosis of the prosthesis.
引用
收藏
页码:404 / 406
页数:3
相关论文
共 50 条
  • [21] Antithrombotic therapy in patients with mechanical and biological prosthetic heart valves
    Stein, PD
    Alpert, JS
    Dalen, JE
    Horstkotte, D
    Turpie, AGG
    CHEST, 1998, 114 (05) : 602S - 610S
  • [22] Spectral Analysis of Heart Sounds Produced by Disorder Mechanical Prosthetic Heart Valves
    Zhang, Di
    He, Jiazhong
    Yao, Jianping
    Wu, Zhongkai
    Du, Minghui
    PROCEEDINGS OF THE 2009 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS, VOLS 1-4, 2009, : 390 - +
  • [23] Evolution of prosthetic heart valves
    Edmunds, LH
    AMERICAN HEART JOURNAL, 2001, 141 (05) : 849 - 855
  • [24] DURABILITY OF PROSTHETIC HEART VALVES
    HYLEN, JC
    AMERICAN HEART JOURNAL, 1971, 81 (03) : 299 - &
  • [25] Rumbles and prosthetic heart valves
    Commerford, PJ
    Stevens, JE
    Millar, RS
    NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (17): : 1259 - 1260
  • [26] PROSTHETIC HEART VALVES IN CHILDREN
    JOHNSON, WD
    DAWES, RB
    GALLEN, WJ
    LEPLEY, D
    CIRCULATION, 1966, 34 (4S3) : I136 - &
  • [27] Anticoagulation for prosthetic heart valves
    Iqbal, O
    PROCEEDINGS OF THE 5TH WORLD CONGRESS OF ECHOCARDIOGRAPHY AND VASCULAR ULTRASOUND, 2001, : 73 - 77
  • [28] Prosthetic heart valves and pregnancy
    Roos-Hesselink, J. W.
    Ruys, P. T. E.
    Cuypers, J. A. A. E.
    FIRST INTERNATIONAL CONGRESS ON CARDIAC PROBLEMS IN PREGNANCY (CPP), 2010, : 47 - 51
  • [29] Complications of prosthetic heart valves
    Vesey J.M.
    Otto C.M.
    Current Cardiology Reports, 2004, 6 (2) : 106 - 111
  • [30] Prosthetic heart valves and pregnancy
    McLintock, C
    North, RA
    White, HD
    CIRCULATION, 2003, 108 (23) : E159 - E159