Flow system for liquid-solid extraction and pre-concentration using a renewable extracting solid phase

被引:0
|
作者
Neto, AC
Pasquini, C
机构
[1] Univ Estadual Campinas, Inst Quim, BR-13083970 Campinas, SP, Brazil
[2] Fac Engn Quim Lorena, Dept Mat Engn, BR-12600000 Lorena, SP, Brazil
关键词
renewable; photodiode; spectrophotometric;
D O I
10.1016/S0003-2670(02)00940-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A mechanised flow system is described aimed at extracting and pre-concentrating metal ions in a renewable water-insoluble solid phase containing a suitable ligand. The main difference between the proposed system and previously described ones for use with liquid-solid extraction is in the renewable characteristics of the solid phase, which allows for refreshing the extracting surface to be employed between pre-concentration operations. The renewable feature imposes no demands in terms of reversibility of the adsorption process as all the solid organic phase containing the complexed metal is dissolved by a non-aqueous solvent and carried to the detection system. Simultaneously, the system promotes a better compromise between metal extraction and pre-concentration as lower solvent volumes can be used to recover the absorbed species. The system has been evaluated for Zn(II) extraction in order to optimise its main geometrical and chemical variables. A simple spectrophotometric detection system employing a light emitting diode (LED) and a silicon photodiode was employed in these studies. Concentration gains of 42 and detection limits below 1.0 mugl(-1) were obtained. Sample throughput and sample consume depend on the desired pre-concentration. For higher (>40) concentration factors, about 40 ml of aqueous sample and a total processing time of 20 min per sample are required. (C) 2002 Elsevier Science B.V. 2002 Elsevier Science B.V. All rights reserved. All rights reserved.
引用
收藏
页码:141 / 146
页数:6
相关论文
共 50 条
  • [11] A highly selective solid phase extraction sorbent for pre-concentration of sameridine made by molecular imprinting
    L. I. Andersson
    A. Paprica
    T. Arvidsson
    Chromatographia, 1997, 46 : 57 - 62
  • [12] Pre-concentration of rosuvastatin using solid-phase extraction in a molecularly imprinted polymer and analytical application in water supply
    da Silva, Wanderson A.
    Feiteira, Fernanda N.
    Francisco, Janaina E.
    Toloza, Carlos A. T.
    Aucelio, Ricardo Q.
    Pacheco, Wagner F.
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2020, 27 (11) : 11724 - 11735
  • [13] Pre-concentration of rosuvastatin using solid-phase extraction in a molecularly imprinted polymer and analytical application in water supply
    Wanderson A. da Silva
    Fernanda N. Feiteira
    Janaína E. Francisco
    Carlos A. T. Toloza
    Ricardo Q. Aucélio
    Wagner F. Pacheco
    Environmental Science and Pollution Research, 2020, 27 : 11724 - 11735
  • [14] Ionic imprinted polymer based solid phase extraction for cadmium and lead pre-concentration/determination in seafood
    Barciela-Alonso, M. C.
    Plata-Garcia, V.
    Rouco-Lopez, A.
    Moreda-Pineiro, A.
    Bermejo-Barrera, P.
    MICROCHEMICAL JOURNAL, 2014, 114 : 106 - 110
  • [15] Multi-element pre-concentration of heavy metal ions by solid phase extraction on Chromosorb 108
    Tuzen, M
    Soylak, M
    Elci, L
    ANALYTICA CHIMICA ACTA, 2005, 548 (1-2) : 101 - 108
  • [16] LIQUID-SOLID PHASE TRANSITION
    AUSLAEND.GJ
    INDUSTRIAL & ENGINEERING CHEMISTRY FUNDAMENTALS, 1969, 8 (04): : 843 - &
  • [17] Concentration Profile Measurement of Liquid-Solid Two-Phase Horizontal Pipe Flow Using Ultrasound Doppler
    Zhang, Hanrui
    Dong, Feng
    Tan, Chao
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [18] INVESTIGATION OF TURBULENT PHASE MIXING IN A LIQUID-SOLID SYSTEM
    MARTSULEVICH, NA
    PROTODYAKONOV, IO
    ROMANKOV, PG
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1980, 53 (02): : 297 - 301
  • [19] PREDICTION OF VERTICAL LIQUID-SOLID PIPE-FLOW USING MEASURED CONCENTRATION DISTRIBUTION
    BARTOSIK, AS
    SHOOK, CA
    PARTICULATE SCIENCE AND TECHNOLOGY, 1995, 13 (02) : 85 - 104
  • [20] In-source fragmentation of an isobaric impurity of lamotrigine for its measurement by liquid chromatography tandem mass spectrometry after pre-concentration using solid phase extraction
    Carrier, Dan J.
    Eckers, Christine
    Wolff, Jean-Claude
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 731 - 737