The Analysis of Tear Meniscus in Soft Contact Lens Wearers by Spectral Optical Coherence Tomography

被引:10
|
作者
Le, Qihua [1 ]
Jiang, Chunhui [1 ]
Jiang, Alice C. [2 ]
Xu, Jianjiang [1 ]
机构
[1] Fudan Univ, Eye & ENT Hosp, Dept Ophthalmol, Shanghai 200031, Peoples R China
[2] Univ Wisconsin, Madison, WI 53706 USA
关键词
tear meniscus; soft contact lens; spectral optical coherence tomography; LIPID LAYER; CONFOCAL MICROSCOPY; SCHIRMER TEST; FILM; REPEATABILITY; EVAPORATION; PARAMETERS; THICKNESS; DYNAMICS; HEIGHT;
D O I
10.1097/ICO.0b013e318197ec24
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the changes of tear meniscus in eyes fitted with soft contact lens (SCL) by spectral optical coherence tomography (SOCT). Methods: Thirty-three contact lens wearers who wore daily-wear frequent-replacement SCL with 55% water content for more than 6 years on average, and 33 normal subjects were enrolled in this study. The meniscus at the central lower lid of the left eye was examined by SOCT. For the lens wearers, the examination was performed twice: once with contact lens and once without. For the non-lens wearers, the examination was performed only once. The image of lower tear meniscus was divided into two parts: the hyperreflective curved layer (PI) and the hyporeflective triangular area (P2). The height of PI and P2 (H-PI and H-P2) was measured, along with the thickness and area of both parts (T-[P1+P2] and A-[P1+P2]). Results: The cornea, lower eyelid, contact lens, and the lower tear meniscus could be clearly visualized in the SOCT images. For the lens wearers, the mean values of H-P1, H-P2, T-[P1+P2], and A-[P1+P2] measured before removing the lenses were 164.18 +/- 41.77 mu m, 148.6 +/- 42.84 mu m, 134.72 +/- 38.39 mu m, and 9914 +/- 469 mu m(2). The values of these parameters measured after lens removal showed no significant differences from those measured with the lens. Variables tested in lens-wearers with and without contact lenses were both significantly lower than those of normal subjects. Conclusions: SOCT can be helpful in evaluation of the lower tear meniscus in the eye fitted with a SCL. Long-term SCL wear could induce decreased tear volume, especially by reduction of the aqueous component.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [21] Reliability of Tear Meniscus Height Measurements in Contact Lens Wearers and Its Relationship With Discomfort Symptoms
    Valencia-Nieto, Laura
    Lopez-de la Rosa, Alberto
    Lopez-Miguel, Alberto
    Gonzalez-Garcia, Maria J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2024, 50 (09): : 410 - 415
  • [22] TEAR BUFFERING IN CONTACT-LENS WEARERS
    CARNEY, LG
    MAUGER, TF
    HILL, RM
    ACTA OPHTHALMOLOGICA, 1990, 68 (01): : 75 - 79
  • [23] Analysis of Tear Meniscus Change after Strabismus Surgery Using Optical Coherence Tomography
    Kim, Ji Hye
    Kim, Che Ron
    Kim, Seong Jae
    Chung, In Young
    Seo, Seong Wook
    Yoo, Ji Myong
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2016, 57 (12): : 1932 - 1938
  • [24] Measuring of Corneal Thickness of Contact Lens Wearers with Keratoconus and Keratoplasty by Means of Optical Coherence Tomography (OCT)
    Poeltner, Gustav
    Miller, Klaus
    Berke, Andreas
    Sickenberger, Wolfgang
    COLLEGIUM ANTROPOLOGICUM, 2013, 37 : 165 - 173
  • [25] Spectral domain optical coherence tomography for measuring tear film meniscus height and its relationship with epiphora
    Singh, Swati
    Rajput, Anu
    Mohamed, Ashik
    Mittal, Vikas
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (11) : 1592 - 1594
  • [26] The effect of contact lens wear on retinal spectral domain optical coherence tomography
    Aviram, Talia
    Beeri, Idan
    Berkow, David
    Zayit-Soudry, Shiri
    Blumenthal, Eytan Z.
    Shapira, Yinon
    CLINICAL AND EXPERIMENTAL OPTOMETRY, 2020, 103 (06) : 792 - 797
  • [27] Spectral optical coherence tomography: a new imaging technique in contact lens practice
    Kaluzny, BJ
    Kaluzny, JJ
    Szkulmowska, A
    Gorczynska, I
    Szkulmowski, M
    Bajraszewski, T
    Targowski, P
    Kowalczyk, A
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2006, 26 (02) : 127 - 132
  • [28] Lower tear meniscus height measured by optical coherence tomography in children
    Martin-Garcia, Beatriz
    Palomo-Alvarez, Catalina
    Piedrahita-Alonso, Elena
    Gomez-de-Liano, Rosario
    Ferrer, Manuel Enrique Fuentes
    Arriola-Villalobos, Pedro
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2023, 43 (05) : 1059 - 1064
  • [29] Tear Meniscus Height by Optical Coherence Tomography (OCT) and Ocular Itch
    Hom, Milton M.
    Nguyen, Andrew
    Bielory, Leonard
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2013, 131 (02) : AB113 - AB113
  • [30] Interexaminer Reproducibility of Optical Coherence Tomography for Measuring the Tear Film Meniscus
    Canan, Handan
    Altan-Yaycioglu, Rana
    Ulas, Burak
    Sizmaz, Selcuk
    Coban-Karatas, Muge
    CURRENT EYE RESEARCH, 2014, 39 (12) : 1145 - 1150