Potential of magnetic resonance-guided focused ultrasound for intracranial hemorrhage: an in vitro feasibility study

被引:3
|
作者
Harnof, Sagi [1 ]
Hananel, Arik [2 ]
Zilby, Zion [3 ]
Kulbatski, Iris [4 ]
Hadani, Moshe [1 ]
Kassell, Neal [5 ]
机构
[1] Chaim Sheba Med Ctr, Dept Neurosurg, IL-52621 Tel Hashomer, Israel
[2] FUS Fdn, Charlottesville, VA USA
[3] NCI, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
[4] Toronto Western Res Inst, Dept Genet & Dev, Toronto, ON M5T 2S8, Canada
[5] Univ Virginia, Dept Neurosurg, Charlottesville, VA USA
关键词
intracranial hemorrhage; magnetic resonance-guided focused ultrasound; noninvasive; stroke; thrombolysis; BRAIN; THROMBOLYSIS; SURGERY; ABLATION; SYSTEM; RABBIT;
D O I
10.1111/ijs.12051
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Intracranial hemorrhage has a mortality rate of up to 40-60% due to the lack of effective treatment. Magnetic resonance-guided focused ultrasound may offer a breakthrough noninvasive technology, by allowing accurate delivery of focused ultrasound, under the guidance of real-time magnetic resonance imaging. Aim The purpose of the current study was to optimize the acoustic parameters of magnetic resonance-guided focused ultrasound for effective clot liquefaction, in order to evaluate the feasibility of magnetic resonance-guided focused ultrasound for thrombolysis. Methods Body (11MHz) and brain (220kHz) magnetic resonance-guided focused ultrasound systems (InSightec Ltd, Tirat Carmel, Israel) were used to treat tube-like (4cc), round (10cc), and bulk (300cc) porcine blood clots in vitro, using burst sonications of one-second to five-seconds, a duty cycle of 5-50%, and peak acoustic powers between 600 and 1200W. Liquefied volumes were measured as hyperintense regions on T2-weighted magnetic resonance images for body unit sonications (duration of one-second, duty cycle of 10%, and power of 500-1200W). Liquefaction efficiency was calculated for brain unit sonications (duration of one-second, duty cycle of 10%, power of 600W, and burst length between 01ms and 100ms). Results Liquified lesion volume increased as power was raised, without a thermal rise. For brain unit sonications, a power setting of 600W and ultrashort sonications (burst length between 01 and 10ms) resulted in liquefaction efficacy above 50%, while longer burst duration yielded lower efficacy. Conclusions These results demonstrate the feasibility of obtaining reproducible, rapid, efficient, and accurate blood clot lysis using the magnetic resonance-guided focused ultrasound system. Further in vivo studies are needed to validate the feasibility of magnetic resonance-guided focused ultrasound as a treatment modality for intracranial hemorrhage.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [31] UNILATERAL MAGNETIC RESONANCE-GUIDED FOCUSED ULTRASOUND PALLIDOTOMY FOR PARKINSON DISEASE
    Na, Young Cheol
    Chang, Won Seok
    Jung, Hyun Ho
    Kweon, Eun Jung
    Chang, Jin Woo
    NEUROLOGY, 2015, 85 (06) : 549 - 551
  • [32] Magnetic resonance-guided, high-intensity focused ultrasound sonolysis: potential applications for stroke
    Ilyas, Adeel
    Chen, Ching-Jen
    Ding, Dale
    Romeo, Andrew
    Buell, Thomas J.
    Wang, Tony R.
    Kalani, M. Yashar S.
    Park, Min S.
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [33] Magnetic Resonance-Guided Focused Ultrasound Thalamotomy for Focal Hand Dystonia: A Pilot Study
    Horisawa, Shiro
    Yamaguchi, Toshio
    Abe, Keiichi
    Hori, Hiroki
    Fukui, Atsushi
    Iijima, Mutsumi
    Sumi, Masatake
    Hodotsuka, Kenichi
    Konishi, Yoshiyuki
    Kawamata, Takakazu
    Taira, Takaomi
    MOVEMENT DISORDERS, 2021, 36 (08) : 1955 - 1959
  • [34] Volumetric analysis of magnetic resonance-guided focused ultrasound thalamotomy lesions
    Harary, Maya
    Essayed, Walid I.
    Valdes, Pablo A.
    McDannold, Nathan
    Cosgrove, G. Rees
    NEUROSURGICAL FOCUS, 2018, 44 (02)
  • [35] Technical Eligibility for Treatment of Magnetic Resonance-guided Focused Ultrasound Surgery
    Froeling, V.
    Kroencke, T. J.
    Schreiter, N. F.
    Scheurig-Muenkler, C.
    Collettini, F.
    Hamm, B.
    Beck, A.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2014, 37 (02) : 445 - 450
  • [36] Magnetic resonance-guided focused ultrasound for palliation of painful bone metastases
    Turkevich, V. G.
    Savelyeva, V. V.
    Dunaevsky, I. V.
    Krzhivitsky, P. I.
    Dogadkin, O.
    Bernstein, M.
    Kanaev, S. V.
    EJC SUPPLEMENTS, 2009, 7 (02): : 172 - 172
  • [37] Magnetic Resonance-Guided focused Ultrasound A new Option for Tremor Treatment
    Purrer, V.
    Keil, V. C.
    Groetz, S.
    Hamed, M.
    Upadhyay, N.
    Faber, J.
    Boecker, H.
    Borger, V.
    Pieper, C.
    Wuellner, U.
    NERVENARZT, 2019, 90 (04): : 408 - 411
  • [38] Magnetic Resonance-Guided Focused Ultrasound A New Technology for Clinical Neurosciences
    Jolesz, Ferenc A.
    McDannold, Nathan J.
    NEUROLOGIC CLINICS, 2014, 32 (01) : 253 - +
  • [39] What factors currently limit magnetic resonance-guided focused ultrasound of leiomyomas? A survey conducted at the first international symposium devoted to clinical magnetic resonance-guided focused ultrasound
    Taran, F. Andrei
    Hesley, Gina K.
    Gorny, Krzysztof R.
    Stewart, Elizabeth A.
    FERTILITY AND STERILITY, 2010, 94 (01) : 331 - 334
  • [40] A long arm for ultrasound: A combined robotic focused ultrasound setup for magnetic resonance-guided focused ultrasound surgery
    Krafft, Axel J.
    Jenne, Juergen W.
    Maier, Florian
    Stafford, R. Jason
    Huber, Peter E.
    Semmler, Wolfhard
    Bock, Michael
    MEDICAL PHYSICS, 2010, 37 (05) : 2380 - 2393