Potential of magnetic resonance-guided focused ultrasound for intracranial hemorrhage: an in vitro feasibility study

被引:3
|
作者
Harnof, Sagi [1 ]
Hananel, Arik [2 ]
Zilby, Zion [3 ]
Kulbatski, Iris [4 ]
Hadani, Moshe [1 ]
Kassell, Neal [5 ]
机构
[1] Chaim Sheba Med Ctr, Dept Neurosurg, IL-52621 Tel Hashomer, Israel
[2] FUS Fdn, Charlottesville, VA USA
[3] NCI, Radiat Oncol Branch, NIH, Bethesda, MD 20892 USA
[4] Toronto Western Res Inst, Dept Genet & Dev, Toronto, ON M5T 2S8, Canada
[5] Univ Virginia, Dept Neurosurg, Charlottesville, VA USA
关键词
intracranial hemorrhage; magnetic resonance-guided focused ultrasound; noninvasive; stroke; thrombolysis; BRAIN; THROMBOLYSIS; SURGERY; ABLATION; SYSTEM; RABBIT;
D O I
10.1111/ijs.12051
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background Intracranial hemorrhage has a mortality rate of up to 40-60% due to the lack of effective treatment. Magnetic resonance-guided focused ultrasound may offer a breakthrough noninvasive technology, by allowing accurate delivery of focused ultrasound, under the guidance of real-time magnetic resonance imaging. Aim The purpose of the current study was to optimize the acoustic parameters of magnetic resonance-guided focused ultrasound for effective clot liquefaction, in order to evaluate the feasibility of magnetic resonance-guided focused ultrasound for thrombolysis. Methods Body (11MHz) and brain (220kHz) magnetic resonance-guided focused ultrasound systems (InSightec Ltd, Tirat Carmel, Israel) were used to treat tube-like (4cc), round (10cc), and bulk (300cc) porcine blood clots in vitro, using burst sonications of one-second to five-seconds, a duty cycle of 5-50%, and peak acoustic powers between 600 and 1200W. Liquefied volumes were measured as hyperintense regions on T2-weighted magnetic resonance images for body unit sonications (duration of one-second, duty cycle of 10%, and power of 500-1200W). Liquefaction efficiency was calculated for brain unit sonications (duration of one-second, duty cycle of 10%, power of 600W, and burst length between 01ms and 100ms). Results Liquified lesion volume increased as power was raised, without a thermal rise. For brain unit sonications, a power setting of 600W and ultrashort sonications (burst length between 01 and 10ms) resulted in liquefaction efficacy above 50%, while longer burst duration yielded lower efficacy. Conclusions These results demonstrate the feasibility of obtaining reproducible, rapid, efficient, and accurate blood clot lysis using the magnetic resonance-guided focused ultrasound system. Further in vivo studies are needed to validate the feasibility of magnetic resonance-guided focused ultrasound as a treatment modality for intracranial hemorrhage.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 50 条
  • [1] Potential of Magnetic Resonance-guided Focused Ultrasound for Intracranial Hemorrhage: An In Vivo Feasibility Study
    Harnof, Sagi
    Zibly, Zion
    Hananel, Arik
    Monteith, Stephen
    Grinfeld, Javier
    Schiff, Gilat
    Kulbatski, Iris
    Kassell, Neal
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2014, 23 (06): : 1585 - 1591
  • [2] Potential intracranial applications of magnetic resonance-guided focused ultrasound surgery
    Monteith, Stephen
    Sheehan, Jason
    Medel, Ricky
    Wintermark, Max
    Eames, Matthew
    Snell, John
    Kassell, Neal F.
    Elias, W. Jeff
    JOURNAL OF NEUROSURGERY, 2013, 118 (02) : 215 - 221
  • [3] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Nir Lipsman
    Todd G. Mainprize
    Michael L. Schwartz
    Kullervo Hynynen
    Andres M. Lozano
    Neurotherapeutics, 2014, 11 : 593 - 605
  • [4] Intracranial Applications of Magnetic Resonance-guided Focused Ultrasound
    Lipsman, Nir
    Mainprize, Todd G.
    Schwartz, Michael L.
    Hynynen, Kullervo
    Lozano, Andres M.
    NEUROTHERAPEUTICS, 2014, 11 (03) : 593 - 605
  • [5] Magnetic resonance-guided focused ultrasound
    Albuquerque, Felipe C.
    NEUROSURGICAL FOCUS, 2013, 34 (05)
  • [6] Magnetic Resonance-Guided Focused Ultrasound Surgery
    Al Hilli, Mariam M.
    Stewart, Elizabeth A.
    SEMINARS IN REPRODUCTIVE MEDICINE, 2010, 28 (03) : 241 - 248
  • [7] Magnetic resonance-guided focused ultrasound surgery
    Hudson, Susan B. A.
    Stewart, Elizabeth A.
    CLINICAL OBSTETRICS AND GYNECOLOGY, 2008, 51 (01): : 159 - 166
  • [8] Transcranial magnetic resonance-guided focused ultrasound for temporal lobe epilepsy: a laboratory feasibility study
    Monteith, Stephen
    Snell, John
    Eames, Mathew
    Kassel, Neal F.
    Kelly, Edward
    Gwinn, Ryder
    JOURNAL OF NEUROSURGERY, 2016, 125 (06) : 1557 - 1564
  • [9] Magnetic Resonance-Guided Focused Ultrasound for Psychiatric Disorders
    Davidson, Benjamin
    Meng, Ying
    Giacobbe, Peter
    Hamani, Clement
    Lipsman, Nir
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2019, 106 (04) : 720 - 722
  • [10] Magnetic resonance-guided focused ultrasound and essential tremor
    Gallay, Marc
    Jeanmonod, Daniel
    NEUROSURGICAL FOCUS, 2018, 45 (01)