Bioelectrical impedance analysis before and after Novacor implantation

被引:1
|
作者
Stellato, D
Cirillo, M
De Santo, LS
Maiello, C
Marra, C
de Vivo, F
Anastasio, P
Di Iorio, B
机构
[1] Seconda Univ Napoli, Cattedra Nefrol, Div Nephrol, I-80131 Naples, Italy
[2] Second Univ Napoli, Div Cardiac Surg, Naples, Italy
[3] Lauria Gen Hosp, Div Nephrol, Lauria, Italy
来源
关键词
bioelectrical impedance analysis; heart failure; Novacor; reactance; extracellular space;
D O I
10.1177/039139889902200307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study Bioelectrical Impedance Analysis was performed in 5 patients with end stage heart failure in whom a left ventricular assist device (Novacor) was successfully implanted. Whole body measurements of bioelectrical indices resistance and reactance were taken before surgery and 3, 7, 12, and 15 days after if. After surgery there was a significant decrease in reactance, indicating a shift of body fluids from intra- to extra-cellular space.
引用
收藏
页码:151 / 154
页数:4
相关论文
共 50 条
  • [21] Bioelectrical impedance analysis in dialysis patients
    Pupim, LB
    Kent, P
    Ikizler, TA
    MINERAL AND ELECTROLYTE METABOLISM, 1999, 25 (4-6) : 400 - 406
  • [22] Bioelectrical impedance analysis in nutritional research
    Han, TS
    Lean, MEJ
    NUTRITION, 1998, 14 (09) : 707 - 708
  • [23] Bioelectrical impedance analysis principles and methods
    Kyle, UG
    Bosaeus, I
    De Lorenzo, AD
    Deurenberg, P
    Elia, M
    Gómez, JM
    Heitmann, BL
    Kent-Smith, L
    Melchior, JC
    Pirlich, M
    Scharfetter, H
    Schols, AMWJ
    Pichard, C
    CLINICAL NUTRITION, 2004, 23 (05) : 1226 - 1243
  • [24] Bioelectrical Impedance Analysis - a Comparison Method
    Sekli, Elisabeth
    Kruschitz, Renate
    Luger, Maria
    Langer, Felix
    Prager, Gerhard
    Kefurt, Ronald
    Krebs, Michael
    Ludvik, Bernhard
    Schindler, Karin
    WIENER KLINISCHE WOCHENSCHRIFT, 2015, 127 (17-18) : 746 - 747
  • [25] Bioelectrical impedance analysis in ICU patients
    L Steinhilp
    F Bubser
    S Wiesener
    C Spies
    M Boschmann
    T Schütz
    S Weber-Carstens
    Critical Care, 13 (Suppl 1):
  • [26] Bioelectrical impedance analysis in the assessment of sarcopenia
    Cristina Gonzalez, M.
    Barbosa-Silva, Thiago G.
    Heymsfield, Steven B.
    CURRENT OPINION IN CLINICAL NUTRITION AND METABOLIC CARE, 2018, 21 (05): : 366 - 374
  • [27] BIOELECTRICAL IMPEDANCE
    GEDDES, LA
    SCIENCE, 1970, 167 (3926) : 1761 - &
  • [28] Bioelectrical impedance analysis measurements for drug pharmacokinetics
    Zarowitz, BJ
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1996, 64 (03): : 519 - 523
  • [29] Bioelectrical impedance analysis in body composition measurement
    不详
    NUTRITION, 1996, 12 (11-12) : 749 - 759