High-Speed X-ray Phase Tomography with Talbot Interferometer and Fringe Scanning Method

被引:12
|
作者
Kibayashi, Shunsuke [1 ]
Harasse, Sebastien [2 ]
Yashiro, Wataru [2 ]
Momose, Atsushi [2 ]
机构
[1] Univ Tokyo, Dept Appl Phys, Fac Engn, 5-1-5 Kashiwanoha, Kashiwa, Chiba 2778561, Japan
[2] Univ Tokyo, Grad Sch Frontier Sci, Dept Adv Mat Sci, Tokyo 1138654, Japan
基金
日本科学技术振兴机构;
关键词
Phase imaging; Grating; Interferometer; Talbot interferometer; Tomography; Time resolved observation; WHITE SYNCHROTRON-RADIATION;
D O I
10.1063/1.4742302
中图分类号
O59 [应用物理学];
学科分类号
摘要
High-speed X-ray phase tomography based on the Fourier-transform method has been demonstrated with an X-ray Talbot interferometer using white synchrotron radiation. We report the experimental results of high-speed X-ray phase tomography with fringe-scanning method instead of Fourier-transform method to improve spatial resolution without a considerable increase of scan time. To apply fringe-scanning method to high speed tomography, we tested a scan that is a synchronous combination of one-way continuous movements of the sample rotation and the grating displacement. When this scanning method was combined with X-ray phase tomography, we were able to obtain a scan time of 5 s. A comparison of the image quality derived with the conventional approach and with the proposed approach using the fringe-scanning method showed that the latter had better spatial resolution.
引用
收藏
页码:261 / 265
页数:5
相关论文
共 50 条
  • [1] High-speed X-ray phase imaging and X-ray phase tomography with Talbot interferometer and white synchrotron radiation
    Momose, Atsushi
    Yashiro, Wataru
    Maikusa, Hirohide
    Takeda, Yoshihiro
    OPTICS EXPRESS, 2009, 17 (15): : 12540 - 12545
  • [2] X-ray Talbot-Lau Interferometer for High-Speed Phase Imaging and Tomography Using White Synchrotron Radiation
    Olbinado, Margie P.
    Harasse, Sebastien
    Yashiro, Wataru
    Momose, Atsushi
    INTERNATIONAL WORKSHOP ON X-RAY AND NEUTRON PHASE IMAGING WITH GRATINGS, 2012, 1466 : 266 - 271
  • [3] Phase tomography using X-ray Talbot interferometer
    Momose, A.
    Yashiro, W.
    Takeda, Y.
    Moritake, M.
    Uesugi, K.
    Suzuki, Y.
    Hattori, T.
    SYNCHROTRON RADIATION INSTRUMENTATION, PTS 1 AND 2, 2007, 879 : 1365 - +
  • [4] Phase tomography using an X-ray Talbot interferometer
    Momose, A
    Kawamoto, S
    Koyama, I
    Suzuki, Y
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 352 - 360
  • [5] X-ray phase tomography with a Talbot interferometer in combination with an X-ray imaging microscope
    Momose, Atsushi
    Takeda, Yoshihiro
    Yashiro, Wataru
    Takeuchi, Akihisa
    Suzuki, Yoshio
    9TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2009, 186
  • [6] Sensitivity of X-ray Phase Tomography Based on Talbot and Talbot-Lau Interferometer
    Momose, Atsushi
    Yashiro, Wataru
    Takeda, Yoshihiro
    Maikusa, Norihide
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VI, 2008, 7078
  • [7] X-ray Phase Laminography with Talbot Interferometer
    Harasse, Sebastien
    Hirayama, Nozomi
    Yashiro, Wataru
    Momose, Atsushi
    DEVELOPMENTS IN X-RAY TOMOGRAPHY VII, 2010, 7804
  • [8] Millisecond-order X-ray phase tomography with a fringe-scanning method
    Yashiro, Wataru
    Kamezawa, Chika
    Noda, Daiji
    Kajiwara, Kentaro
    APPLIED PHYSICS EXPRESS, 2018, 11 (12)
  • [9] High-speed X-ray ptychographic tomography
    Darren Batey
    Christoph Rau
    Silvia Cipiccia
    Scientific Reports, 12
  • [10] High-speed X-ray ptychographic tomography
    Batey, Darren
    Rau, Christoph
    Cipiccia, Silvia
    SCIENTIFIC REPORTS, 2022, 12 (01)