In cemented total hip prostheses, the role of creep of the acrylic cement (polymethyl methacrylate, [PMMA]) in increasing or decreasing the chance of failure of the cement mantle is a subject of ongoing controversy. Ln the present study we used a three-dimensional finite-element model of a cemented stem to assess the influence of cement creep on subsidence of the stem, and on the stress and strain in the cement under cyclic load, both in the short and long term. The cement layer was assigned the shear and bulk creep moduli of Zimmer regular PMMA cement, which were obtained experimentally. The stem-cement interface was modeled either as (1) completely bonded, (2) completely debonded with friction, or (3) completely debonded and frictionless. Under the cyclic load some cement creep occurred with all three bonding conditions, allowing additional subsidence of the stem and a decrease in the stress components within the cement. During the unloaded period the full recovery of the preload conditions could be reached with the completely bonded and with the frictionless interfaces. With the frictional interface there was residual cement creep, residual stresses within the cement, and residual subsidence of the stem during the unloaded period; however, the reduction of the stress was at most 13% and the subsidence was about 0.46 mm. The much larger subsidence of debonded stems that is often observed clinically might be attributed to the factors which were not included in the present model, such as circumferential bone remodeling. (C) 1997 John Wiley & Sons, Inc.
引用
收藏
页码:221 / 226
页数:6
相关论文
共 50 条
  • [21] Influence of cement viscosity and cement mantle thickness on migration of the Exeter total hip prosthesis
    Nelissen, RGHH
    Garling, EH
    Valstar, ER
    JOURNAL OF ARTHROPLASTY, 2005, 20 (04): : 521 - 528
  • [22] TOTAL HIP-REPLACEMENT WITHOUT BONE CEMENT
    MAEZAWA, H
    SASADA, T
    ARTIFICIAL ORGANS, 1977, 1 (01) : 133 - 133
  • [23] The effects of glenoid component alignment variations on cement mantle stresses in total shoulder arthroplasty
    Hopkins, AR
    Hansen, UN
    Amis, AA
    Emery, R
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (06) : 668 - 675
  • [24] Thickness effects on maximum von-Mises stress of a cement mantle in total hip replacement - a finite element study
    Kumar, Y. S. Arun
    Pant, Bhaskar
    Singh, Konjengbam Darunkumar
    JOURNAL OF APPLIED BIOMATERIALS & BIOMECHANICS, 2009, 7 (02) : 111 - 115
  • [25] The effects of acetabular cup temperature and duration of cement pressurization on cement porosity in a canine total hip replacement model
    Shields, SL
    Schulz, KS
    Hagan, CE
    Kass, P
    VETERINARY SURGERY, 2002, 31 (02) : 167 - 173
  • [26] Optimizing the femoral component cement mantle in total hip arthroplasty
    Dennis, DA
    Lynch, CB
    ORTHOPEDICS, 2005, 28 (08) : S867 - S871
  • [27] THE EFFECT OF FEMORAL STEM CROSS-SECTIONAL GEOMETRY ON CEMENT STRESSES IN TOTAL HIP RECONSTRUCTION
    CROWNINSHIELD, RD
    BRAND, RA
    JOHNSTON, RC
    MILROY, JC
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1980, (146) : 71 - 77
  • [28] Effects of distal cement voids on cement stress in total hip arthroplasty
    Powers, CM
    Lee, IY
    Skinner, HB
    Keyak, JH
    JOURNAL OF ARTHROPLASTY, 1998, 13 (07): : 793 - 798
  • [29] Thermal effects of cement mantle thickness for hip resurfacing
    Little, J. Paige
    Gray, Hans A.
    Murray, David W.
    Beard, David J.
    Gill, Harinderjit Singh
    JOURNAL OF ARTHROPLASTY, 2008, 23 (03): : 454 - 458
  • [30] Subsidence and the cement mantle in femoral impaction allografting
    Masterson, EL
    Duncan, CP
    ORTHOPEDICS, 1997, 20 (09) : 821 - 822