Numerical study of the effect of flow nonuniformities on the low-pressure side of a Cooled Cooling Air heat exchanger

被引:7
|
作者
Pandey, Sudhanshu [1 ]
Kallath, Hariharan [1 ]
Choi, Ho Yeon [2 ]
Sibilli, Thierry [3 ]
Min, June Kee [1 ]
Chetwynd-Chatwin, Jason [4 ]
Ha, Man Yeong [1 ]
机构
[1] Pusan Natl Univ, Sch Mech Engn, 2, Busandaehak ro 63beon gil, Pusan, South Korea
[2] Air Solut R&D Lab, LG Elect, Gyeongnam, South Korea
[3] SAFRAN SA, Dept Energy & Prop, Safran Tech, Magny les hameaux, France
[4] Rolls Royce plc, Whittle House,POB 3, Bristol BS34 7QE, England
关键词
Cooled Cooling Air; Flow nonuniformity; Heat exchanger; Numerical simulation; MODEL; DROP;
D O I
10.1016/j.applthermaleng.2022.119113
中图分类号
O414.1 [热力学];
学科分类号
摘要
The Cooled Cooling Air (CCA) heat exchanger is a precooler that cools the bleed air from the compressor stages and is located inside the bypass duct of the aeroengine. Nonuniform flows enter the core of the heat exchanger because the cold side is the off-take from the fan flow, compromising its aerothermal performance. These aspects has been disregarded in the literature until now. In this study, the aerothermal performance of a CCA heat exchanger with flow nonuniformities on its Low-Pressure (LP) side is investigated. Three-wire meshes were designed using correlations from the literature, showing three off-design cases, namely, Cases 1, 2, and 3. The porous media and dual cell heat exchanger models were used in numerical simulations for the baseline and off-design cases. Experiments were performed at hot and cold conditions to validate the numerical simulations under actual gas turbine operating conditions. It has been found that heat transfer rate increases in Case 1 and 2 by 1.0% and 1.5%, as the flow non-uniformity is symmetric with respect to XZ plane. In contrast, in Case 3, the heat transfer rate reduces by 4.2% because the flow non-uniformity is asymmetric with respect to XZ plane, inducing cross-flows immediately upstream of the heat exchanger core.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Numerical Study of the Flow Uniformity Inside the High-Pressure Side Manifolds of a Cooled Cooling Air Heat Exchanger
    Kallath, Hariharan
    Kholi, Foster Kwame
    Jin, Qingye
    Ha, Man Yeong
    Park, Sang Hu
    Kim, Hyeon-jun
    Chetwynd-Chatwin, Jason
    Min, June Kee
    APPLIED THERMAL ENGINEERING, 2021, 189
  • [2] Study on the air-side flow and heat transfer characteristics of corrugated fin under low-pressure environment
    Li, Ya-Wen
    Wang, Yi-Chun
    Wan, Rui
    Liu, Zhen
    Wu, Hua-Wei
    Mei, Xue-Qing
    EXPERIMENTAL HEAT TRANSFER, 2022, 35 (01) : 62 - 78
  • [3] Numerical Study of Fin-and-Tube Heat Exchanger in Low-Pressure Environment: Air-Side Heat Transfer and Frictional Performance, Entropy Generation Analysis, and Model Development
    Zhang, Lei
    Wang, Junwei
    Liu, Ran
    Li, Guohua
    Han, Xiao
    Zhang, Zhiqiang
    Zhao, Jiayi
    Dai, Baomin
    ENTROPY, 2022, 24 (07)
  • [4] Numerical simulation on flow and heat transfer of fin structure in air-cooled heat exchanger
    Li, Li
    Du, Xiaoze
    Yang, Lijun
    Xu, Yan
    Yang, Yongping
    APPLIED THERMAL ENGINEERING, 2013, 59 (1-2) : 77 - 86
  • [5] Effect of ambient pressure on air side heat transfer and flow characteristics of plain finned tube heat exchanger
    Zhang, Jiawen
    Liu, Jianhua
    Zhang, Liang
    Liu, Qi
    Wu, Qingqing
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 158
  • [6] Inhibition of corrosion in amine air cooled heat exchanger: Experimental and numerical study
    Valeh-e-Sheyda, Peyvand
    Rashidi, Hamed
    APPLIED THERMAL ENGINEERING, 2016, 98 : 1241 - 1250
  • [7] Design and numerical parametric study of a compact air-cooled heat exchanger
    Huang, Zhiwei
    Ling, Jiazhen
    Hwang, Yunho
    Aute, Vikrant
    Radermacher, Reinhard
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (06) : 970 - 982
  • [8] Numerical investigation of the effect of inlet flow distortions on forced draught air-cooled heat exchanger performance
    Meyer, CJ
    APPLIED THERMAL ENGINEERING, 2005, 25 (11-12) : 1634 - 1649
  • [9] Numerical modelling and parametric study of an air-cooled desiccant coated cross-flow heat exchanger
    Liu, Lin
    Zeng, Tao
    Huang, Hongyu
    Kubota, Mitsuhiro
    Kobayashi, Noriyuki
    He, Zhaohong
    Li, Jun
    Deng, Lisheng
    Li, Xing
    Feng, Yuheng
    Yan, Kai
    APPLIED THERMAL ENGINEERING, 2020, 169
  • [10] Experimental study on air cooling by spray in the upstream flow of a heat exchanger
    Tissot, J.
    Boulet, P.
    Labergue, A.
    Castanet, G.
    Trinquet, F.
    Fournaison, L.
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2012, 60 : 23 - 31