Fabrication of a new electrochemical imprinted sensor for determination of ketamine based on modified polytyramine/sol-gel/f-MWCNTs@AuNPs nanocomposite/pencil graphite electrode

被引:41
|
作者
Deiminiat, Behjat [1 ]
Rounaghi, Gholam Hossein [1 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Chem, Mashhad, Iran
关键词
Ketamine; Molecularly imprinted polymer; Polytyramine; Sol-gel; f-MWCNTs @AuNPs nanocomposite; MULTIWALLED CARBON NANOTUBES; SOL-GEL; GLASSY-CARBON; SIMULTANEOUS QUANTIFICATION; RECOGNITION ELEMENT; GOLD NANOPARTICLES; MASS-SPECTROMETRY; FUNCTIONAL LAYER; GLUCOSE-OXIDASE; CHROMATOGRAPHY;
D O I
10.1016/j.snb.2017.12.062
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper proposes a new strategy for measurement of ketamine through one-step electropolymerization of the molecularly imprinted polymer (MIP) composed of polytyramine (pty), sol-gel, functionalized-multiwall carbon nanotubes@gold nanoparticles (f-MWCNTs@AuNPs) nanocomposite and ketamine on a pencil graphite electrode (PGE) by cyclic voltammetric (CV) technique. F-MWCNTs@AuNPs nanocomposite was entrapped within the polymer network to enhance the electron transfer rate and sensitivityof the fabricated sensor. The f-MWCNTs@AuNPs nanocomposite was synthesized by the chemical reduction method and its structure characterized by X-ray diffraction (XRD), transmission electron microscopy (TEM) and energy dispersive X-ray analysis (EDX). The electrochemical behavior of the modified electrode was investigated using cyclic voltammetry, electrochemical impedance spectroscopy (EIS) and square wave voltammetry (SWV) techniques. Under the optimized experimental conditions, the calibration curve of the MIP electrode was plotted and two dynamic linear ranges from 1.0 to 50.0 nM and 50.0-1000.0 nM, with a limit of detection (LOD) of 0.7 nM were obtained for quantitative measurement of ketamine in solution. The obtained results show that the proposed sensor has an excellent stability, good reproducibility and repeatability, and high sensitivity and selectivity towards the ketamine molecules. Furthermore, the electrochemical imprinted sensor was successfully applied for determination of ketamine in biological samples with satisfactory results. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:133 / 141
页数:9
相关论文
共 50 条
  • [21] Fabrication of a New Electrochemical Sensor Based on Carbon Paste Electrode Modified by Silica gel/ MWCNTs for the Voltammetric Determination of Salicylic Acid in Tomato
    Rabie, E. M.
    Assaf, H. F.
    Shamroukh, A. A.
    Khodari, M.
    EGYPTIAN JOURNAL OF CHEMISTRY, 2019, 62 : 165 - 175
  • [22] An electrochemical sensor for the determination of tartrazine based on CHIT/GO/MWCNTs/AuNPs composite film modified glassy carbon electrode
    Rovina, Kobun
    Siddiquee, Shafiquzzaman
    Md Shaarani, Sharifudin
    DRUG AND CHEMICAL TOXICOLOGY, 2021, 44 (05) : 447 - 457
  • [23] Electrochemical sensor based on a carbon nanotube-modified imprinted sol-gel for selective and sensitive determination of 2-agonists
    Xu, Wei
    Liu, Ping
    Guo, Chunhui
    Dong, Chao
    Zhang, Xiuhua
    Wang, Shengfu
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1005 - 1011
  • [24] Electrochemical sensor for uric acid based on a molecularly imprinted polymer brush grafted to tetraethoxysilane derived sol-gel thin film graphite electrode
    Patel, A. K.
    Sharma, P. S.
    Prasad, B. B.
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (05): : 1545 - 1553
  • [25] A novel impedimetric sensor based on molecularly imprinted polypyrrole modified pencil graphite electrode for trace level determination of chlorpyrifos
    Uygun, Zihni Onur
    Dilgin, Yusuf
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 78 - 84
  • [26] Electrochemical Sensor for Detection of Trichlorfon Based on Molecularly Imprinted Sol–Gel Films Modified Glassy Carbon Electrode
    Weiqiang Gao
    Fuwei Wan
    Wei Ni
    Shaowei Wang
    Meng Zhang
    Jinghua Yu
    Journal of Inorganic and Organometallic Polymers and Materials, 2012, 22 : 37 - 41
  • [27] Voltammetric sensor for barbituric acid based on a sol-gel derivated molecularly imprinted polymer brush grafted to graphite electrode
    Patel, Amit Kumar
    Sharma, Piyush Sindhu
    Prasad, Bhim Bali
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2009, 371 (1-2) : 47 - 55
  • [28] Development of a new electrochemical imprinted sensor based on poly-pyrrole, sol-gel and multiwall carbon nanotubes for determination of tramadol
    Deiminiat, Behjat
    Rounaghi, Gholam Hossein
    Arbab-Zavar, Mohammad Hossein
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 651 - 659
  • [29] Zeolite-Modified Sol-Gel Electrode as an Electrochemical Sensor for Potentiometric Determination of Cesium Ions in Water Samples
    Arvand, Majid
    Moghimi, Majid
    Bagherinia, Mohammad A.
    ANALYTICAL LETTERS, 2009, 42 (02) : 393 - 408
  • [30] Electrochemical sensor for detection of europium based on poly-catechol and ion-imprinted sol-gel film modified screen-printed electrode
    Chen, Jin
    Bai, Huiping
    Xia, Jieren
    Li, Zixuan
    Liu, Peng
    Cao, Qiue
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 824 : 32 - 38