Porous silicon integrated Mach-Zehnder interferometer waveguide for biological and chemical sensing

被引:34
|
作者
Kim, Kyowon [1 ]
Murphy, Thomas E. [1 ]
机构
[1] Univ Maryland, Inst Res Elect & Appl Phys, College Pk, MD 20742 USA
来源
OPTICS EXPRESS | 2013年 / 21卷 / 17期
基金
美国国家科学基金会;
关键词
OPTICAL MICROCAVITY BIOSENSOR; REFRACTIVE-INDEX; SENSOR;
D O I
10.1364/OE.21.019488
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Optical waveguides comprised of nanoporous materials are uniquely suited for on-chip sensing applications, because they allow for a target chemical or analyte to directly infiltrate the optical material that comprises the core of the waveguide. We describe here the fabrication and characterization of nanoporous waveguides, and demonstrate their usefulness in measuring small changes in refractive index when exposed to a test analyte. We use a process of electrochemical etching and laser oxidation to produce channel waveguides and integrated on-chip Mach-Zehnder structures, and we compare the responsivity and interferometric stability of the integrated sensor to that of a fiber-based interferometer. We quantify the detection capability by selectively applying isopropanol to a 200 mu m length waveguide segment in one arm of the interferometer, which produces a phase shift of 9.7 pi. The integrated interferometer is shown to provide a more stable response in comparison to a comparable fiber-based implementation. (C) 2013 Optical Society of America
引用
收藏
页码:19488 / 19497
页数:10
相关论文
共 50 条
  • [31] Biosensor based on Single Mode Mach-Zehnder Interferometer Waveguide
    Boiragi, Indrajit
    Makkar, Roshan
    Chalapathi, K.
    2012 INTERNATIONAL CONFERENCE ON FIBER OPTICS AND PHOTONICS (PHOTONICS), 2012,
  • [33] Mach-Zehnder interferometer and the teleporter
    Ralph, TC
    PHYSICAL REVIEW A, 2000, 61 (04): : 4 - 443014
  • [34] MACH-ZEHNDER HETERODYNE INTERFEROMETER
    LAVAN, MJ
    VANDAMME, GE
    CADWALLENDER, WK
    OPTICAL ENGINEERING, 1976, 15 (05) : 464 - 466
  • [35] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    TANNER, LH
    HOWES, WL
    BUCHELE, DR
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (09): : 1583 - &
  • [36] ASTIGMATISM IN MACH-ZEHNDER INTERFEROMETER
    PROWSE, DB
    APPLIED OPTICS, 1967, 6 (04): : 773 - &
  • [37] THEORY OF THE MACH-ZEHNDER INTERFEROMETER
    BENNETT, FD
    KAHL, GD
    PHYSICAL REVIEW, 1952, 87 (01): : 234 - 234
  • [38] Gold and thiol surface functionalized integrated optical Mach-Zehnder interferometer for sensing purposes
    Busse, Stefan
    Käshammer, Josua
    Krämer, Stephan
    Mittler, Silvia
    Sensors and Actuators, B: Chemical, 1999, 60 (02): : 148 - 154
  • [39] A mesoscopic Mach-Zehnder interferometer
    Ji, Y
    Chung, Y
    Sprinzak, D
    Portier, F
    Heiblum, M
    Decoherence, Entanglement and Information Protection in Complex Quantum Systems, 2005, 189 : 601 - 604
  • [40] Ultralinear heterogeneously integrated ring-assisted Mach-Zehnder interferometer modulator on silicon
    Zhang, Chong
    Morton, Paul A.
    Khurgin, Jacob B.
    Peters, Jon D.
    Bowers, John E.
    OPTICA, 2016, 3 (12): : 1483 - 1488