Electrochemical Synthesis of a Polyaniline Network on a Poly(o-aminophenol) Modified Glassy Carbon Electrode and Its Use for the Simultaneous Determination of Ascorbic Acid and Uric Acid

被引:8
|
作者
Zhang, Lei [1 ]
Wang, Li-Lin [1 ]
机构
[1] Shanghai Normal Univ, Dept Chem, Coll Life & Environm Sci, Shanghai 200234, Peoples R China
关键词
CHEMICALLY-MODIFIED ELECTRODE; SELECTIVE VOLTAMMETRIC METHOD; ELECTROCATALYTIC OXIDATION; SULFONATED POLYANILINE; COVALENT MODIFICATION; GOLD NANOPARTICLES; PASTE ELECTRODES; O-AMINOPHENOL; FILM; DOPAMINE;
D O I
10.2116/analsci.28.1001
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A polyaniline (PAN) network structure was fabricated on a poly(o-aminophenol) (POAP) modified glassy carbon electrode (GCE) by using a three-step electrochemical deposition procedure, and applied to the electro-catalytic oxidation of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) have been employed to investigate the PAN network structure on a POAP modified GCE (PAN-OAP/GCE), which indicated the formation of a 3-dimensional (3D) non-periodic PAN network with good electrical contract and the maintenance of the electro-activity of PAN in neutral and even in alkaline media. Because of its different catalytic effect towards the electro-oxidation of AA and UA, the PAN-OAP/GCE could resolve the overlapped voltammetric response of AA and UA into two sharp and well-defined voltammetric peaks with both CV and differential pulse voltammetry (DPV), which could be applied for the selective and simultaneous determination of AA and UA in their binary mixture. Under the optimum conditions, the calibration curves for AA and UA were in the range of 2.5 - 6200 and 0.5 - 450 mu mol L-1 with correlation coefficients of 0.998 and 0.998, respectively. The detection limits (S/N = 3) are 1.4 and 0.3 mu mol L-1 for AA and UA, respectively. Besides good stability and reproducibility, the PAN-OAP/GCE also exhibited good sensitivity and selectivity. The proposed method has been applied to the simultaneous detection of AA and UA in human urine with satisfactory result.
引用
收藏
页码:1001 / 1007
页数:7
相关论文
共 50 条
  • [41] Electrocatalytic oxidation and simultaneous determination of uric acid and ascorbic acid on the gold nanoparticles-modified glassy carbon electrode
    Hu, Guangzhi
    Ma, Yonggen
    Guo, Yong
    Shao, Shijun
    ELECTROCHIMICA ACTA, 2008, 53 (22) : 6610 - 6615
  • [42] Simultaneous determination of dopamine, uric acid and ascorbic acid using a glassy carbon electrode modified with reduced graphene oxide
    Wang, Huiwen
    Ren, Fangfang
    Wang, Caiqin
    Yang, Beibei
    Bin, Duan
    Zhang, Ke
    Du, Yukou
    RSC ADVANCES, 2014, 4 (51) : 26895 - 26901
  • [43] A new sensor based on glassy carbon electrode modified with nanocomposite for simultaneous determination of acetaminophen, ascorbic acid and uric acid
    Afrasiabi, Mohammad
    Kianipour, Shokat
    Babaei, Ali
    Nasimi, Ali Asghar
    Shabanian, Meisam
    JOURNAL OF SAUDI CHEMICAL SOCIETY, 2016, 20 : S480 - S487
  • [44] Simultaneous determination of uric acid and ascorbic acid at the film of chitosan incorporating cetylpyridine bromide modified glassy carbon electrode
    Xiaomei Cao
    Yanhong Xu
    Liqiang Luo
    Yaping Ding
    Ying Zhang
    Journal of Solid State Electrochemistry, 2010, 14 : 829 - 834
  • [45] Selective Determination of Dopamine and Uric Acid at Poly(acid red 176) Modified Glassy Carbon Electrode in the Presence of Ascorbic Acid
    Li, Xiao-bo
    Xu, Guang-ri
    Hu, Rui-yuan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (02): : 1920 - 1927
  • [46] Simultaneous Determination of Dopamine, Ascorbic Acid and Uric Acid at Poly (Crystal Violet) Modified Carbon Paste Electrode
    Shankar, Sharath S.
    Swamy, Bahaddurghatta E. Kumara
    Chandra, Umesh
    Sherigara, Bailure S.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2011, 3 (05): : 462 - 477
  • [47] Poly-(Alizarin Red S)-Modified Glassy Carbon Electrode for Simultaneous Electrochemical Determination of Levodopa, Homovanillic Acid and Ascorbic Acid
    Hatefi-Mehrjardi, Abdolhamid
    Ghaemi, Nasrin
    Karimi, Mohammad Ali
    Ghasemi, Masoumeh
    Islami-Ramchahi, Somaieh
    ELECTROANALYSIS, 2014, 26 (11) : 2491 - 2500
  • [48] Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid
    Ren, W
    Luo, HQ
    Li, NB
    BIOSENSORS & BIOELECTRONICS, 2006, 21 (07): : 1086 - 1092
  • [49] Simultaneous determination of ascorbic acid, epinephrine and uric acid at over-oxidized poly(p-aminophenol) film modified electrode
    Kocak, Cagri Ceylan
    Dursun, Zekerya
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 694 : 94 - 103
  • [50] LaCoO3 Nanostructures Modified Glassy Carbon Electrode for Simultaneous Electrochemical Detection of Dopamine, Ascorbic Acid and Uric Acid
    Priyatharshni, S.
    Tamilselvan, A.
    Viswanathan, C.
    Ponpandian, N.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (04) : B152 - B158