Development and validation of an LC-MS/MS method for simultaneous quantification of co-administered trastuzumab and pertuzumab

被引:15
|
作者
Schokker, Sandor [1 ]
Fusetti, Fabrizia [2 ]
Bonardi, Francesco [2 ]
Molenaar, Remco J. [1 ]
Mathot, Ron A. A. [3 ]
van Laarhoven, Hanneke W. M. [1 ]
机构
[1] Univ Amsterdam, Amsterdam Univ Med Ctr, Canc Ctr Amsterdam CCA, Dept Med Oncol, NL-1105 AZ Amsterdam, Netherlands
[2] QPS Netherlands BV, Dept Business Dev Bioanal Europe, Groningen, Netherlands
[3] Univ Amsterdam, Amsterdam Univ Med Ctr, Dept Hosp Pharm, Amsterdam, Netherlands
关键词
Trastuzumab; pertuzumab; mAbs; monoclonal antibodies; lc-MS; pharmacokinetics; multiplex; validation; MONOCLONAL-ANTIBODIES; DEAMIDATION; SERUM;
D O I
10.1080/19420862.2020.1795492
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Given the increasing use of combination therapy with multiple monoclonal antibodies (mAbs), there is a clinical need for multiplexing assays. For the frequently co-administered anti-human epidermal growth factor receptor 2 (HER2) mAbs trastuzumab and pertuzumab, we developed a high-throughput and robust hybrid ligand-binding liquid chromatography-mass spectrometry (LC-MS)/MS quantitative assay. Nanomolar concentrations of trastuzumab and pertuzumab were determined in 10 mu L serum samples after extraction by affinity purification through protein A beads, followed by on-bead reduction, alkylation, and trypsin digestion. After electrospray ionization, quantification was obtained by multiple reaction monitoring LC-MS/MS using SILuMab as an internal standard. The method was validated according to the current guidelines from the US Food and Drug Administration and the European Medicines Agency. Assay linearity was established in the ranges 0.250-250 mu g/mL for trastuzumab and 0.500-500 mu g/mL for pertuzumab. The method was accurate and selective for the simultaneous determination of trastuzumab and pertuzumab in clinical samples, thereby overcoming the limitation of ligand binding assays that cannot quantify mAbs targeting the same receptor. Furthermore, this method requires a small blood volume, which reduces blood collection time and stress for patients. The assay robustness was verified in a clinical trial where trastuzumab and pertuzumab concentrations were determined in 670 serum samples. As we used commercially available reagents and standards, the described generic bioanalytical strategy can easily be adapted to multiplex quantifications of other mAb combinations in non-clinical and clinical samples.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Bioanalytical method development and validation for quantification of amivantamab in rat plasma by LC-MS/MS
    Gaddey, Pridhvi Krishna
    Sundararajan, Raja
    FUTURE JOURNAL OF PHARMACEUTICAL SCIENCES, 2024, 10 (01)
  • [22] Bioanalytical method development, validation and quantification of dorsomorphin in rat plasma by LC-MS/MS
    Karthikeyan, K.
    Mahat, Mahamad Yunnus A.
    Chandrasekaran, S.
    Gopal, K.
    Franklin, P. X.
    Sivakumar, Balasubramanian Jaganatha
    Singh, Gajendra
    Narayanan, Shridhar
    Gopalan, B.
    Khan, Ansar A.
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (08) : 1018 - 1026
  • [23] Development and validation of a LC-MS/MS method for the quantification of the regioisomers of dihydroxybutylether in human plasma
    Yuan, Bo
    Li, Li
    Fu, Yao
    Jin, Yi
    Guo, Lixin
    Xu, Haiyan
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 27 - 33
  • [24] Development and validation of an analytical method by LC-MS/MS for the quantification of estrogens in sewage sludge
    Gabet-Giraud, Virginie
    Miege, Cecile
    Herbreteau, Bernard
    Hernandez-Raquet, Guillermina
    Coquery, Marina
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (05) : 1841 - 1851
  • [25] Development and Validation of an Ultrasensitive LC-MS/MS Method for the Quantification of Melatonin in Human Saliva
    Demeuse, Justine J.
    Calaprice, Chiara
    Huyghebaert, Loreen C.
    Rechchad, Marwa
    Peeters, Stephanie
    Cavalier, Etienne
    Le Goff, Caroline
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2023, 34 (06) : 1056 - 1064
  • [26] Development and validation of an LC-MS/MS method for the quantification of artificial sweeteners in human matrices
    Greibe, Eva
    Leth-Moller, Magnus
    Stampe, Sofie
    Ovesen, Per
    Pedersen, Michael
    Hoffmann-Lucke, Elke
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (06)
  • [27] Development and validation of an LC-MS/MS method for the quantification of fascin proteins in human serum
    Li, Ke
    Zhang, Zhiling
    Wang, Kai
    Huang, Xin-Yun
    Lin, Zhongping
    BIOANALYSIS, 2022, 14 (16) : 1095 - 1109
  • [28] Development and validation of a LC-MS/MS method for the quantification of tenofovir and emtricitabine in seminal plasma
    Illamola, S. M.
    Valade, E.
    Hirt, D.
    Dulioust, E.
    Zheng, Y.
    Wolf, J. P.
    Treluyer, J. M.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1033 : 234 - 241
  • [29] Development and validation of an analytical method by LC-MS/MS for the quantification of estrogens in sewage sludge
    Virginie Gabet-Giraud
    Cécile Miege
    Bernard Herbreteau
    Guillermina Hernandez-Raquet
    Marina Coquery
    Analytical and Bioanalytical Chemistry, 2010, 396 : 1841 - 1851
  • [30] LC-MS/MS method using unbonded silica column and aqueous/methanol mobile phase for the simultaneous quantification of a drug candidate and co-administered metformin in rat plasma
    Discenza, Lorell
    D'Arienzo, Celia
    Olah, Timothy
    Jemal, Mohammed
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (19): : 1583 - 1589