Nonlinear identification of the total baroreflex arc: higher-order nonlinearity
被引:12
|
作者:
Moslehpour, Mohsen
论文数: 0引用数: 0
h-index: 0
机构:
Michigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USAMichigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
Moslehpour, Mohsen
[1
]
Kawada, Toru
论文数: 0引用数: 0
h-index: 0
机构:
Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Dynam, Osaka, JapanMichigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
Kawada, Toru
[2
]
Sunagawa, Kenji
论文数: 0引用数: 0
h-index: 0
机构:
Kyushu Univ, Grad Sch Med Sci, Dept Cardiovasc Med, Fukuoka, JapanMichigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
Sunagawa, Kenji
[3
]
Sugimachi, Masaru
论文数: 0引用数: 0
h-index: 0
机构:
Natl Cerebral & Cardiovasc Ctr, Dept Cardiovasc Dynam, Osaka, JapanMichigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
Sugimachi, Masaru
[2
]
Mukkamala, Ramakrishna
论文数: 0引用数: 0
h-index: 0
机构:
Michigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USAMichigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
Mukkamala, Ramakrishna
[1
]
机构:
[1] Michigan State Univ, Dept Elect & Comp Engn, 428 S Shaw Lane,Rm 2120,Engn Bldg, E Lansing, MI 48824 USA
arterial baroreflex;
Gaussian white noise;
system identification;
higher-order nonlinear model;
hypertension;
NEURAL ARC;
BARORECEPTOR REFLEX;
ARTERIAL-PRESSURE;
D O I:
10.1152/ajpregu.00101.2016
中图分类号:
Q4 [生理学];
学科分类号:
071003 ;
摘要:
The total baroreflex arc is the openloop system relating carotid sinus pressure (CSP) to arterial pressure (AP). The nonlinear dynamics of this system were recently characterized. First, Gaussian white noise CSP stimulation was employed in open-loop conditions in normotensive and hypertensive rats with sectioned vagal and aortic depressor nerves. Nonparametric system identification was then applied to measured CSP and AP to establish a second-order nonlinear Uryson model. The aim in this study was to assess the importance of higher-order nonlinear dynamics via development and evaluation of a third-order nonlinear model of the total arc using the same experimental data. Third-order Volterra and Uryson models were developed by employing nonparametric and parametric identification methods. The R-2 values between the AP predicted by the best third-order Volterra model and measured AP in response to Gaussian white noise CSP not utilized in developing the model were 0.69 +/- 0.03 and 0.70 +/- 0.03 for normotensive and hypertensive rats, respectively. The analogous R-2 values for the best third-order Uryson model were 0.71 +/- 0.03 and 0.73 +/- 0.03. These R-2 values were not statistically different from the corresponding values for the previously established second-order Uryson model, which were both 0.71 +/- 0.03 (P > 0.1). Furthermore, none of the third-order models predicted well-known nonlinear behaviors including thresholding and saturation better than the second-order Uryson model. Additional experiments suggested that the unexplained AP variance was partly due to higher brain center activity. In conclusion, the second-order Uryson model sufficed to represent the sympathetically mediated total arc under the employed experimental conditions.