A Study on the Development of a 1 MW Grid-Connected Photovoltaic Inverter System

被引:0
|
作者
Ahn, Kangsoon [1 ]
Oh, Yongseung [1 ]
Cho, Kyumin [2 ]
机构
[1] Willings Co Ltd, R&D Ctr, Yongin, South Korea
[2] Yuhan Univ, Dept I&C Engn, Bucheon, South Korea
关键词
grid-connected; PV inverter system; switching scheme; reference current polarity; dead-time; DEAD-TIME COMPENSATION; 3-LEVEL; DISTORTION;
D O I
10.1109/rtucon48111.2019.8982367
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a multi-central type 1 MW grid-connected photovoltaic inverter system, which consists of two 500 kW inverter panels that are composed of four 125 kW power stacks. In order to improve the reliability of large capacity inverter system, a new switching scheme is proposed. According to the proposed switching scheme, the possibility of arm-short is most minimized, and the dead time compensation is not needed. The detailed switching strategy of the proposed switching scheme and the major components design for a reliable commercial product are described. Also, the usefulness of the proposed inverter system has been verified by the experimental results include a temperature test.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A parameter identification model for the Photovoltaic grid-connected inverter
    Xu, Yan
    Jin, Weijia
    OPTIK, 2017, 142 : 23 - 32
  • [32] Research of Grid-Connected Photovoltaic Inverter Grid-Connected System Based on Dual Closed-Loop of Grid Voltage Vector Orientation
    Han, Qihang
    Li, Bo
    Li, Zixuan
    Ke, Qin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 5171 - 5176
  • [33] Study on three-phase photovoltaic grid-connected inverter system based on compositive control
    Li, Lian-Bing
    Zhao, Zhi-Guo
    Zhao, Zhao
    Wang, Hua-Jun
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (21): : 44 - 47
  • [34] Grid-Connected Photovoltaic System Based on a Cascaded H-Bridge Inverter
    Rezaei, Mohammad-Ali
    Iman-Eini, Hossein
    Farhangi, Shahrokh
    JOURNAL OF POWER ELECTRONICS, 2012, 12 (04) : 578 - 586
  • [35] Power Quality Investigation of Single Phase Grid-connected Inverter of Photovoltaic System
    Alawasa, Khaled M.
    Al-Odienat, Abdullah, I
    JOURNAL OF ENGINEERING AND TECHNOLOGICAL SCIENCES, 2019, 51 (05): : 597 - 614
  • [36] Modeling, control and analysis of cascaded inverter based grid-connected photovoltaic system
    Kumar, Nayan
    Saha, Tapas Kumar
    Dey, Jayati
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2016, 78 : 165 - 173
  • [37] Power Quality Characteristics of Residential Grid-Connected Inverter of Photovoltaic Solar System
    Alawasa, Khaled Mohammad
    Al-Odienat, Abdullah Ibrahim
    2017 IEEE 6TH INTERNATIONAL CONFERENCE ON RENEWABLE ENERGY RESEARCH AND APPLICATIONS (ICRERA), 2017, : 1097 - 1101
  • [38] High-frequency DC link inverter for grid-connected photovoltaic system
    Jung, Y
    Yu, GJ
    Choi, J
    Choi, J
    CONFERENCE RECORD OF THE TWENTY-NINTH IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE 2002, 2002, : 1410 - 1413
  • [39] Grid-connected photovoltaic generation system
    Department of Electrical Engineering, Yuan Ze University, Chung Li 32003, Taiwan
    IEEE Trans. Circuits Syst. Regul. Pap., 2008, 3 (953-964):
  • [40] Optimization of the master-slave inverter system for grid-connected photovoltaic plants
    Univ of Ghent, Gent, Belgium
    Energy Convers Manage, 12 (1239-1246):