Validity of three-dimensional computed tomography measurements for Le Fort I osteotomy

被引:12
|
作者
Gaia, B. F. [1 ]
Pinheiro, L. R. [1 ]
Umetsubo, O. S. [1 ]
Costa, F. F. [1 ]
Cavalcanti, M. G. P. [1 ]
机构
[1] Univ Sao Paulo, Sch Dent, BR-05508900 Sao Paulo, Brazil
关键词
three-dimensional; computed tomography; orthognathic surgery; ORTHOGNATHIC SURGERY; ANGULAR MEASUREMENTS; CLINICAL PROTOCOL; ACCURACY; COMPLICATIONS; RELIABILITY; SURFACE;
D O I
10.1016/j.ijom.2013.06.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study was to test the precision and accuracy of three-dimensional (3D) linear measurements for Le Fort I osteotomy, obtained from multi-slice computed tomography (MSCT) and cone beam computed tomography (CBCT) scans. The study population consisted of 11 dried skulls submitted to 64-row MSCT and CBCT scans. Three-dimensional reconstructed images (3D-CT) were generated, and linear measurements (n = 11) based on anatomical structures and landmarks of interest for Le Fort I osteotomy were performed independently by two oral and maxillofacial radiologists, twice each, using Vitrea software; this allows true 3D measurement on 3D-CT images. The results demonstrated no statistically significant differences between the inter-examiner and intra-examiner analyses, and physical and true 3D linear measurements using MSCT and CBCT images. Regarding examiner accuracy, no statistically significant differences were found for the comparisons among the physical and the MSCT and the CBCT linear measurements by either examiner. For examiners 1 and 2, the analysis intraexaminer correlation coefficient ranged from 0.87 to 0.96 and 0.82 to 0.98, respectively, using MSCT, and from 0.84 to 0.98 and 0.80 to 0.98, respectively, using CBCT, indicating almost perfect agreement for all analyses performed. 3D linear measurements obtained from MSCT and CBCT images were considered precise and accurate for Le Fort I osteotomy and thus accurate and helpful for Le Fort I osteotomy planning.
引用
收藏
页码:197 / 203
页数:7
相关论文
共 50 条
  • [31] Three-dimensional planning accuracy and follow-up of Le Fort I osteotomy in cleft lip/palate patients.
    Nys, Margaux
    van den Bempt, Maxim
    Shaheen, Eman
    Dormaar, Jakob Titiaan
    Politis, Constantinus
    JOURNAL OF STOMATOLOGY ORAL AND MAXILLOFACIAL SURGERY, 2023, 124 (04)
  • [32] Evaluation of stress distribution in critical anatomic regions following the Le Fort I osteotomy by three-dimensional finite element analysis
    Esen, Alparslan
    Dolanmaz, Elvan
    Dolanmaz, Dogan
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2019, 47 (03) : 431 - 437
  • [33] Accuracy of craniofacial measurements:: computed tomography and three-dimensional computed tomography compared with stereolithographic models
    Fruehwald, Julia
    Schicho, Kurt A.
    Figl, Michael
    Benesch, Thomas
    Watzinger, Franz
    Kainberger, Franz
    JOURNAL OF CRANIOFACIAL SURGERY, 2008, 19 (01) : 22 - 26
  • [34] Accuracy and reliability of linear measurements using 3-dimensional computed tomographic imaging software for Le Fort I Osteotomy: common mistakes
    Sabour, Siamak
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2014, 52 (09): : 872 - 872
  • [35] Three dimensional assessment of root changes after multi-segments Le Fort I osteotomy
    Alqahtani, Khalid Ayidh
    Shaheen, Eman
    Da Costa, Oliver
    Politis, Constantinus
    Jacobs, Reinhilde
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2024, 52 (12) : 1485 - 1490
  • [36] Assessment of nasal septum after Le Fort I osteotomy with computer tomography
    Moroi, Akinori
    Yoshizawa, Kunio
    Tsutsui, Takamitsu
    Saida, Yuriko
    Hotta, Asami
    Fukaya, Kenichi
    Hiraide, Ryota
    Takayama, Akihiro
    Tunoda, Tatsuya
    Saito, Yuuki
    Ueki, Koichiro
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (09) : 1187 - 1193
  • [37] Three-dimensional Analysis of Skeletal Stability in Cleft Lip and Palate Patients Undergoing Bimaxillary Surgery With Le Fort I Osteotomy and Intraoral Vertical Ramus Osteotomy
    Nguyen, Loi Phuoc
    Kim, Jun-Young
    Ha, Tae-Wook
    Nguyen, Chon Thanh Ho
    Park, Jin Hoo
    Jung, Young-Soo
    JOURNAL OF CRANIOFACIAL SURGERY, 2024, 35 (07) : 2088 - 2092
  • [38] Comparative three-dimensional maxillary stability assessment: Bioresorbable miniplate vs. titanium miniplate systems in Le Fort I osteotomy
    Takamatsu, Koki
    Shiogama, Sunao
    Ikehata, Yosuke
    Yasuda, Arisa
    Kurihara, Yuji
    Shirota, Tatsuo
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY MEDICINE AND PATHOLOGY, 2025, 37 (01)
  • [39] Three-Dimensional Nasal Alterations in Le Fort I Advancement: Linear Measurements, Angles, Nasal Indices, and Volume Differences
    Bettoni Rodrigues da Silva, Ana Maria
    Magri, Lais Valencise
    Osborne, Patrick Rocha
    Trivelatto, Alexandre Elias
    Sverzut, Cassio Edvard
    Moreira Rodrigues da Silva, Marco Antonio
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (04) : 1125 - 1130
  • [40] Three-dimensional analysis of maxillary stability after Le Fort I osteotomy using hydroxyapatite/poly-L-lactide plate
    Park, Jung-Hyun
    Kim, Minkyu
    Kim, Sang Yoon
    Jung, Hwi-Dong
    Jung, Young-Soo
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (04) : 421 - 426