Endobronchial ultrasound and positron emission tomography positive mediastinal lymph nodes

被引:53
|
作者
Plat, G
Pierard, P
Haller, A
Hutsebaut, J
Faber, J
Dusart, M
Eisendrath, P
Sculier, JP
Ninane, V
机构
[1] St Pierre Hosp, Chest Serv, B-1000 Brussels, Belgium
[2] Inst Jules Bordet, Dept Internal Med, B-1000 Brussels, Belgium
[3] Inst Jules Bordet, Dept Nucl Med, B-1000 Brussels, Belgium
[4] St Pierre Hosp, Dept Pathol, Brussels, Belgium
关键词
endobronchial ultrasound; lung cancer; mediastinal lymphadenopathy; positron emission tomography scan; staging; transbronchial needle aspiration;
D O I
10.1183/09031936.06.00139204
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Positron emission tomography with 18F-fluoro-2-deOXY-D-glucose (FDG-PET) is more accurate than computed tomography for staging of mediastinal (hilar) lymph nodes. In the case of positive findings, tissue sampling of lymph nodes is required. The diagnostic/staging yield of transbronchial needle aspiration (TBNA) following endobronchial ultrasound (EBUS) localisation was assessed in this particular clinical setting. The number of avoided surgical procedures was evaluated. All consecutive patients referred for staging and/or diagnosis of mediastinal FDG-PET positive lesions were included. Data were prospectively collected. TBNA sampling of lymph nodes was performed after EBUS localisation. If no diagnosis was reached, further surgical sampling or adequate follow-up was performed. From January 2003 to June 2004, 33 patients were included. The average number of TBNA samples per patient was 4.2 +/- 1.5. Cytological or histological diagnoses were obtained in 27 (82%) of the patients, of which 78% were obtained after previous EBUS localisation. In 25 (76%) of the 33 patients, surgical staging procedures were suppressed. In conclusion, transbronchial needle aspiration after endobronchial ultrasound localisation should be considered as a primary method of evaluation of lymph nodes positive by positron emission tomography with 18F-fluoro-2-deoxy-D-glucose, and may replace the majority of surgical mediastinal staging/diagnostic procedures.
引用
收藏
页码:276 / 281
页数:6
相关论文
共 50 条
  • [31] PET and endobronchial ultrasound. SUV value of mediastinal lymph nodes suspicious for malignancy
    Berto Botella, Juan
    Lopez Zalduendo, Esmeralda
    Gonzalez Gutierrez, Jessica
    Sanchez Salcedo, Pablo
    Rivera, Pilar
    Campo, Arantxa
    Belen Alcaide, Ana
    Pablo De Torres, Juan
    Martinez Urbistondo, Diego
    Zulueta, Javier
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46
  • [32] Effectiveness of the Benign and Malignant Diagnosis of Mediastinal and Hilar Lymph Nodes by Endobronchial Ultrasound Elastography
    Huang, Haidong
    Huang, Zhiang
    Wang, Qin
    Wang, Xinan
    Dong, Yuchao
    Zhang, Wei
    Zarogoulidis, Paul
    Man, Yan-Gao
    Schmidt, Wolfgang Hohenforst
    Bai, Chong
    JOURNAL OF CANCER, 2017, 8 (10): : 1843 - 1848
  • [33] Features predicting malignancy in mediastinal lymph nodes by endobronchial ultrasound in Indian setting: Is it different?
    Shah, Jeenam
    Goyal, Rajiv
    Nemani, Chetan
    Hibare, Kedar
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [34] Evaluation of a Novel Endobronchial Ultrasound-Guided Lymph Node Forceps in Enlarged Mediastinal Lymph Nodes
    Darwiche, Kaid
    Freitag, Lutz
    Nair, Arun
    Neumann, Christiane
    Karpf-Wissel, Ruediger
    Welter, Stefan
    Wohlschlaeger, Jeremias
    Theegarten, Dirk
    RESPIRATION, 2013, 86 (03) : 229 - 236
  • [35] Prediction of malignancy in mediastinal lymph nodes during endobronchial ultrasound: A comparative validation study
    Alici, Nur Safak
    Alici, Ibrahim Onur
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2023, 31 (01): : 63 - 68
  • [36] Endobronchial ultrasound-guided transbronchial needle aspiration of lymph nodes in the radiologically and positron emission tomography-normal mediastinum in patients with lung cancer
    Hetth, Felix J. F.
    Eberhardt, Ralf
    Krasnik, Mark
    Ernst, Armin
    CHEST, 2008, 133 (04) : 887 - 891
  • [37] Doppler ultrasound of mediastinal lymph nodes
    Ying, Michael
    JOURNAL OF THORACIC ONCOLOGY, 2008, 3 (04) : 325 - 326
  • [38] The value of endobronchial ultrasound-guided transbronchial needle aspiration, 18-fluorodeoxyglucose positron emission tomography/computed tomography, and ultrasonography imaging techniques in the diagnosis of mediastinal and/or hilar malignant, anthracotic, and other benign lymph nodes
    Korkmaz, Celalettin
    Demirbas, Soner
    Vatansev, Hulya
    MEDICINE, 2021, 100 (07) : E24728
  • [39] Transbronchial needle aspiration accurately diagnoses subcentimetre mediastinal and hilar lymph nodes detected by integrated positron emission tomography and computed tomography
    Hsu, Li-Han
    Ko, Jen-Sheng
    You, Dong-Ling
    Liu, Chia-Chuan
    Chu, Nei-Min
    RESPIROLOGY, 2007, 12 (06) : 848 - 855
  • [40] The use of 18F-FDG positron emission tomography to detect mediastinal lymph nodes in metastatic breast cancer
    Onal, Cem
    Findikcioglu, Alper
    Guler, Ozan Cem
    Reyhan, Mehmet
    BREAST, 2020, 54 : 197 - 202