A comparison of exercise type and intensity on the noninvasive assessment of skeletal muscle mitochondrial function using near-infrared spectroscopy

被引:50
|
作者
Ryan, Terence E. [1 ]
Brizendine, Jared T. [1 ]
McCully, Kevin K. [1 ]
机构
[1] Univ Georgia, Dept Kinesiol, Athens, GA 30602 USA
关键词
NIRS; mitochondrial capacity; oxidative metabolism; IN-VITRO MEASUREMENTS; CAPILLARY BLOOD-FLOW; HUMAN MOTOR UNITS; RAT MUSCLE; PHOSPHOCREATINE RECOVERY; ISOMETRIC CONTRACTIONS; ELECTRICAL-STIMULATION; OXIDATIVE-METABOLISM; OXYGEN-CONSUMPTION; KINETICS;
D O I
10.1152/japplphysiol.01043.2012
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
A comparison of exercise type and intensity on the noninvasive assessment of skeletal muscle mitochondrial function using near-infrared spectroscopy. J Appl Physiol 114: 230-237, 2013. First published November 15, 2012; doi:10.1152/japplphysiol.01043.2012.-Near-infrared spectroscopy (NIRS) can be used to measure muscle oxygen consumption (mVO(2)) using arterial occlusions. The recovery rate of mVO2 after exercise can provide an index of skeletal muscle mitochondrial function. The purpose of this study was to test the influence of exercise modality and intensity on NIRS measurements of mitochondrial function. Three experiments were performed. Thirty subjects (age: 18-27 yr) were tested. NIRS signals were corrected for blood volume changes. The recovery of mVO(2) after exercise was fit to a monoexponential curve, and a rate constant was calculated (directly related to mitochondrial function). No differences were found in NIRS rate constants for VOL and ES exercises (2.04 +/- 0.57 vs. 2.01 +/- 0.59 min(-1) for VOL and ES, respectively; P = 0.317). NIRS rate constants were independent of the contraction frequency for both VOL and ES (VOL: P = 0.166 and ES: P = 0.780). ES current intensity resulted in significant changes to the normalized time-tension integral (54 +/- 11, 82 +/- 7, and 100 +/- 0% for low, medium, and high currents, respectively; P < 0.001) but did not influence NIRS rate constants (2.02 +/- 0.54, 1.95 +/- 0.44, 2.02 +/- 0.46 min(-1) for low, medium, and high currents, respectively; P = 0.771). In summary, NIRS measurements of skeletal muscle mitochondrial function can be compared between VOL and ES exercises and were independent of the intensity of exercise. NIRS represents an important new technique that is practical for testing in research and clinical settings.
引用
收藏
页码:230 / 237
页数:8
相关论文
共 50 条
  • [31] Comparison of femoral blood gases and muscle near-infrared spectroscopy at exercise onset in humans
    MacDonald, MJ
    Tarnopolsky, MA
    Green, HJ
    Hughson, RL
    JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 687 - 693
  • [32] In Vivo Assessment of Mitochondrial Dysfunction in Clinical Populations Using Near-Infrared Spectroscopy
    Willingham, T. Bradley
    McCully, Kevin K.
    FRONTIERS IN PHYSIOLOGY, 2017, 8
  • [33] Noninvasive observation of skeletal muscle contraction using near-infrared time-resolved reflectance and diffusing-wave spectroscopy
    Belau, Markus
    Ninck, Markus
    Hering, Gernot
    Spinelli, Lorenzo
    Contini, Davide
    Torricelli, Alessandro
    Gisler, Thomas
    JOURNAL OF BIOMEDICAL OPTICS, 2010, 15 (05)
  • [34] Noninvasive estimation of skeletal muscle oxygen consumption rate and microvascular reactivity in chronic stroke survivors using near-infrared spectroscopy
    Hyngstrom, Allison S.
    Nguyen, Jennifer N.
    Gutterman, David D.
    Schmit, Brian D.
    Klevenow, Emilie A.
    Durand, Matthew J.
    JOURNAL OF APPLIED PHYSIOLOGY, 2024, 137 (01) : 23 - 31
  • [35] Recent developments in near-infrared spectroscopy (NIRS) for the assessment of local skeletal muscle microvascular function and capacity to utilise oxygen
    Jones, Siana
    Chiesa, Scott T.
    Chaturvedi, Nishi
    Hughes, Alun D.
    ARTERY RESEARCH, 2016, 16 : 25 - 33
  • [36] Sourcebook update: using near-infrared spectroscopy to assess skeletal muscle oxygen uptake
    Pelka, Edward Z.
    Davis, B. Ryan
    McDaniel, John
    ADVANCES IN PHYSIOLOGY EDUCATION, 2024, 48 (03) : 566 - 572
  • [38] SKELETAL-MUSCLE OXYGENATION DURING EXERCISE EVALUATED BY NEAR-INFRARED SPECTROSCOPY AND THE RELATION TO VENTILATORY PARAMETERS
    MIURA, T
    TAKEUCHI, T
    SATO, H
    TAKAHASHI, N
    TERAKADO, S
    FUJIEDA, Y
    IBUKIYAMA, C
    CIRCULATION, 1994, 90 (04) : 659 - 659
  • [39] DETERMINATION OF OXYGEN-CONSUMPTION IN MUSCLE DURING EXERCISE USING NEAR-INFRARED SPECTROSCOPY
    COLIER, WNJM
    MEEUWSEN, IBAE
    DEGENS, H
    OESEBURG, B
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1995, 39 : 151 - 155
  • [40] Methodological aspects of in vivo near-infrared spectroscopy in human skeletal muscle
    van Beekvelt, MCP
    van Engelen, BGM
    Wevers, RA
    Colier, WNJM
    NEUROLOGY, 2001, 56 (08) : A59 - A60