Effect of dose reduction on image quality and diagnostic performance in coronary computed tomography angiography

被引:8
|
作者
van der Bijl, Noortje [1 ]
Joemai, Raoul M. S. [1 ]
Mertens, Bart J. A. [2 ]
de Roos, Albert [1 ]
Veldkamp, Wouter J. H. [1 ]
Bax, Jeroen J. [3 ]
Schuijf, Joanne D. [3 ]
Geleijns, Jacob [1 ]
Kroft, Lucia J. M. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Radiol, NL-2333 ZA Leiden, Netherlands
[2] Leiden Univ, Med Ctr, Dept Med Stat & Bioinformat, NL-2333 ZC Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Cardiol, NL-2333 ZA Leiden, Netherlands
来源
关键词
Computed tomography angiography; Coronary arteries; Dose reduction; Diagnostic performance; CT ANGIOGRAPHY; RADIATION-EXPOSURE; PROTOCOLS;
D O I
10.1007/s10554-012-0096-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To evaluate the effect of radiation dose reduction on image quality and diagnostic accuracy of coronary computed tomography (CT) angiography. Coronary CT angiography studies of 40 patients with (n = 20) and without (n = 20) significant (a parts per thousand yen50 %) stenosis were included (26 male, 14 female, 57 +/- A 11 years). In addition to the original clinical reconstruction (100 % dose), simulated images were created that correspond to 50, 25 and 12.5 % of the original dose. Image quality and diagnostic performance in identifying significant stenosis were determined. Receiver-operator-characteristics analysis was used to assess diagnostic accuracy at different dose levels. The identification of patients with significant stenosis decreased consistently at doses of 50, 25 and 12.5 of the regular clinical acquisition (100 %). The effect was relatively weak at 50 % dose, and was strong at dose levels of 25 and 12.5 %. At lower doses a steady increase was observed for false negative findings. The number of coronary artery segments that were rated as diagnostic decreased gradually with dose, this was most prominent for smaller segments. The area-under-the-curve (AUC) was 0.90 (p = 0.4) at 50 % dose; accuracy decreased significantly with 25 % (AUC 0.70) and 12.5 % dose (AUC 0.60) (p < 0.0001), with underestimation of patients having significant stenosis. The clinical acquisition protocol for evaluation of coronary artery stenosis with CT angiography represents a good balance between image quality and patient dose. A potential for a modest (< 50 %) reduction of tube current might exist. However, more substantial reduction of tube current will reduce diagnostic performance of coronary CT angiography substantially.
引用
收藏
页码:453 / 461
页数:9
相关论文
共 50 条
  • [41] Diagnostic performance of coronary computed tomography angiography for coronary in-stent re-stenosis
    Kim, D.
    Cho, S. W.
    Kim, B. G.
    Kim, G. S.
    Byun, Y. S.
    Hwang, J.
    Kim, G.
    Doh, J. H.
    EUROPEAN HEART JOURNAL, 2024, 45
  • [42] Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography
    Domenico De Santis
    Tiziano Polidori
    Giuseppe Tremamunno
    Carlotta Rucci
    Giulia Piccinni
    Marta Zerunian
    Luca Pugliese
    Antonella Del Gaudio
    Gisella Guido
    Luca Barbato
    Andrea Laghi
    Damiano Caruso
    La radiologia medica, 2023, 128 : 434 - 444
  • [43] Computed Tomography Radiation Dose Reduction: Effect of Different Iterative Reconstruction Algorithms on Image Quality
    Willemink, Martin J.
    Takx, Richard A. P.
    de Jong, Pim A.
    Budde, Ricardo P. J.
    Bleys, Ronald L. A. W.
    Das, Marco
    Wildberger, Joachim E.
    Prokop, Mathias
    Buls, Nico
    de Mey, Johan
    Leiner, Tim
    Schilham, Arnold M. R.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2014, 38 (06) : 815 - 823
  • [44] Deep learning image reconstruction algorithm: impact on image quality in coronary computed tomography angiography
    De Santis, Domenico
    Polidori, Tiziano
    Tremamunno, Giuseppe
    Rucci, Carlotta
    Piccinni, Giulia
    Zerunian, Marta
    Pugliese, Luca
    Del Gaudio, Antonella
    Guido, Gisella
    Barbato, Luca
    Laghi, Andrea
    Caruso, Damiano
    RADIOLOGIA MEDICA, 2023, 128 (04): : 434 - 444
  • [45] Intraindividual evaluation of effects of image filter function on image quality in coronary computed tomography angiography
    Jin, Liang
    Gao, Pan
    Wang, Kun
    Li, Jianying
    Li, Ming
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [46] ADAPTIVE ITERATIVE DOSE REDUCTION IS ASSOCIATED WITH SIGNIFICANT REDUCTION IN TOTAL AND COMPUTED TOMOGRAPHY CORONARY ANGIOGRAPHY RADIATION EXPOSURE AND IMPROVED IMAGE QUALITY, COMPARED TO TRADITIONAL FILTERED BACKPROJECTION ON 320-MULTIDETECTOR COMPUTED TOMOGRAPHY
    Aslam, Anum
    Khokhar, Usman
    Cortegiano, Michael
    Poon, Michael
    Voros, Szilard
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 61 (10) : E923 - E923
  • [47] Multislice computed tomography coronary angiography: effect of experience on reader performance
    Pugliese, F.
    Hunink, M. G. M.
    Gruszczynska, K.
    Alberghina, F.
    Van Pelt, N.
    Malago', R.
    Meijboom, W. B.
    Mollet, N.
    Krestin, G. P.
    De Feyter, P. J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 720 - 720
  • [48] Radiation dose and image quality with dual source computer tomography coronary angiography
    Vazquez, M.
    Tardaguila, G.
    Delgado, C.
    Calatayud, J.
    Castellon, D.
    Vilar, M.
    Sanmartin, M.
    Tardaguila, F.
    EUROPEAN HEART JOURNAL, 2011, 32 : 525 - 525
  • [49] Diagnostic Performance of Low-Radiation-Dose Coronary Computed Tomography Angiography (vol 154, pg 413, 2011)
    von Ballmoos, M. W.
    Haring, B.
    Juillerat, P.
    Alkadhi, H.
    ANNALS OF INTERNAL MEDICINE, 2011, 154 (12) : 848 - 848
  • [50] Image quality in low-dose coronary computed tomography angiography with a new high-definition CT scanner
    Egle Kazakauskaite
    Lars Husmann
    Julia Stehli
    Tobias Fuchs
    Michael Fiechter
    Bernd Klaeser
    Jelena R. Ghadri
    Catherine Gebhard
    Oliver Gaemperli
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2013, 29 : 471 - 477