Enhanced spectral resolution of multiplex CARS microscopy with a spectral beam shaper

被引:1
|
作者
Choi, Dae Sik [1 ,2 ]
Yoon, Tae Oh [1 ]
Jeoung, Sae Chae [1 ]
机构
[1] Korea Res Inst Stand & Sci, Adv Technol Div, Taejon 305340, South Korea
[2] Korea Univ, Dept Phys, Sch Sci, Seoul 136701, South Korea
关键词
multiplex; CARs; supercontinuum; spectral beam shaper; spatial slit;
D O I
10.3938/jkps.53.590
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Enhancement of the spectral resolution in multiplex coherent anti-Stokes Raman scattering (CARS) microscopy is achieved by adapting a spectral beam shaper, which can vary the spectral bandwidth of the pump beam from 11 cm(-1) to 28 cm(-1). The feasibility of this way to attain high spectral resolution in multiplex CARS microscopy was tested oil polyvinyl thin films coated on slide glass and liquid 1,3,5-Triisopropylbenzene. The best spectral resolutions of about 24 cm(-1) and 18 cm(-1) for the C-H vibration mode of solid polymeric thin films and liquid 1,3,5-Triisopropylbenzene, respectively, show e a potential applicability of the multiplex configuration in CARS microscopy to solid polymer thin films and to liquid samples with rather complex vibrational spectra.
引用
收藏
页码:590 / 595
页数:6
相关论文
共 50 条
  • [31] Versatile silicon microwave photonic spectral shaper
    Guo, Xin
    Liu, Yang
    Yin, Tangman
    Morrison, Blair
    Pagani, Mattia
    Daulay, Okky
    Bogaerts, Wim
    Eggleton, Benjamin J.
    Casas-Bedoya, Alvaro
    Marpaung, David
    APL PHOTONICS, 2021, 6 (03)
  • [32] In situ quantitative measurement of concentration profiles in a microreactor with submicron resolution using multiplex CARS microscopy
    Schafer, Dawn
    Squier, Jeff A.
    van Maarseveen, Jan
    Bonn, Daniel
    Bonn, Mischa
    Mueller, Michiel
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (35) : 11592 - +
  • [33] In situ quantitative measurement of concentration profiles in a microreactor with submicron resolution using multiplex CARS microscopy
    Schafer, Dawn
    Squier, Jeff A.
    Van Maarseveen, Jan
    Bonn, Daniel
    Bonn, Mischa
    Müller, Michiel
    Journal of the American Chemical Society, 2008, 130 (35): : 11592 - 11593
  • [34] Enhanced spectral resolution via externally dispersed interferometry
    Edelstein, Jerry
    Erskine, David
    Sirk, Martin
    Vanderburg, Andrew
    Wishnow, Edward H.
    GROUND-BASED AND AIRBORNE INSTRUMENTATION FOR ASTRONOMY IV, 2012, 8446
  • [35] Multiplex imaging using white light laser and spectral confocal microscopy technology
    Rost, S.
    Anderson, K.
    Santoro, S.
    Koeppen, H.
    Chalouni, C. M.
    MOLECULAR BIOLOGY OF THE CELL, 2015, 26
  • [36] High resolution spectral self-interference fluorescence microscopy
    Swan, AK
    Moiseev, L
    Tong, YJ
    Lipoff, SH
    Karl, WC
    Goldberg, BB
    Ünlü, MS
    THREE-DIMENSIONAL AND MULTIDIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING IX, 2002, 4621 : 77 - 85
  • [37] Spectral counterstaining in luminescence-enhanced biological Raman microscopy
    Pelc, Radek
    Masek, Vlastimil
    Llopis-Torregrosa, Vicent
    Bour, Petr
    Wu, Tao
    CHEMICAL COMMUNICATIONS, 2019, 55 (57) : 8329 - 8332
  • [38] Signal shaper with a distributed delay: Spectral analysis and design
    Vyhlidal, Tomas
    Kucera, Vladimir
    Hromcik, Martin
    AUTOMATICA, 2013, 49 (11) : 3484 - 3489
  • [39] Spectral imaging and microscopy
    Levenson, RM
    Hoyt, CC
    AMERICAN LABORATORY, 2000, 32 (22) : 26 - +
  • [40] ENHANCED SPECTRAL RESOLUTION FFT FOR STEP-LIKE SIGNALS
    CORMACK, GD
    BLAIR, DA
    MCMULLIN, JN
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (01) : 34 - 36