Structure-Induced Method for Circular Cross-Sectional Nanochannel Fabrication

被引:16
|
作者
Yin, Zhifu [1 ]
Wang, Weihang [2 ]
机构
[1] Jilin Univ, Sch Mech Sci & Engn, Changchun 130012, Jilin, Peoples R China
[2] Yongkang Elect Power Co Ltd, Yongkang 321301, Peoples R China
基金
中国国家自然科学基金;
关键词
PDMS Nanochannel; Spin-Coating; Numerical Simulation; Structure-Induced Method; TRANSPORT;
D O I
10.1166/jnn.2019.16566
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Nanochannels are key elements in building nano-systems for many applications, such as ion transportation, single molecule manipulation, and protein analysis. Commercially manufacturing of nanosystems lies in the development of a low-cost and concise method for nanochannels fabrication. In the present work, a novel PDMS nanochannels fabrication method was proposed based on PDMS spin-coating on a structure-induced wafer. All the influencing parameters which can affect the shape and size of PDMS nanochannels were optimized by proposed simulation method. The comparison between experiments and simulation showed good agreement and confirmed the developed simulation method. By the optimized conditions, 64 nm wide and 37 nm deep PDMS nanochannels can be fabricated.
引用
收藏
页码:5750 / 5754
页数:5
相关论文
共 50 条
  • [31] THE VIBROSCOPIC METHOD FOR DETERMINATION OF FIBER CROSS-SECTIONAL AREA
    MONTGOMERY, DJ
    MILLOWAY, WT
    TEXTILE RESEARCH JOURNAL, 1952, 22 (11) : 729 - 735
  • [32] GLUCOCORTICOID-INDUCED OSTEOPOROSIS - A CROSS-SECTIONAL STUDY
    BRANDLI, DW
    GOLDE, G
    GREENWALD, M
    SILVERMAN, SL
    STEROIDS, 1991, 56 (10) : 518 - 523
  • [33] The Method of Purging Applied to Repeated Cross-Sectional Data
    Manfred Te Grotenhuis
    Rob Eisinga
    Peer Scheepers
    Quality and Quantity, 2004, 38 (1) : 1 - 16
  • [34] ULTRASONOGRAPHY AS A METHOD TO DETERMINE TENDON CROSS-SECTIONAL AREA
    GILLIS, C
    SHARKEY, N
    STOVER, SM
    POOL, RR
    MEAGHER, DM
    WILLITS, N
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1995, 56 (10) : 1270 - 1274
  • [35] Conductance Method for the Measurement of Cross-Sectional Areas of the Aorta
    L. Kornet
    J. R. C. Jansen
    E. J. Gussenhoven
    M. R. Hardeman
    Arnold P. G. Hoeks
    A. Versprille
    Annals of Biomedical Engineering, 1999, 27 : 141 - 150
  • [36] New preparation method for cross-sectional TEM specimens
    Aachen Univ of Technology, Aachen, Germany
    Mater Charact, 4-5 (365-369):
  • [37] A novel method of yarn cross-sectional area calculation
    Narkhedkar, Ramesh
    RESEARCH JOURNAL OF TEXTILE AND APPAREL, 2016, 20 (01) : 61 - 70
  • [38] A new preparation method for cross-sectional TEM specimens
    Klaar, HJ
    Hsu, FY
    MATERIALS CHARACTERIZATION, 1996, 36 (4-5) : 365 - 369
  • [39] A cross-sectional shape initial design method for automotive frame structure using genetic algorithms
    Yoshimura, Masataka
    Nishiwaki, Shinji
    Izui, Kazuhiro
    Nippon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, 2004, 70 (01): : 235 - 242
  • [40] Circular saw misuse is related to upper limb injuries: a cross-sectional study
    Sabongi, Rodrigo Guerra
    Erazo, Jaime Piccaro
    de Moraes, Vinicius Ynoe
    Fernandes, Carlos Henrique
    Gomes dos Santos, Joao Baptista
    Faloppa, Flavio
    Belloti, Joao Carlos
    CLINICS, 2019, 74