Performance of insulation systems for low voltage APFC panels during temperature rise test at elevated ambient temperatures

被引:0
|
作者
Vaidhyanathan, V. [1 ]
Shanker, T. Bhavani [1 ]
Rao, G. Govinda [1 ]
Nagamani, H. N. [1 ]
机构
[1] Cent Power Res Inst, Bangalore 560012, Karnataka, India
来源
2012 IEEE 10TH INTERNATIONAL CONFERENCE ON THE PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS (ICPADM) | 2012年
关键词
Power factor; APFC panels; Capacitor bank; Reactor; temperature rise;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Application of Automatic Power Factor Correction panels (APFC) in electrical distribution network is gaining importance due to the advantages of APFC panels over fixed capacitor banks, like, ability to maintain the target power factor with varying load and hence improve efficiency of the system and consequently reduce distribution losses. The desired performance of the APFC panels can be efficiently achieved with appropriate design, material, construction and application. Temperature rise test is one of the important tests to assess the thermal performance of constituent components of APFC panels. Rise in temperature and hence performance of materials and components is influenced by the ambient temperature which may be as high as 50 degrees C. The paper deals with the performance of APFC panels at elevated ambient temperatures. Temperature rise measured at capacitor banks, reactors, switching components and MCCBs employed in APFC panels are discussed. The information would help in arriving at limits for temperature rise for components employed in 3 phase low voltage APFC panels.
引用
收藏
页数:4
相关论文
共 29 条
  • [11] Concentration levels of selected hormones in judokas and the extent of their changes during a special performance test at different ambient temperatures
    Palka, Tomasz
    Rydzik, Lukasz
    Tota, Lukasz
    Koteja, Piotr
    Ambrozy, Tadeusz
    Mucha, Dariusz
    Szpotowicz-Czech, Barbara
    Lech, Grzegorz
    Javdaneh, Norollah
    Czarny, Wojciech
    BMC SPORTS SCIENCE MEDICINE AND REHABILITATION, 2023, 15 (01)
  • [12] Concentration levels of selected hormones in judokas and the extent of their changes during a special performance test at different ambient temperatures
    Tomasz Pałka
    Łukasz Rydzik
    Łukasz Tota
    Piotr Koteja
    Tadeusz Ambroży
    Dariusz Mucha
    Barbara Szpotowicz-Czech
    Grzegorz Lech
    Norollah Javdaneh
    Wojciech Czarny
    BMC Sports Science, Medicine and Rehabilitation, 15
  • [13] Models for predicting the test medium temperature during hydrotesting pipe segments based on measured ambient and pipe wall temperatures
    Botros, K. K.
    Crowe, J.
    Liu, V
    Lu, J.
    JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2021, 92
  • [14] Problems of the starting and operating of hydraulic components and systems in low ambient temperature Part III Methods of determining parameters for correct start-ups of hydraulic components and systems in low ambient temperatures
    Jasinski, Ryszard
    POLISH MARITIME RESEARCH, 2009, 16 (04) : 22 - 30
  • [15] Medium factors of electrical insulation systems in high temperature superconducting power apparatus with coil structure for equivalent ac withstand voltage test at room temperature
    Hara, M
    Kurihara, T
    Nakano, R
    Suehiro, J
    CRYOGENICS, 2005, 45 (10-11) : 705 - 717
  • [16] Can lesion size during radiofrequency ablation be predicted by the temperature rise to a low power test pulse in vitro?
    Petersen, HH
    Svendsen, JH
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2003, 26 (08): : 1653 - 1659
  • [17] Exposure of workers to extremely low frequency magnetic fields during the temperature-rise test of electrotechnical equipment
    Halevidis, C. D.
    Koustellis, J. D.
    Polykrati, A. D.
    Bourkas, P. D.
    MEASUREMENT, 2012, 45 (08) : 1960 - 1965
  • [18] Problems of the starting and operating of hydraulic components and systems in low ambient temperature Part II Determining the clearance between cooperating elements during the hydraulic components start-up in extremely low ambient temperatures on the grounds of experimental research
    Jasinski, Ryszard
    POLISH MARITIME RESEARCH, 2009, 16 (01) : 61 - 72
  • [19] Thermal performance and moisture accumulation of fibrous mechanical pipe insulation systems operating at below-ambient temperature in wet conditions with moisture ingress
    School of Mechanical and Aerospace Engineering, Oklahoma State University, Stillwater
    OK
    74078, United States
    不详
    Sc. Tech. Built Environ., 6 (862-875):
  • [20] Thermal performance and moisture accumulation of fibrous mechanical pipe insulation systems operating at below-ambient temperature in wet conditions with moisture ingress
    Zhu, Weiwei
    Cai, Shanshan
    Cremaschi, Lorenzo
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2015, 21 (06) : 862 - 875