Microstructural characterization and comparative evaluation of physical, mechanical and biological properties of three ceramics for metal-ceramic restorations

被引:32
|
作者
Kontonasaki, Eleana
Kantiranis, Nikolaos [2 ]
Papadopoulou, Lambrini [2 ]
Chatzistavrou, Xanthippi [3 ]
Kavouras, Panagiotis [3 ]
Zorba, Triantafillia [3 ]
Sivropoulou, Afroditi [4 ]
Chrissafis, Konstantinos [3 ]
Paraskevopoulos, Konstantinos M. [3 ]
Koidis, Petros T. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Dent, Dept Fixed Prosthesis & Implant Prosthodont, GR-54124 Thessaloniki, Greece
[2] Aristotle Univ Thessaloniki, Dept Geol, GR-54124 Thessaloniki, Greece
[3] Aristotle Univ Thessaloniki, Dept Phys, GR-54124 Thessaloniki, Greece
[4] Aristotle Univ Thessaloniki, Dept Biol, GR-54124 Thessaloniki, Greece
关键词
dental ceramics; metal-ceramic restorations; leucite; fluorapatite; fracture toughness; X-ray diffraction; scanning microscopy; Fourier transform infrared; spectroscopy; thermal analysis; bio compatibility;
D O I
10.1016/j.dental.2008.03.002
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives. A wide variety of dental ceramics compositions have been introduced in dental clinical practice in order to combine desired aesthetics with superior mechanical performance. The aim of the present study was to investigate the microstructural changes in three dental ceramics after their sintering according to manufacturers' instructions and to comparatively evaluate some of their physical, mechanical and biological properties. Methods. The analysis of the phases present in each material before and after sintering was performed with scanning electron microscopy (SEM), Fourier transform infrared spectroscopy (FTIR) and X-ray diffraction analysis (XRD). The thermal properties of ceramic specimens were evaluated with differential thermal and thermogravimetric analysis (TG-DTA). The mechanical properties evaluated were fracture toughness, Young's modulus and microhardness with the Vickers indentation method. MTT assay was used for cell proliferation assessment. One-way analysis of variance (ANOVA) with Bonferroni multiple comparisons tests was used to determine statistically significant differences (significance level of p < 0.05). Results. Results showed a remarkable variation among the three ceramic compositions of leucite content in the starting unheated ceramic powders ranging between 14 and 32 wt.% and in the respective sintered powders ranging between 15 and 41 wt.% The low fusing glass-ceramic and the high fusing leucite-based ceramic presented significantly higher fracture toughness (p < 0.001) and microhardness and lower modulus of elasticity (p < 0.05) compared to the low fusing feldspathic ceramic. The three ceramics were almost equivalent concerning their in vitro biological behavior. Significance. Variations in crystal structure, distribution and composition are related to differences concerning mechanical properties of dental ceramics. (C) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:1362 / 1373
页数:12
相关论文
共 50 条
  • [41] Mechanical Properties of Five Esthetic Ceramic Materials Used for Monolithic Restorations: A Comparative In Vitro Study
    Almohammed, Saleh N.
    Alshorman, Belal
    Abu-Naba'a, Layla A.
    CERAMICS-SWITZERLAND, 2023, 6 (02): : 1031 - 1049
  • [42] Comparison of mechanical properties of three machinable ceramics with an experimental fluorophlogopite glass ceramic
    Leung, Brian T. W.
    Tsoi, James K. H.
    Matinlinna, Jukka P.
    Pow, Edmond H. N.
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (03): : 440 - 446
  • [43] Clinical Evaluation of Corrosion Resistance, Ion Release, and Biocompatibility of CoCr Alloy for Metal-Ceramic Restorations Produced by CAD/CAM Technologies
    Tomova, Zlatina
    Vlahova, Angelina
    Zlatev, Stefan
    Stoeva, Ilyana
    Tomov, Desislav
    Davcheva, Delyana
    Hadzhigaev, Viktor
    DENTISTRY JOURNAL, 2023, 11 (07)
  • [44] Characterization of dental metal-ceramic interfaces immersed in artificial saliva after substructural mechanical metallization with titanium
    Souza, Julio C. M.
    Nascimento, Rubens M.
    Martinelli, Antonio E.
    SURFACE & COATINGS TECHNOLOGY, 2010, 205 (03): : 787 - 792
  • [45] Microstructural Characterization, Mechanical, Physical and Thermal Properties of a Diesel Particulate Filter
    Nurcan Calis Acikbas
    Yigit Ture
    Emre Gurlek
    Selcuk Ozcan
    Seref Soylu
    Gokhan Acikbas
    Turker Gudu
    Arabian Journal for Science and Engineering, 2018, 43 : 1383 - 1394
  • [46] Microstructural Characterization, Mechanical, Physical and Thermal Properties of a Diesel Particulate Filter
    Acikbas, Nurcan Calis
    Ture, Yigit
    Gurlek, Emre
    Ozcan, Selcuk
    Soylu, Seref
    Acikbas, Gokhan
    Gudu, Turker
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2018, 43 (03) : 1383 - 1394
  • [47] Fracture Resistance and Failure Mode of Monolithic Zirconia, Veneered Zirconia, and Metal-Ceramic Full-Coverage Restorations: A Comparative In Vitro Study
    Almohammed, Saleh N.
    Dourado, Annalita M.
    Al Quran, Firas A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (01) : 80 - 91
  • [48] COMPARATIVE EVALUATION OF THE CORROSION RESISTANCE OF SOME CO-CR ALLOYS USED IN METAL-CERAMIC TECHNOLOGY
    Laurentiu, Dragus
    Mihaela, Buciumeanu
    Valentin, Amortila
    Monica, Comaneanu Raluca
    Elena, Ungureanu
    Violeta, Hancu
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2022, 14 (02): : 140 - 152
  • [49] In vitro evaluation of marginal microleakage and adaptation of metal-ceramic crowns luted with three types of cements.
    Motta, B
    Pegoraro, LF
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B183 - B183
  • [50] In vitro evaluation of marginal microleakage and adaptation of metal-ceramic crowns luted with three types of cements.
    Motta, B
    Pegoraro, LK
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B207 - B207