Capsule Endoscopy, Magnetic Resonance Enterography, and Small Bowel Ultrasound for Evaluation of Postoperative Recurrence in Crohn's Disease: Systematic Review and Meta-Analysis

被引:51
|
作者
Yung, Diana E. [1 ]
Har-Noy, Ofir [2 ,3 ]
Tham, Yuen Sau [1 ]
Ben-Horin, Shomron [2 ,3 ]
Eliakim, Rami [2 ,3 ]
Koulaouzidis, Anastasios [1 ]
Kopylov, Uri [2 ,3 ]
机构
[1] Royal Infirm Edinburgh NHS Trust, Ctr Liver & Digest Disorders, Edinburgh, Midlothian, Scotland
[2] Sheba Med Ctr, Dept Gastroenterol, 1 Emek HaEla St, Ramat Gan, Israel
[3] Tel Aviv Univ, Sackler Sch Med, Tel Aviv, Israel
关键词
capsule endoscopy; Crohn's disease; magnetic resonance enterography; meta-analysis; postoperative recurrence; small bowel ultrasound; systematic review; INTESTINE CONTRAST ULTRASONOGRAPHY; HIGH-RISK PATIENTS; POSTSURGICAL RECURRENCE; ILEOCOLIC RESECTION; SURGICAL RECURRENCE; NATURAL-HISTORY; MR ENTEROCLYSIS; DIAGNOSIS; SURGERY; SONOGRAPHY;
D O I
10.1093/ibd/izx027
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background: Anastomotic recurrence is frequent in patients with Crohn's disease (CD) following ileocecal resection. The degree of endoscopic recurrence, quantified by the Rutgeerts score (RS), is correlated with the risk of clinical and surgical recurrence. Noninvasive modalities such as capsule endoscopy (CE), magnetic resonance enterography (MRE), and intestinal ultrasound (US) may yield similar information without the need for ileocolonoscopy (IC). The aim of our meta-analysis was to evaluate the accuracy of those modalities for detection of endoscopic recurrence in postoperative CD patients. Methods: We performed a systematic literature search for studies comparing the accuracy of CE, MRE, and US with IC for detection of postoperative recurrence in CD. We calculated pooled diagnostic sensitivity, specificity, diagnostic odds ratio (DOR), and area under the curve (AUC) for each comparison. Results: A total of 135 studies were retrieved; 14 studies were eligible for analysis. For CE, the pooled sensitivity was 100% (95% CI, 91%-100%), specificity was 69% (95% CI, 52%-83%), DOR was 30.8 (95% CI, 6.9-138), and AUC was 0.94. MRE had pooled sensitivity of 97% (95% CI, 89%-100%), specificity of 84% (95% CI, 62%-96%), DOR of 129.5 (95% CI, 16.4-1024.7), and AUC of 0.98. US had pooled sensitivity of 89% (95% CI, 85%-92%), specificity of 86% (95% CI, 78%-93%), DOR of 42.3 (95% CI, 18.6-96.0), and AUC 0.93. Conclusions: CE, MRE, and US provide accurate assessment of postoperative endoscopic recurrence in CD. These modalities should gain wider use for detection of postoperative recurrence; the prognostic value of those diagnostic findings merits evaluation in further prospective studies.
引用
收藏
页码:93 / 100
页数:8
相关论文
共 50 条
  • [31] Diagnostic Accuracy of Fecal Calprotectin for the Detection of Small Bowel Crohn's Disease through Capsule Endoscopy: An Updated Meta-Analysis and Systematic Review
    Jung, Eun Suk
    Lee, Sang Pyo
    Kae, Sea Hyub
    Kim, Jung Han
    Kim, Hyeong Su
    Jang, Hyun Joo
    GUT AND LIVER, 2021, 15 (05) : 732 - 741
  • [32] Systematic review with meta-analysis: magnetic resonance enterography signs for the detection of inflammation and intestinal damage in Crohn's disease
    Church, P. C.
    Turner, D.
    Feldman, B. M.
    Walters, T. D.
    Greer, M. -L.
    Amitai, M. M.
    Griffiths, A. M.
    ALIMENTARY PHARMACOLOGY & THERAPEUTICS, 2015, 41 (02) : 153 - 166
  • [33] Biologics for the prevention of postoperative Crohn's disease recurrence: A systematic review and meta-analysis
    Zhao, Ye
    Ma, Teng
    Chen, Yan-Fang
    He, Xiao-Yan
    Ren, Li-Hua
    Chen, Jian
    Fang, Lin
    Su, Jie-Wen
    Zhang, Hong-Jie
    Shi, Rui-Hua
    CLINICS AND RESEARCH IN HEPATOLOGY AND GASTROENTEROLOGY, 2015, 39 (05) : 637 - 649
  • [34] Postoperative recurrence of Crohn's disease: correlation between endoscopy and bowel ultrasound
    Yebra Carmona, J.
    Suarez Ferrer, C.
    Poza Cordon, J.
    Rueda Garcia, J. L.
    Lucas Ramos, J.
    Andaluz Garcia, I.
    Martin Arranz, E.
    Gomez Senent, S.
    Martin Arranz, M. D.
    Mora Sanz, P.
    JOURNAL OF CROHNS & COLITIS, 2019, 13 : S175 - S175
  • [35] Capsule endoscopy for small-bowel evaluation in Crohn's disease
    Doherty, Glen A.
    Moss, Alan C.
    Cheifetz, Adam S.
    GASTROINTESTINAL ENDOSCOPY, 2011, 74 (01) : 167 - 175
  • [36] Colon Capsule Endoscopy for Small Bowel Evaluation in Crohn's Disease
    Suarez, Begona Gonzalez
    de Miguel, Cristina Rodriguez
    Romero, Cristina
    Ordas, Ingrid
    Jauregui-Amezaga, Aranzazu
    Ricart, Elena
    Ramirez, Anna
    Gallego, Marta
    Fernandez-Esparrach, Gloria
    Gines, Angels
    Llach, Josep
    Panes, Julian
    GASTROENTEROLOGY, 2015, 148 (04) : S827 - S827
  • [37] Magnetic Resonance Enterography, Small-Bowel Contrast Ultrasonography and Capsule Endoscopy to Evaluate Small Bowel in Pediatric Crohn's Disease: A Prospective, Blinded, Comparison Trial
    Aloi, Marina
    Casciani, Emanuele
    Di Nardo, Giovanni
    Romano, Giuseppina
    Civitelli, Fortunata
    Oliva, Salvatore
    Viola, Franca
    Gualdi, Gianfranco
    Cucchiara, Salvatore
    GASTROENTEROLOGY, 2013, 144 (05) : S531 - S531
  • [38] Comparison of Diagnostic Performance of Ultrasonography and Magnetic Resonance Enterography in the Assessment of Active Bowel Lesions in Patients with Crohn's Disease: A Systematic Review and Meta-Analysis
    Lee, Da In
    You, Myung-Won
    Park, So Hyun
    Seo, Mirinae
    Park, Seong Jin
    DIAGNOSTICS, 2022, 12 (08)
  • [39] Systematic review and meta-analysis: is bowel preparation still necessary in small bowel capsule endoscopy?
    Yung, Diana E.
    Rondonotti, Emanuele
    Sykes, Catherine
    Pennazio, Marco
    Plevris, John N.
    Koulaouzidis, Anastastios
    EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2017, 11 (10) : 979 - 993
  • [40] Small bowel capsule endoscopy and treat-to-target in Crohn's disease: A systematic review
    Catherine Le Berre
    Caroline Trang-Poisson
    Arnaud Bourreille
    World Journal of Gastroenterology, 2019, 25 (31) : 4534 - 4554