Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA

被引:26
|
作者
Krishnam, M. S. [1 ]
Tomasian, A. [1 ]
Lohan, D. G. [1 ]
Tran, L. [1 ]
Finn, J. P. [1 ]
Ruehm, S. G. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
关键词
D O I
10.1016/j.crad.2008.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the effectiveness of low-dose, contrast-enhanced, time-resolved, three-dimensional (3D) magnetic resonance (MR) angiography (TR-MRA) in the assessment of various cardiac and vascular diseases, and to compare the results with high-resolution contrast-enhanced MRA (CE-MRA). MATERIALS AND METHODS: Thirty consecutive patients underwent contrast-enhanced 3D TR-MRA and high spatial resolution 3D CE-MRA for evaluation of cardiac and thoracic vascular diseases at 1.5 T, and neurovascular, abdominal and peripheral vascular diseases at 3 T. Gadolinium-based contrast medium was administered at a constant dose of 5 ml for TR-MRA, and 20 ml (lower extremity 30 ml) for CE-MRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = non-diagnostic), artefacts and findings on both datasets. Interobserver variability was tested with kappa coefficient. RESULTS: The overall image quality for TR-MRA was in the diagnostic range (median 0, range 0-1; k = 0.74). Readers demonstrated important additional dynamic information on TR-MRA in 28 of 30 patients (k = 0.84). Confident evaluation of organ perfusion (n = 23), arteriovenous malformation/fistula flow patterns (n = 7), exclusion of intra-cardiac shunts (n = 6), and assessment of stent and conduit patency (n = 5) were performed by both readers using TR-MRA. Readers demonstrated fine vascular details with higher confidence in 10 patients on CE-MRA. Using CE-MRA, Reader 1 and 2 depicted anatomical details in 6 and 5 patients, respectively, only on CE-MRA. CONCLUSION: Low-dose TR-MRA yields rapid and important functional and anatomical information in patients with cardiac and vascular diseases. Due to limited spatial resolution, TR-MRA is inferior to CE-MRA in demonstrating fine vascular details. (C) 2008 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:744 / 755
页数:12
相关论文
共 50 条
  • [41] Contrast-enhanced time-resolved MR angiography of spinal vascular malformations
    Mascalchi, M
    Cosottini, M
    Ferrito, G
    Quilici, N
    Bartolozzi, C
    Villari, N
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (03) : 341 - 345
  • [42] Contrast-enhanced 3D MR angiography of moyamoya disease: Comparison with conventional 3D time-of-flight MR angiography
    Yoon, H
    Shin, H
    Na, D
    Cho, Y
    Han, BK
    RADIOLOGY, 2000, 217 : 429 - 429
  • [43] Unmasking pedal arteries in patients with critical ischemia using time-resolved contrast-enhanced 3D MRA
    Langer, Stephan
    Kramer, Nils
    Mommertz, Gottfried
    Koeppel, Thomas A.
    Jacobs, Michael J.
    Wazirie, Noor A.
    Ocklenburg, Christina
    Spuntrup, Elmar
    JOURNAL OF VASCULAR SURGERY, 2009, 49 (05) : 1196 - 1202
  • [44] Contrast-enhanced 3D MR angiography in the chest, abdomen and lower extremities
    Rühm, SG
    Debatin, JF
    RADIOLOGE, 1999, 39 (02): : 100 - 109
  • [45] Head and neck paragangliomas: Value of contrast-enhanced 3D MR angiography
    Neves, F.
    Huwart, L.
    Jourdan, G.
    Reizine, D.
    Herman, P.
    Vicaut, E.
    Guichard, J. P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (05) : 883 - 889
  • [46] The clinical utility of contrast-enhanced 3D MR angiography for cerebrovascular disease
    Okumura, A
    Araki, Y
    Nishimura, Y
    Iwama, T
    Kaku, Y
    Furuichi, M
    Sakai, N
    NEUROLOGICAL RESEARCH, 2001, 23 (07) : 767 - 771
  • [47] Improved venous suppression and spatial resolution with SENSE in elliptical centric 3D contrast-enhanced MR angiography
    Hu, HCH
    Madhuranthakam, AJ
    Kruger, DG
    Huston, J
    Riederer, SJ
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (04) : 761 - 765
  • [48] Contrast-enhanced 3D MR angiography with simultaneous acquisition of spatial harmonics: A pilot study
    Sodickson, DK
    McKenzie, CA
    Li, W
    Wolff, S
    Manning, WJ
    Edelman, RR
    RADIOLOGY, 2000, 217 (01) : 284 - 289
  • [49] Appropriate Minimal Dose of Gadobutrol for 3D Time-Resolved MRA of the Supra-Aortic Arteries: Comparison with Conventional Single-Phase High-Resolution 3D Contrast-Enhanced MRA
    Bak, S. H.
    Roh, H. G.
    Moon, W. -J.
    Choi, J. W.
    An, H. S.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2017, 38 (07) : 1383 - 1390
  • [50] Intracranial time-resolved contrast-enhanced MR angiography at 3T
    Cashen, TA
    Carr, JC
    Shin, W
    Walker, MT
    Futterer, SF
    Shaibani, A
    McCarthy, FM
    Carroll, TJ
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2006, 27 (04) : 822 - 829