Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA

被引:26
|
作者
Krishnam, M. S. [1 ]
Tomasian, A. [1 ]
Lohan, D. G. [1 ]
Tran, L. [1 ]
Finn, J. P. [1 ]
Ruehm, S. G. [1 ]
机构
[1] Univ Calif Los Angeles, Dept Radiol Sci, Los Angeles, CA 90024 USA
关键词
D O I
10.1016/j.crad.2008.01.001
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
AIM: To evaluate the effectiveness of low-dose, contrast-enhanced, time-resolved, three-dimensional (3D) magnetic resonance (MR) angiography (TR-MRA) in the assessment of various cardiac and vascular diseases, and to compare the results with high-resolution contrast-enhanced MRA (CE-MRA). MATERIALS AND METHODS: Thirty consecutive patients underwent contrast-enhanced 3D TR-MRA and high spatial resolution 3D CE-MRA for evaluation of cardiac and thoracic vascular diseases at 1.5 T, and neurovascular, abdominal and peripheral vascular diseases at 3 T. Gadolinium-based contrast medium was administered at a constant dose of 5 ml for TR-MRA, and 20 ml (lower extremity 30 ml) for CE-MRA. Two readers evaluated image quality using a four-point scale (from 0 = excellent to 3 = non-diagnostic), artefacts and findings on both datasets. Interobserver variability was tested with kappa coefficient. RESULTS: The overall image quality for TR-MRA was in the diagnostic range (median 0, range 0-1; k = 0.74). Readers demonstrated important additional dynamic information on TR-MRA in 28 of 30 patients (k = 0.84). Confident evaluation of organ perfusion (n = 23), arteriovenous malformation/fistula flow patterns (n = 7), exclusion of intra-cardiac shunts (n = 6), and assessment of stent and conduit patency (n = 5) were performed by both readers using TR-MRA. Readers demonstrated fine vascular details with higher confidence in 10 patients on CE-MRA. Using CE-MRA, Reader 1 and 2 depicted anatomical details in 6 and 5 patients, respectively, only on CE-MRA. CONCLUSION: Low-dose TR-MRA yields rapid and important functional and anatomical information in patients with cardiac and vascular diseases. Due to limited spatial resolution, TR-MRA is inferior to CE-MRA in demonstrating fine vascular details. (C) 2008 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:744 / 755
页数:12
相关论文
共 50 条
  • [1] Low-Dose 3D Time-Resolved Magnetic Resonance Angiography (MRA) of the Supraaortic Arteries: Correlation With High Spatial Resolution 3D Contrast-Enhanced MRA
    Lee, Youn-Joo
    Laub, Gerhard
    Jung, So-Lyung
    Yoo, Won-Jong
    Kim, Young-Joo
    Ahn, Kook-Jin
    Kim, Bum-Soo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 33 (01) : 71 - 76
  • [2] Time-resolved, contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    RADIOLOGY, 1996, 201 : 1085 - 1085
  • [3] Time-resolved contrast-enhanced 3D MR angiography
    Korosec, FR
    Frayne, R
    Grist, TM
    Mistretta, CA
    MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) : 345 - 351
  • [4] 1053 Assessment of complex peripheral vascular malformations with highly time-resolved 3D contrast-enhanced MR angiography and single phase high-spatial resolution 3D contrast-enhanced MRA at 3.0 Tesla
    Mayil S Krishnam
    Anderanik Tomasian
    Aparna Singhal
    Stefan G Ruehm
    J Paul Finn
    Antoinette Gomes
    Journal of Cardiovascular Magnetic Resonance, 10 (Suppl 1)
  • [5] Efficacy of time-resolved contrast-enhanced 3D MR angiography of the chest
    Narimatsu, A
    Kurita, K
    Wakiya, M
    Fujita, M
    Ohkawa, T
    Miyazaki, M
    RADIOLOGY, 1999, 213P : 345 - 345
  • [6] Recent advances in 3D time-resolved contrast-enhanced MR angiography
    Riederer, Stephen J.
    Haider, Clifton R.
    Borisch, Eric A.
    Weavers, Paul T.
    Young, Phillip M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (01) : 3 - 22
  • [7] 3D Contrast-enhanced MR angiography
    Zhang, HongLei
    Maki, Jeffrey H.
    Prince, Martin R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 25 (01) : 13 - 25
  • [8] Time-resolved, contrast-enhanced 3D MR angiography in the subclavian steal effect
    Schubert, R.
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2010, 39 (01) : 85 - 93
  • [9] Dose optimization for dynamic time-resolved contrast-enhanced 3D MR angiography of pulmonary circulation
    Sonnet, S
    Buitrago-Téllez, CH
    Schulte, AC
    Bongartz, G
    Bremerich, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (06) : 1499 - 1503
  • [10] Multi-echo technique for time-resolved contrast-enhanced 3D MR angiography
    Vigen, KK
    Mistretta, CA
    Korosec, FR
    Frayne, R
    Grist, TM