Feasibility of pseudocontinuous arterial spin labeling at 7 T with whole-brain coverage

被引:27
|
作者
Ghariq, Eidrees [1 ]
Teeuwisse, Wouter M. [1 ]
Webb, Andrew G. [1 ]
van Osch, Matthias J. P. [1 ]
机构
[1] Leiden Univ Med Ctr LUMC, CJ Gorter Ctr High Field MRI, Dept Radiol, NL-2333 ZA Leiden, Netherlands
关键词
Cerebral blood flow; MRI; Cerebral arteries; Arterial spin labeling; CEREBRAL-BLOOD-FLOW; TIME; EFFICIENCY; INVERSION; OCCLUSION; EXCHANGE; MODEL; FIELD; MRI;
D O I
10.1007/s10334-011-0297-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We studied the feasibility of pseudocontinuous arterial spin labeling (pCASL) at 7 T. Simulations were performed to find the optimal labeling parameters for pCASL, with particular attention to the maximum-allowed specific absorption rate (SAR). Subsequently, pCASL experiments (four volunteers) were performed to find the B1 efficiency at the labeling position with and without high-permittivity pads placed around the head, and to study the optimal labeling duration (four separate volunteers). Finally, feasibility of whole-brain pCASL imaging was tested. Simulations showed that a lower B1 efficiency should be compensated by a lower effective flip angle of the labeling, a moderately shorter labeling duration, and a longer repetition time. B1 efficiency in the internal carotid arteries just below the carotid siphon was approximately 55% and 35% with and without high-permittivity pads, respectively. In vivo experiments showed an optimal labeling duration of 1,500 ms, although longer labeling durations up to 2,500 ms resulted in similar signal-to-noise efficiency. Whole-brain pCASL imaging was demonstrated in a single volunteer. Despite decreased B1 efficiency, sufficient labeling efficiency can be achieved for whole-brain pCASL at 7 T with high-permittivity pads. However, image quality is still limited compared with 3 T, probably due to imaging instabilities, and further research is needed to elucidate this.
引用
收藏
页码:83 / 93
页数:11
相关论文
共 50 条
  • [21] Pseudocontinuous arterial spin labeling perfusion magnetic resonance imaging-A normative study of reproducibility in the human brain
    Wu, Wen-Chau
    Jiang, Shu-Fen
    Yang, Shun-Chung
    Lien, Shu-Hua
    NEUROIMAGE, 2011, 56 (03) : 1244 - 1250
  • [22] Multidelay pseudocontinuous arterial spin labeling to measure blood flow in the head and neck
    Sijtsema, Nienke D.
    Petit, Steven F.
    Verduijn, Gerda M.
    Poot, Dirk H. J.
    Warnert, Esther A. H.
    Hoogeman, Mischa S.
    Hernandez-Tamames, Juan A.
    NMR IN BIOMEDICINE, 2023, 36 (07)
  • [23] Repeatability and Reproducibility of Pseudocontinuous Arterial Spin-Labeling?Measured Brain Perfusion in Healthy Volunteers and Patients with Glioblastoma
    Zhou, Limin
    Udayakumar, Durga
    Wang, Yiming
    Pinho, Marco C.
    Wagner, Benjamin C.
    Youssef, Michael
    Maldjian, Joseph A.
    Madhuranthakam, Ananth J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2025,
  • [24] Pseudocontinuous Arterial Spin Labeling: Clinical Applications and Usefulness in Head and Neck Entities
    Tanaka, Fumine
    Umino, Maki
    Maeda, Masayuki
    Nakayama, Ryohei
    Inoue, Katsuhiro
    Kogue, Ryota
    Obara, Makoto
    Sakuma, Hajime
    CANCERS, 2022, 14 (16)
  • [25] Pseudocontinuous Arterial Spin Labeling with Prospective Motion Correction (PCASL-PROMO)
    Zun, Zungho
    Shankaranarayanan, Ajit
    Zaharchuk, Greg
    MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (04) : 1049 - 1056
  • [26] Vessel-encoded arterial spin-labeling using pseudocontinuous tagging
    Wong, Eric C.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1086 - 1091
  • [27] Coverage of anterior fossa in whole-brain irradiation
    Gripp, S
    Kambergs, J
    Wittkamp, M
    Gerlach, B
    Saleh, A
    Engelbrecht, V
    Cohnen, M
    Scherer, A
    Willers, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2004, 59 (02): : 515 - 520
  • [28] Blood-brain barrier permeability measurement by biexponentially modeling whole-brain arterial spin labeling data with multipleT2-weightings
    Schidlowski, Martin
    Boland, Markus
    Rueber, Theodor
    Stoecker, Tony
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [29] High temporal resolution arterial spin labeling MRI with whole-brain coverage by combining time-encoding with Look-Locker and simultaneous multi-slice imaging
    van der Plas, Merlijn C. E.
    Teeuwisse, Wouter M.
    Schmid, Sophie
    Chappell, Michael
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3734 - 3744
  • [30] Measurement of Cerebral White Matter Perfusion Using Pseudocontinuous Arterial Spin Labeling 3T Magnetic Resonance Imaging - an Experimental and Theoretical Investigation of Feasibility
    Wu, Wen-Chau
    Lin, Shu-Chi
    Wang, Danny J.
    Chen, Kuan-Lin
    Li, Ying-Ding
    PLOS ONE, 2013, 8 (12):