Feasibility of pseudocontinuous arterial spin labeling at 7 T with whole-brain coverage

被引:27
|
作者
Ghariq, Eidrees [1 ]
Teeuwisse, Wouter M. [1 ]
Webb, Andrew G. [1 ]
van Osch, Matthias J. P. [1 ]
机构
[1] Leiden Univ Med Ctr LUMC, CJ Gorter Ctr High Field MRI, Dept Radiol, NL-2333 ZA Leiden, Netherlands
关键词
Cerebral blood flow; MRI; Cerebral arteries; Arterial spin labeling; CEREBRAL-BLOOD-FLOW; TIME; EFFICIENCY; INVERSION; OCCLUSION; EXCHANGE; MODEL; FIELD; MRI;
D O I
10.1007/s10334-011-0297-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We studied the feasibility of pseudocontinuous arterial spin labeling (pCASL) at 7 T. Simulations were performed to find the optimal labeling parameters for pCASL, with particular attention to the maximum-allowed specific absorption rate (SAR). Subsequently, pCASL experiments (four volunteers) were performed to find the B1 efficiency at the labeling position with and without high-permittivity pads placed around the head, and to study the optimal labeling duration (four separate volunteers). Finally, feasibility of whole-brain pCASL imaging was tested. Simulations showed that a lower B1 efficiency should be compensated by a lower effective flip angle of the labeling, a moderately shorter labeling duration, and a longer repetition time. B1 efficiency in the internal carotid arteries just below the carotid siphon was approximately 55% and 35% with and without high-permittivity pads, respectively. In vivo experiments showed an optimal labeling duration of 1,500 ms, although longer labeling durations up to 2,500 ms resulted in similar signal-to-noise efficiency. Whole-brain pCASL imaging was demonstrated in a single volunteer. Despite decreased B1 efficiency, sufficient labeling efficiency can be achieved for whole-brain pCASL at 7 T with high-permittivity pads. However, image quality is still limited compared with 3 T, probably due to imaging instabilities, and further research is needed to elucidate this.
引用
收藏
页码:83 / 93
页数:11
相关论文
共 50 条
  • [1] Feasibility of pseudocontinuous arterial spin labeling at 7 T with whole-brain coverage
    Eidrees Ghariq
    Wouter M. Teeuwisse
    Andrew G. Webb
    Matthias J. P. van Osch
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2012, 25 : 83 - 93
  • [2] Superselective Pseudocontinuous Arterial Spin Labeling
    Helle, Michael
    Norris, David G.
    Ruefer, Susanne
    Alfke, Karsten
    Jansen, Olav
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 777 - 786
  • [3] Assessing Reperfusion With Whole-Brain Arterial Spin Labeling A Noninvasive Alternative to Gadolinium
    Mirasol, Raymond V.
    Bokkers, Reinoud P. H.
    Hernandez, Daymara A.
    Merino, Jose G.
    Luby, Marie
    Warach, Steven
    Latour, Lawrence L.
    STROKE, 2014, 45 (02) : 456 - 461
  • [4] Whole-Brain Arterial Spin Labeling Perfusion MRI in Patients With Acute Stroke
    Bokkers, Reinoud P. H.
    Hernandez, Daymara A.
    Merino, Jose G.
    Mirasol, Raymond V.
    van Osch, Matthias J.
    Hendrikse, Jeroen
    Warach, Steven
    Latour, Lawrence L.
    STROKE, 2012, 43 (05) : 1290 - 1294
  • [5] Measuring the labeling efficiency of pseudocontinuous arterial spin labeling
    Chen, Zhensen
    Zhang, Xingxing
    Yuan, Chun
    Zhao, Xihai
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 77 (05) : 1841 - 1852
  • [6] Estimation of Labeling Efficiency in Pseudocontinuous Arterial Spin Labeling
    Aslan, Sina
    Xu, Feng
    Wang, Peiying L.
    Uh, Jinsoo
    Yezhuvath, Uma S.
    van Osch, Matthias
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (03) : 765 - 771
  • [7] Whole-brain Arterial Spin Labeling Perfusion MR Imaging in Patients With Acute Stroke
    Bokkers, Reinoud P.
    Warach, Steven
    van Osch, Matthias J.
    Duyn, Jeff
    Latour, Lawrence L.
    STROKE, 2010, 41 (04) : E273 - E273
  • [8] fMRI at 7 T: Whole-brain coverage and signal advantages even infratentorially?
    Gizewski, Elke R.
    Forsting, Michael
    de Greiff, Armin
    Maderwald, Stefan
    Timmann, Daginar
    Ladd, Mark E.
    NEUROIMAGE, 2007, 37 (03) : 761 - 768
  • [9] Chronic intracranial artery stenosis: Comparison of whole-brain arterial spin labeling with CT perfusion
    Tian, Bing
    Liu, Qi
    Wang, Xinrui
    Chen, Shiyue
    Xu, Bing
    Zhu, Chengcheng
    Lu, Jianping
    CLINICAL IMAGING, 2018, 52 : 252 - 259
  • [10] Pseudocontinuous arterial spin labeling with optimized tagging efficiency
    Shin, David D.
    Liu, Thomas T.
    Wong, Eric C.
    Shankaranarayanan, Ajit
    Jung, Youngkyoo
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (04) : 1135 - 1144