SYNTHESIS AND STUDY ON MAGNETIC RESONANCE IMAGING PERFORMANCE OF GD(III)-DTPA-BISBENZOTHIAZOL HYDRAZIDE

被引:0
|
作者
Wan, Fu-Xian [1 ]
Zhang, Tian-Kai [1 ]
Li, Ying [1 ]
Li, Chang-Cheng [1 ]
Jiang, Lin [1 ]
机构
[1] Shan Dong Agr Univ, Coll Chem & Mat Sci, Tai An 271018, Shandong, Peoples R China
来源
关键词
MRI contrast agent; benzothiazole; DTPA derivative; gadolinium complex; relaxivity; NEUTRON-CAPTURE THERAPY; MRI CONTRAST AGENTS; BIOLOGICAL EVALUATION; GADOLINIUM COMPLEX; RELAXATION; ACID; BENZOTHIAZOLE; MANGANESE(II); DERIVATIVES; CHELATORS;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In this paper, 2-hydrazino-6-methoxy-1,3-benzothiazole was introduced into diethylenetriamine pentaacetic (DTPA) by acylation reaction. The corresponding non-ion Gd(III) complex holding promise of a single molecule magnetic resonance imaging (MRI) contrast agent was obtained by treating this ligand with GdCl3 center dot 6H(2)O. The efficacy of the contrast agent was assessed by measuring the longitudinal relaxivity (r(1)), the r(1) of Gd(III)-DTPA-bisbenzothiazole hydrazide was up to 6.44 mM(-1).s(-1), which was 1.8 times higher than that of the analogous MRI contrast agent Gd(III)-DTPA(r(1) = 3.64 mM(-1).s(-1)) in commercial use. In addition, in vitro MR images on a 0.5 T magnetic field exhibited a remarkable enhancement of signal contrast for Gd(III)-DTPA-bisbenzothiazole hydrazide than Gd(III)-DTPA. These results demonstrate that this non-ion Gd(III) complex acts as a potentially MRI contrast agent.
引用
收藏
页码:2861 / 2863
页数:3
相关论文
共 50 条
  • [31] Magnetic resonance dacryocystography: Use of topic Gd-DTPA
    Manfre, L
    Mangiameli, A
    Banco, A
    Caronia, A
    D'Antonio, V
    Lagalla, R
    RADIOLOGY, 1998, 209P : 347 - 347
  • [32] Functional magnetic resonance cholangiography with Gd-EOB-DTPA: A study in healthy volunteers
    Lee, Seung Wha
    Cha, Sang Hoon
    Chung, Hwan Hoon
    Kim, Kee Hwan
    Yeom, Suk Keu
    Seo, Bo Kyung
    Je, Bo Kyung
    Kim, Baek Hyun
    MAGNETIC RESONANCE IMAGING, 2014, 32 (04) : 385 - 391
  • [33] THE SYNTHESIS AND SCREENING OF NONIONIC GADOLINIUM(III) DTPA-BISAMIDE COMPLEXES AS MAGNETIC-RESONANCE-IMAGING CONTRAST AGENTS
    PERIASAMY, M
    WHITE, D
    DELEARIE, L
    MOORE, D
    WALLACE, R
    LIN, W
    DUNN, J
    HIRTH, W
    CACHERIS, W
    PILCHER, G
    GALEN, K
    HYNES, M
    BOSWORTH, M
    LIN, H
    ADAMS, M
    INVESTIGATIVE RADIOLOGY, 1991, 26 : S217 - S220
  • [34] Synthesis and Characterization of Amphiphilic Gd(III) Complexes: Gd-DTPA-BA
    Zhao, Zheng
    Fang, Hui
    Qiao, Weihong
    JOURNAL OF SURFACTANTS AND DETERGENTS, 2018, 21 (04) : 601 - 607
  • [35] Comparison of the efficacy of Gd-EOB-DTPA-enhanced magnetic resonance imaging and magnetic resonance elastography in the detection and staging of hepatic fibrosis
    Wu, Wen-Pei
    Hoi, Cheng-In
    Chen, Ran-Chou
    Lin, Ching-Po
    Chou, Chen-Te
    MEDICINE, 2017, 96 (42)
  • [36] Delayed magnetic resonance imaging with Gd-DTPA differentiates subdural hygroma and subdural effusion - Commentary
    Mafee, MF
    SURGICAL NEUROLOGY, 2000, 53 (04): : 310 - 311
  • [37] CLINICAL UTILITY OF GD-DTPA ENHANCED MAGNETIC-RESONANCE-IMAGING IN LUNG-CANCER
    KONO, M
    ADACHI, S
    KUSUMOTO, M
    SAKAI, E
    JOURNAL OF THORACIC IMAGING, 1993, 8 (01) : 18 - 26
  • [38] CRANIOSPINAL MAGNETIC-RESONANCE-IMAGING ENHANCED WITH GD-DTPA IN VONHIPPEL-LINDAU DISEASE
    HARDJASUDARMA, M
    FOWLER, M
    JOURNAL OF THE CANADIAN ASSOCIATION OF RADIOLOGISTS-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1991, 42 (04): : 283 - 286
  • [39] NEW MAGNETIC-RESONANCE-IMAGING CONTRAST AGENTS FOR INFARCT IMAGING BASED ON PHOSPHONATE DERIVATIVES OF GD-DTPA
    ADZAMLI, IK
    BLAU, M
    PFEFFER, MA
    DAVIS, MA
    INVESTIGATIVE RADIOLOGY, 1991, 26 : S242 - S244
  • [40] Gd-EOB-DTPA-Enhanced Magnetic Resonance Imaging Findings of Nondiffuse Fatty Change of the Liver
    Yamamoto, Akira
    Tamada, Tsutomu
    Sone, Teruki
    Higashi, Hiroki
    Yamashita, Takenori
    Ito, Katsuyoshi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2010, 34 (06) : 868 - 873