Loading of transformers in conditions of controlled cooling system

被引:13
|
作者
Radakovic, Zoran [1 ]
Jacic, Dusan [1 ]
Lukic, Jelena [2 ]
Milosavljevic, Srdjan [2 ]
机构
[1] Univ Belgrade, Fac Elect Engn, Belgrade, Serbia
[2] Inst Nikola Tesla, Belgrade, Serbia
关键词
transformer loading; fouling of transformer coolers; automatic control of transformer cooling system; monitoring of power transformer; POWER TRANSFORMERS; TEMPERATURES;
D O I
10.1002/etep.1688
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The paper deals with thermal modelling of transformers with automatic control of the cooling system. The case study was done on 725 MVA transformer with OFAF cooling, having eight compact coolers, each of them with their own pump and hysteresis control: four coolers, when top oil temperature drops below 30 degrees C, and six coolers, when top oil temperature rises above 45 degrees C. The consequence of operation with different number of coolers is change of thermal characteristics of the transformer. Additional phenomenon causing change of thermal characteristics is fouling of the coolers. These variable thermal characteristics are included in mathematical models used for the calculation of top oil and hot-spot temperatures in all applications of such calculation algorithms: protection, monitoring, estimation of overload capability, calculation of thermal ageing, etc. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:203 / 214
页数:12
相关论文
共 50 条
  • [21] Cooling System Oil-Immersed Transformers with the Use of a Circulating Sulfur Hexafluoride
    Bashirov, M. G.
    Khismatullin, A. S.
    Sirotina, E., V
    ADVANCES IN AUTOMATION, 2020, 641 : 613 - 621
  • [22] Prioritizing the Restoration of Network Transformers Using Distribution System Loading and Reliability Indices
    Hardowar, Roupchan
    Rodriguez, Sergio
    Uosef, Resk Ebrahem
    de Leon, Francisco
    Czarkowski, Dariusz
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (03) : 1236 - 1243
  • [23] Optimisation of operating conditions of a vacuum cooling system for cooling cooked meats
    Wang, LJ
    Sun, DW
    INTERNATIONAL SYMPOSIUM ON APPLICATIONS OF MODELLING AS AN INNOVATIVE TECHNOLOGY IN THE AGRI-FOOD-CHAIN - MODEL-IT, 2001, (566): : 407 - 413
  • [24] Development of a Controlled Rate Cooling System for Cryopreservation
    Chen, Hsiuhung
    Shu, Zhiquan
    Gao, Dayong
    Proceedings of the 3rd Frontiers in Biomedical Devices Conference - 2008, 2008, : 87 - 88
  • [25] A SYSTEM FOR CONTROLLED LINEAR COOLING OF LABORATORY FURNACES
    LOMAS, TW
    FINCH, LG
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1957, 34 (03): : 118 - 120
  • [27] Controlled switching of transformers
    Lazarev N.S.
    Shul'Ga A.R.
    Shul'Ga R.N.
    Russian Electrical Engineering, 2011, 82 (7) : 365 - 370
  • [28] CLIMATIC CONDITIONS FOR DESIGNING HEATING/COOLING SYSTEM
    Sleger, Vladimir
    Neuberger, Pavel
    Polak, Martin
    TRENDS IN AGRICULTURAL ENGINEERING 2010, 2010, : 594 - 597
  • [29] Diagnostics of the cooling systems in the power transformers
    Borowik, Lech
    Wlodarz, Rajmund
    PRZEGLAD ELEKTROTECHNICZNY, 2011, 87 (06): : 206 - 208
  • [30] Rational Loading on Combined Waste Heat Recovery Cooling System
    Radchenko, Andrii
    Forduy, Serhiy
    Kantor, Serhiy
    Zelikov, Oleksii
    Khaldobin, Viktor
    ADVANCED MANUFACTURING PROCESSES III, INTERPARTNER-2021, 2022, : 634 - 643